Installation d’une thermopompe double zone FUJITSU Aquila R32 36 000 BTU à Saint-Bruno
Reading time: 4'

Installation of a FUJITSU Aquila R32 36,000 BTU dual-zone heat pump in Saint-Bruno

Precise and Durable HVAC Installation for Optimal Comfort on the South Shore

At AirGreen, we regularly perform HVAC installations on the South Shore, particularly in Saint-Bruno, where thermal comfort requirements are high due to significant climatic variations. This project highlights the installation of a FUJITSU Aquila R32 36,000 BTU dual-zone heat pump (outdoor model AOUH36KWAS4), a solution perfectly suited for a residence requiring independent management of two distinct areas.

A Dual-Zone Configuration Perfectly Adapted to the Client's Needs

On-site Needs Analysis

During our technical visit to Saint-Bruno, the client wanted to improve the thermal comfort of two main zones:

  • An open living space (living room + kitchen)
  • A more isolated zone upstairs (master bedroom)

The main constraint was to maintain a stable and independent temperature in these two zones, without resorting to an expensive and invasive central system.

Chosen Solution: FUJITSU Aquila DualZone

We recommended a FUJITSU Aquila R32 36,000 BTU heat pump, configured in dual-zone with:

  • A 24,000 BTU indoor unit for the main area
  • A 12,000 BTU indoor unit for the upstairs

This combination provides a perfect balance of power, efficiency, and comfort.

Technical Details of the Installed Heat Pump

Performance and Energy Efficiency

The FUJITSU Aquila R32 heat pump stands out for its reliable performance in Quebec conditions:

  • Cooling capacity: 36,000 BTU
  • Heating capacity down to -15°C
  • SEER2: 22.0
  • HSPF2: 10.0
  • EER2: 12.0
  • R-32 refrigerant: more ecological and efficient

Although this model is not Cold Climate ENERGY STAR certified, it offers excellent performance for much of the year, particularly for air conditioning and moderate heating.

Design and Durability

  • INVERTER compressor for intelligent modulation
  • Blue Fin exchanger against corrosion
  • Outdoor sound level: 56 dB(A) (ideal for a residential neighborhood like Saint-Bruno)
  • Voltage: 220V

Installation Review: AirGreen's Precision and Rigor

Outdoor Unit Installation

As visible on site, we installed the outdoor unit on elevated wall mounts with anti-vibration dampers. This choice offers several advantages:

  • Protection against snow accumulation in winter
  • Reduction of vibrations transmitted to the structure
  • Better air circulation under the unit

We also ensured:

  • Compliance with recommended minimum distances
  • Perfect alignment with the facade
  • Efficient drainage installation

Refrigerant Line Management

A crucial point in any heat pump installation is the quality of the piping:

  • Use of high-performance insulated conduits
  • Discrete routing along the exterior wall
  • Protection against UV and bad weather

We performed a complete vacuum (micron test) to guarantee the absence of humidity and micro-leaks, thus ensuring the longevity of the system.

Indoor Unit Installation

Each indoor unit was strategically positioned to:

  • Maximize air diffusion
  • Avoid dead zones
  • Minimize perceived noise

The wall brackets were reinforced to ensure perfect stability.

Challenges Encountered and Solutions Provided

Restricted Outdoor Space

The backyard had limited space, with restricted access. We opted for:

  • A compact installation against the wall
  • Precise positioning planning to facilitate future maintenance

Aesthetic Integration

The client wanted a discreet installation. Therefore, we:

  • Aligned the conduits with the architectural lines of the house
  • Used pipe covers matching the facade

Subsidies and Profitability

This installation is eligible for the LogisVert subsidy, with an amount of approximately $1,180 (according to the latest updates).

Financial Impact

  • Reduction of initial cost
  • Significant long-term energy savings
  • Accelerated return on investment

Practical Tips for Homeowners in Montreal, Laval, Longueuil, North Shore, and South Shore

Choosing the Right Heat Pump

  • Match power to actual needs (avoid oversizing)
  • Prioritize reputable brands like Fujitsu
  • Check eligibility for subsidies

Importance of Installation

Even the best machine can underperform if poorly installed. At AirGreen:

  • Our refrigeration technicians are certified and experienced
  • We follow strict procedures (vacuuming, testing, calibration)
  • We guarantee compliant and durable installation

Regular HVAC Maintenance

Annual HVAC maintenance allows for:

  • Maintaining energy efficiency
  • Extending the heat pump's lifespan
  • Preventing costly breakdowns

Why Choose AirGreen for Your Installation in Saint-Bruno

We distinguish ourselves by:

  • Proven field expertise in Montreal, Laval, Longueuil, South Shore, and North Shore
  • Clean, durable, and optimized installations
  • Total transparency: no payment until complete satisfaction
  • Personalized support from start to finish

Each project is handled with rigor, as if it were for our own home.

Conclusion: A Reliable, High-Performance, and Long-Lasting Installation

This installation of a FUJITSU Aquila R32 dual-zone 36,000 BTU heat pump in Saint-Bruno perfectly illustrates our approach: precise analysis, strategic equipment choice, impeccable installation.

The result is a quiet, efficient, and perfectly integrated system, offering consistent comfort throughout the home.

At AirGreen, we don't just install HVAC systems—we ensure their long-term performance.