Installation of a MIDEA EVOX G3 3 Ton Central Heat Pump in Chomedey, Laval

HVAC installation in Laval of a MIDEA EVOX G3 3-ton central heat pump. Optimal comfort, energy savings, available subsidies, and recognized AirGreen expertise.

By AirGreen Climatisation & Chauffage Admin5 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
5 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a MIDEA EVOX G3 3 Ton Central Heat Pump in Chomedey, Laval
Installation of a MIDEA EVOX G3 3 Ton Central Heat Pump in Chomedey, Laval
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Midea EVOX G3 · 1.5 tons14,70018,600−30 °C: 11,8002.1219.010.1$1,764
Midea EVOX G3 · 2 tons20,80020,600−30 °C: 12,1002.1418.610.0$2,496
Midea EVOX G3 · 2.5 tons24,00033,200−30 °C: 17,9001.9717.210.8$2,880
Midea EVOX G3 · 3 tons33,00037,400−30 °C: 27,6001.918.010.0$3,960
Midea EVOX G3 · 4 tons39,50048,000−30 °C: 27,2002.017.59.5$4,740
Midea EVOX G3 · 5 tons45,00054,000−30 °C: 37,3001.917.59.5$5,400

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

Strategic HVAC Modernization for Consistent All-Season Comfort

In the residential sector of Chomedey in Laval, we recently completed a full HVAC installation of a MIDEA EVOX G3 3-ton central heat pump in a single-family home built in the 1990s. The owner wanted to replace an old, inefficient system combining an electric furnace and an aging central air conditioner, which had become expensive to operate and unable to maintain a stable temperature.

At AirGreen, we managed the entire project, from initial assessment to final commissioning, including optimizing the existing ducts. This project perfectly illustrates our approach: technical precision, energy efficiency, and adaptation to the climatic realities of Greater Montreal, Laval, and the North Shore.


Why the MIDEA EVOX G3 Was the Ideal Choice for This Residence

Perfectly Adapted Power: 36,000 BTU (3 tons)

After a complete thermal analysis of the building (area, insulation, orientation, air volume), we determined that a capacity of 36,000 BTU was ideal to ensure:

  • Homogeneous heat distribution
  • Rapid cooling in summer
  • Stable performance even during cold snaps

Guaranteed Performance Down to -30°C

One of the decisive criteria for this client was winter reliability. The MIDEA EVOX G3 stands out for:

  • Heating capacity down to -30°C
  • Performance maintained at -25°C without major loss
  • Inverter technology allowing intelligent modulation

Result: consistent heat, without abrupt cycles or discomfort.


Technical Challenges Encountered During Installation in Chomedey

Restricted Access to the Outdoor Location

The outdoor unit had to be installed on a narrow side of the house, with:

  • Limited clearance
  • Proximity to the foundation
  • Optimized drainage

AirGreen Solution:

  • Installation on a raised aluminum support
  • Precise leveling to avoid vibrations
  • Optimized drainage to prevent water accumulation

Reuse of Existing Ducts

The duct system was functional but required adjustments:

  • Complete cleaning
  • Sealing of joints
  • Airflow verification

We also validated compatibility with the Computational Constant Airflow 2.0 system, ensuring optimal air circulation.


Complete Technical Details of the Installed MIDEA EVOX G3

  • Capacity: 3 tons (36,000 BTU)
  • SEER2: 17.7
  • HSPF2: 10.0
  • EER2: 12.0
  • Refrigerant: R-454B (low environmental impact)
  • Voltage: 220V
  • Outdoor sound level: 62.5 dB(A)
  • WiFi: Included
  • Piping: 3/8 – 3/4

Certification and Energy Efficiency

  • ENERGY STAR® certified
  • Cold Climate ENERGY STAR® recognition

This type of performance is particularly sought after by homeowners in Laval, Montreal, and the South Shore, who are keen to reduce their energy consumption.


Available Grant: A Major Financial Advantage

For this installation in Chomedey, the client benefited from the LogisVert grant:

  • Amount: up to $3,720
  • Simple process with invoice provided
  • Full assistance from our team

At AirGreen, we systematically support our clients in these procedures to maximize their return on investment.


Full Installation Process

1. On-site Evaluation

We analyzed:

  • The condition of the existing system
  • The duct configuration
  • Specific thermal needs

2. Site Preparation

  • Protection of work areas
  • Planning for piping routes
  • Electrical preparation

3. Outdoor Unit Installation

  • Mounting on a stable support
  • Refrigerant connection
  • Pressure verification

4. Indoor Unit Installation

  • Optimal positioning in the mechanical room
  • Duct connection
  • Airflow calibration

5. Commissioning and Testing

  • Vacuum test (micron test)
  • Performance verification
  • WiFi and thermostat configuration

Concrete Results for the Client

From the very first days of use, the client observed:

  • A noticeable reduction in energy costs
  • A stable temperature in all rooms
  • Quiet operation
  • Improved air quality

After a few weeks, the feedback was clear: the overall comfort of the home had been transformed.


Practical Advice for Homeowners in Laval and Montreal

Choosing the Right Capacity

An undersized heat pump leads to:

  • Overconsumption
  • Premature wear
  • Thermal discomfort

Always perform a professional analysis.

Don't Neglect the Ducts

Even the best machine will not perform without:

  • Sealed ducts
  • Balanced airflow

Consider HVAC Maintenance

To maximize lifespan:

  • Annual cleaning
  • Filter check (MERV 13 recommended)
  • Professional inspection

Why Choose AirGreen for Your HVAC Installation

At AirGreen, we distinguish ourselves by:

  • Real expertise in central heat pump installation
  • In-depth knowledge of the climatic realities of Montreal, Laval, Longueuil, North Shore, and South Shore
  • Total transparency in our quotes
  • Fast and reliable after-sales service

Every project is handled with rigor, precision, and attention to detail.


A Sustainable Investment for Your Comfort

Installing a MIDEA EVOX G3 central heat pump represents much more than just equipment replacement:

  • Reduced energy costs
  • Improved comfort
  • Property value enhancement
  • Reduced environmental footprint

For homeowners in Chomedey, Laval, and the surrounding areas, it's a perfectly adapted solution for Quebec winters.


Conclusion

This installation in Chomedey clearly demonstrates that a well-chosen and correctly installed system can transform the comfort of a home. The MIDEA EVOX G3 3-ton emerges as a reliable, high-performance, and durable solution for Quebec residences.

At AirGreen, we continue to support our clients with tailor-made solutions, adapted to their real needs and the demands of the local climate.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

    1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
    2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
    3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
    4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
    5. The outdoor unitOn a level base, raised above the snow, with free space all around.
    6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
    7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
    8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
    9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: central heat pump, indoor module and ducts

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

    2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

    3. A shut-off switch near the outdoor unit isolates it safely for service.

    4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

    5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

    6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

    7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

    8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment