Installation of a GREE LIVO R32 Wall-Mounted Heat Pump – Mini Split Air Conditioner in Sainte-Rose, Laval
AirGreen installs a GREE LIVO R32 wall-mounted heat pump in Sainte-Rose, Laval: discreet mini split, efficient air conditioning, careful HVAC installation, and lasting comfort.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A wall-mounted heat pump precisely installed on an accent wall in Sainte-Rose
In Sainte-Rose, in northern Laval, our AirGreen team carried out the installation of a wall-mounted heat pump GREE LIVO R32, a mini split system designed to provide effective comfort in both cooling and heating modes. This installation stands out immediately by its location: the indoor unit was placed on an orange accent wall, near the ceiling, in a room under development where the visual finish had to remain clean despite technical constraints.
The image shows a white GREE unit, well centered on the wall, installed at a strategic height to free up floor space and promote good air distribution. The contrast between the white casing of the wall-mounted heat pump and the bright color of the wall made alignment particularly important. On a colored surface, even the slightest misalignment becomes much more visible. That is why our team took the time to validate the height, level, position relative to the ceiling, and distance from adjacent walls before finalizing the installation.
In a project like this, the challenge is not only to mount the device. It is also necessary to understand how the air will circulate in the room, how the unit can be maintained, how the refrigerant lines will be routed, and how the installation will fit into the existing space without creating too heavy a visual impact.
Why the GREE LIVO R32 model was well suited for this room
The GREE LIVO R32 is a wall-mounted solution appreciated for residential installations where the client seeks a reliable, compact, and easy-to-use device. In this residence in Sainte-Rose, the choice of this system met several needs: improving the comfort of a main room, reducing heat in summer, providing supplemental heating during cooler periods, and avoiding portable devices or window air conditioners that clutter the space.
The refrigerant R32 is one of the important elements of this range. It is used in several recent wall air conditioner and mini split heat pump systems to meet current efficiency and environmental responsibility requirements. For an owner in Laval, this means more modern equipment, better suited to current HVAC market expectations.
The practical advantages of this installation include:
- a compact wall unit that takes up no floor space;
- an efficient air conditioning mode for hot days;
- a heating mode useful during intermediate seasons;
- adjustable air distribution thanks to adjustable louvers;
- a sober appearance that contrasts neatly with the colored wall;
- simple daily use;
- a solution adapted to houses, condos, and apartments in Laval.
The exact BTU capacity always depends on the installed combination and the building configuration. At AirGreen, we avoid recommending capacity based solely on surface area. We also analyze ceiling height, insulation, solar orientation, openings, heat loss, and usage habits. This analysis allows us to choose a heat pump capable of operating efficiently without too short cycles or excessive strain.
An accent wall that required a flawless finish
Installing a white unit on an orange wall creates a strong contrast. This results in an interesting visual effect when the work is clean, but it also leaves little room for error. The lines must be straight, the drillings must be precise, and the wall plate must be perfectly fixed.
In this installation in Sainte-Rose, our team paid special attention to aligning the indoor unit with the ceiling. The top of the device is close to the ceiling line, which requires careful installation. A slightly tilted unit would have been immediately noticeable. The goal was to maintain a clean appearance while respecting the clearances necessary for the proper functioning of the device.
We also took into account the presence of furniture under the unit and the future use of the room. A successful HVAC installation must remain practical after the technicians leave. It must be possible to access the filters, clean the unit, adjust the louvers, and enjoy comfort without the airflow being blocked by furniture, a curtain, or a decorative element.
A high installation for better air diffusion
High placement is common for a wall-mounted heat pump, but it should never be improvised. Warm air tends to rise, while cold air descends. The unit's positioning must therefore take this natural movement into account to achieve a more stable temperature in the room.
In this project, the GREE unit was installed to diffuse air toward the living space rather than directly toward an obstacle. This decision helps reduce uncomfortable zones and improve the distribution of cooling or heating. The adjustable louvers of the GREE LIVO R32 then allow adjusting the blowing direction according to the season.
In cooling mode, the air can be directed to gradually cool the room without creating a too intense direct draft. In heating mode, adjusting the louvers helps push the air downward to better distribute the heat. These details seem simple, but they greatly change the customer's daily experience.
The technical steps behind a clean installation
The photo shows the final result, but a large part of the work lies in the invisible steps. Before commissioning, a mini split heat pump requires a series of essential checks.
Our team notably validated:
- the strength of the wall and the support;
- the level of the mounting plate;
- the location of the drilling;
- the passage of refrigerant lines;
- the condensation drainage;
- the tightness of the fittings;
- the vacuuming of the circuit;
- the compliant electrical connection;
- the operation of basic modes;
- air diffusion after startup.
These steps are fundamental. An indoor unit may seem well installed, but if the drain is poorly sloped, if the fittings are poorly tightened, if the vacuuming is neglected, or if the unit is not stable, the client may encounter problems later. At AirGreen, we give as much importance to what is seen as to what is unseen.
Practical lessons from this HVAC installation in Laval
Drainage: an essential point to protect the interior wall
In cooling and dehumidification mode, a wall heat pump produces condensation. This water must be properly drained. On a colored wall like this one, a leak or internal flow could quickly leave visible marks. Drainage was therefore a priority point.
A poorly installed drain can cause several problems:
- water leakage under the unit;
- marks on the wall;
- humidity odors;
- noise in the drain;
- water accumulation in the tray;
- avoidable service calls;
- discomfort for the client.
Our team therefore checked the slope and drainage before finalizing the startup. This type of check is part of a true professional wall air conditioner installation.
The choice of location: a decision that influences the following years
The indoor unit was placed in the upper part of the wall, which allows keeping the floor space usable. This decision is particularly important in rooms where the layout may change. The client will be able to move or replace the furniture under the unit without compromising the system's operation, provided that clear air circulation is maintained.
A good location must meet several criteria:
- promote air diffusion;
- remain accessible for maintenance;
- limit visual impact;
- respect the manufacturer's clearances;
- allow reliable drainage;
- facilitate the passage of pipes;
- avoid direct blowing on occupants;
- take into account current and future furniture.
In several houses in Sainte-Rose, the rooms have been renovated over time. The walls, ceilings, windows, and interior fittings do not always follow a standard logic. That is why an evaluation visit is essential before recommending a final location.
Subsidies and eligibility: a check to do with the exact model
Owners in Montreal, Laval, Longueuil, the North Shore, and the South Shore often ask if their wall-mounted heat pump is eligible for a subsidy. Programs like Hydro-Québec's LogisVert can reduce the final cost of a project, but eligibility depends on the exact installed combination, certified performance, and criteria in effect at the time of application.
For a GREE LIVO R32, always verify the indoor and outdoor model numbers, BTU capacity, applicable efficiencies, and official documentation. AirGreen assists customers in this verification to provide clear information and avoid unpleasant surprises.
The price of an installation should never be evaluated solely based on the amount shown on the quote. You should also consider:
- installation quality;
- drainage reliability;
- compliance with standards;
- the warranty;
- energy efficiency;
- potential eligibility for subsidies;
- after-sales service;
- the availability of parts;
- the reputation of the installer.
Mistakes to avoid with a GREE LIVO R32 wall-mounted heat pump
An installation like this may seem simple once completed, but several mistakes can reduce system performance.
Installing the device too close to the ceiling without checking the air return
The proximity to the ceiling must be carefully evaluated. Insufficient clearance can hinder air circulation and make the device less efficient.
Neglecting furniture under the unit
A piece of furniture that is too tall or too close can hinder air distribution. It can also complicate access to the filters.
Choosing a BTU capacity without a complete analysis
Surface area alone is not enough. A sunny room, poorly insulated or open to another space, can have very different needs.
Forgetting filter maintenance
A dirty filter reduces air circulation, increases system effort, and decreases comfort. Regular HVAC maintenance helps preserve performance.
Entrusting the installation to an unqualified person
Handling refrigerants, refrigeration connections, and commissioning must be carried out by qualified professionals. Poor installation can negate the benefits of a good device.
Usage tips to maximize comfort
After starting this GREE LIVO R32 wall-mounted heat pump, we explained to the client the best usage practices. To achieve stable comfort, it is better to maintain a reasonable temperature rather than constantly turning the unit off and on. In cooling mode, this also helps better control humidity.
The louvers should be adjusted according to the season. In summer, indirect diffusion helps cool the room without creating unpleasant drafts. When heating, it is better to direct the air to better distribute warmth in the occupied area.
Filters must be cleaned regularly, especially in an active room or during renovation periods. Dust can quickly accumulate on surfaces and inside the unit. Simple cleaning, done at the right time, helps maintain good airflow.
A representative project of AirGreen’s work in Sainte-Rose
This installation in Sainte-Rose clearly illustrates our approach: choosing the right location, respecting technical constraints, protecting the room’s appearance, and delivering a reliable solution. The GREE LIVO R32 fits here into a colorful space where visual finish was as important as performance.
AirGreen regularly serves Laval, Montreal, Longueuil, the North Shore, and the South Shore for projects involving wall-mounted heat pumps, wall air conditioners, mini splits, residential installation, and HVAC maintenance. Each home has its own constraints, and this is precisely where field experience makes the difference.
In this project, the installed unit now offers a discreet, efficient, and room-appropriate comfort solution. The client benefits from a modern system, well positioned, easy to use, and ready to improve daily comfort, both in summer and cold seasons.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Gree Livo R32 9 000 (115 V) | 10,000 | 7,600 | −25 °C: 5,700 | 1.86 | 20.5 | 8.8 | – |
| Gree Livo R32 9 000 | 9,600 | 7,600 | −25 °C: 5,500 | 1.94 | 20.5 | 8.8 | – |
| Gree Livo R32 12 000 (115 V) | 9,700 | 8,500 | −25 °C: 6,500 | 1.75 | 19.0 | 8.5 | – |
| Gree Livo R32 12 000 | 9,700 | 9,100 | −25 °C: 6,500 | 1.8 | 19.0 | 8.5 | $1,164 |
| Gree Livo R32 18 000 | 15,300 | 12,100 | −25 °C: 10,200 | 1.85 | 20.0 | 8.5 | $1,836 |
| Gree Livo R32 24 000 | 19,200 | 15,700 | −25 °C: 10,500 | 1.75 | 19.0 | 8.5 | $2,304 |
| Gree Livo R32 30 000 | 24,000 | 23,000 | −25 °C: 16,900 | 1.8 | 22.0 | 9.0 | $2,880 |
| Gree Livo R32 36 000 | 27,400 | 24,600 | −25 °C: 21,000 | 1.8 | 21.0 | 8.5 | $3,288 |
According to NEEP, it delivers 10,000 BTU/h at −8 °C (17 °F), as much as at 8 °C. It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −25 °C (−13 °F) is 5,700 BTU/h, 63% of its nominal 9,000 BTU size.
At 8 °C, its certified maximum capacity reaches 13,300 BTU/h, 48% more than its nominal 9,000 BTU size.
According to NEEP, its COP at −15 °C is 1.94: the highest of the Livo R32 line, which ranges from 1.75 to 1.86 at that temperature.
According to NEEP, its certified maximum capacity at −25 °C (−13 °F) is 5,500 BTU/h, 61% of its nominal 9,000 BTU size.
At 8 °C, its certified maximum capacity reaches 13,136 BTU/h, 46% more than its nominal 9,000 BTU size.
According to NEEP, it delivers 8,500 BTU/h at −15 °C, against 9,100 for the Gree Livo R32 12 000.
At −25 °C, its certified minimum capacity is 1,800 BTU/h (3,070 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 8,500 BTU/h, 71% of its nominal 12,000 BTU size. Its COP there is 1.75.
According to NEEP, it delivers 9,100 BTU/h at −15 °C, against 8,500 for the Gree Livo R32 12 000 (115 V).
At −25 °C, its certified minimum capacity is 1,800 BTU/h (3,070 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 9,100 BTU/h, 76% of its nominal 12,000 BTU size. Its COP there is 1.80.
At 8 °C, its certified maximum capacity reaches 22,500 BTU/h, 25% more than its nominal 18,000 BTU size.
According to NEEP, its certified minimum capacity is at least 7,000 BTU/h at every temperature. In a small, well-insulated room it will cycle on and off more often: size it carefully.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 12,100 BTU/h, 67% of its nominal 18,000 BTU size. Its COP there is 1.85.
At −25 °C, its certified minimum capacity is 3,100 BTU/h (5,800 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 15,700 BTU/h, 65% of its nominal 24,000 BTU size. Its COP there is 1.75.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 23,000 BTU/h, 77% of its nominal 30,000 BTU size. Its COP there is 1.80.
According to NEEP, its COP at −25 °C is 1.54: the highest of the Livo R32 line, which ranges from 1.30 to 1.52 at that temperature.
At −25 °C, its certified minimum capacity is 7,000 BTU/h (10,000 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 24,600 BTU/h, 68% of its nominal 36,000 BTU size. Its COP there is 1.80.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.A dash in the aid column: amount to be confirmed for this model.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).