Installation of a SHARP ZU1 24,000 BTU Mini Split Heat Pump in Montréal-Nord
AirGreen’s SHARP ZU1 Mini Split installation in Montréal-Nord delivers eco-friendly comfort with advanced Plasmacluster air purification and superior heating in sub-zero temperatures.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Advanced Climate Control for Unpredictable Winters and Hot Summers
In the heart of Montréal-Nord, our team at AirGreen recently completed a top-tier installation of the SHARP ZU1 24,000 BTU Mini Split Heat Pump. This isn’t just any HVAC system; it’s a unit designed to withstand the demanding climate of Quebec, delivering year-round comfort, superior efficiency, and air quality improvements that go beyond mere temperature control. From its sleek design to its advanced capabilities, this SHARP model has been meticulously chosen for its powerful performance, eco-friendliness, and smart technology that resonates with modern homeowners.
The Perfect Choice for Montréal's Climate Extremes
With Montreal’s unpredictable weather swings, a reliable heating and cooling solution is essential. The SHARP ZU1 Mini Split Heat Pump stands out for its cooling capacity of 24,000 BTU and a heating range that goes down to -27°C, making it ideal for our cold Canadian winters and humid summers. This specific unit is eligible for Hydro-Québec’s highest LogisVert Grant, amounting to a generous $2,688—a testament to its energy efficiency and eco-conscious design.
Key Features That Make the SHARP ZU1 Exceptional
-
Advanced Plasmacluster Technology: Known for its ability to purify the air, this system generates positive and negative ions, which neutralize airborne contaminants, allergens, and even viruses. This feature ensures a healthier indoor environment, perfect for households prioritizing air quality.
-
High Efficiency and Quiet Operation: With an energy efficiency rating of 22.0 SEER, the SHARP ZU1 is one of the most efficient models on the market, helping homeowners cut down on energy bills while minimizing environmental impact. Its sound pressure levels are remarkably low—53 dB(A) for the exterior and a variable range of 25 to 49 dB(A) inside—ensuring a quiet, serene environment without the typical hum of older HVAC units.
-
Smart, WiFi-Enabled Control: Homeowners can control this system remotely, thanks to the built-in WiFi. Adjusting the temperature from anywhere in the house or even outside is a breeze, adding convenience and flexibility to everyday life.
-
Durable Design with R-32 Refrigerant: The SHARP ZU1 uses R-32 refrigerant, known for its lower environmental impact compared to traditional options. Additionally, the unit’s exterior is engineered to withstand extreme conditions, from harsh sunlight to icy weather.
Installation Specifics – Crafting the Perfect Setup
For this installation, we carefully selected a rooftop location to optimize airflow and reduce noise impact. By mounting the exterior unit securely, we ensured its stability and optimal performance, even in high winds or snowy conditions. Wooden beams were used as a base for added support, preventing vibrations from disturbing the building’s structure. This installation’s configuration not only prioritizes efficiency but also makes future maintenance easy, a feature that is particularly appreciated by our customers in Montréal-Nord.
Why the SHARP ZU1 Is a Smart Investment
With its 10-year warranty covering compressor, parts, and labor, the SHARP ZU1 promises reliability and peace of mind for years to come. It’s a system designed for the long haul, offering energy savings and robust performance even in the most frigid winter months. Plus, with the LogisVert Grant incentive, customers can recoup a portion of their investment, making this installation not only a comfort upgrade but a financially sound choice as well.
Technical Specifications
- Model: SHARP ZU1
- Cooling Capacity: 24,000 BTU
- Heating Capacity: Effective to -27°C
- Interior Dimensions (L x D x H): 41.42 x 9.80 x 12.44 inches
- Exterior Dimensions (L x D x H): 33.47 x 13 x 27.94 inches
- Voltage: 220V
- Sound Pressure Level: 53 dB(A) exterior, 25-49 dB(A) interior
- AHRI Certified: Yes, with code 213246054
- Warranty: 10 years on compressor, parts, and labor
Eco-Friendly Performance with R-32 Refrigerant
As a responsible HVAC provider, we’re proud to install systems that are environmentally friendly. The SHARP ZU1 uses R-32 refrigerant, which has a lower global warming potential (GWP) compared to other common refrigerants like R-410A. This helps homeowners reduce their carbon footprint while enjoying a high-performance system that meets today’s energy standards.
Unparalleled Comfort with the Coanda Airflow Effect
One of the unique selling points of the SHARP ZU1 is its Coanda Airflow technology, which directs airflow along the ceiling, allowing even distribution of warm or cool air without direct exposure. This enhances comfort by eliminating cold drafts and hot spots, providing a more consistent indoor climate.
Customer Satisfaction and Aftercare
At AirGreen, customer satisfaction is our top priority. After completing the installation, we conducted a thorough system check, ensuring that every component was functioning perfectly. We also provided the homeowner with detailed instructions on using the WiFi controls, setting energy-saving modes, and scheduling maintenance checks. Our goal is to make HVAC ownership as easy and worry-free as possible.
Why Choose AirGreen for Your HVAC Needs?
With years of experience serving Montreal, Laval, Longueuil, North Shore, and South Shore, AirGreen is a trusted partner for residential and commercial HVAC solutions. Our expert technicians are committed to delivering high-quality installations, backed by our dedication to customer satisfaction. When you choose AirGreen, you’re not only getting top-notch equipment but also a team that cares about your comfort and peace of mind.
The unit on this job, in figures
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).