Installation of a Sharp ZU1 series wall-mounted heat pump on a flat roof in Rosemont–La Petite-Patrie
AirGreen installed three Sharp ZU1 heat pumps on a flat roof in Rosemont–La Petite-Patrie. A high-performance, safe, and durable winter HVAC system from AirGreen Montréal.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A triple installation in the heart of Montreal's winter
At AirGreen , we recently completed an installation of three Sharp ZU1 series outdoor units on the flat roof of a residential building in the Rosemont–La Petite-Patrie neighborhood. This project perfectly illustrates our expertise in implementing high-performance HVAC systems in Montreal's dense urban environments.
Despite still very present winter conditions – partial snow, meltwater and fluctuating temperatures – our team carried out a safe, stable and energy-optimized installation .
Equipment selection: the Sharp ZU1 series, a standard for winter comfort
The Sharp ZU1 is a high-performance wall-mounted heat pump , designed to withstand the harsh Quebec climate. Capable of providing efficient heating down to -25°C , it combines inverter technology and R-32 refrigerant, ensuring superior energy efficiency and quiet operation.
For this multi-unit building, three independent systems were chosen:
-
Capacities from 12,000 to 18,000 BTU depending on the indoor units;
-
Four-season heating and cooling mode ;
-
Compatibility with provincial subsidies (high-performance heat pump programs).
A flat roof, a challenge mastered
Installing heat pumps on a flat roof requires meticulous planning:
-
Raised galvanized steel supports to avoid direct contact with the roofing membrane;
-
Treated wooden sleepers placed on anti-vibration feet to distribute the load and protect the waterproofing;
-
Precise routing of refrigerant lines and electrical wiring , carefully sheathed to resist frost and UV rays;
-
Condensate management by gravity flow, avoiding any accumulation of water under the units.
This type of installation offers several advantages: easier access for maintenance , better air circulation around the units and increased sound insulation for the building's occupants.
Precision work by AirGreen
Our RBQ and CCQ certified technicians coordinated all the steps:
-
Structural assessment of the roof;
-
Installation of the power supply on a dedicated circuit breaker;
-
Checking the flow slopes for condensates;
-
Full performance testing before commissioning.
Every Sharp unit has been tested to ensure optimal operation in heating mode, even at low temperatures. The result: a reliable, balanced and durable system, ready to provide consistent comfort all year round.
A sustainable and energy-efficient investment
By choosing the Sharp ZU1 , owners benefit from excellent value for money , while reducing their carbon footprint. Thanks to frequency inversion technology , energy consumption is adjusted according to actual demand, which results in:
-
Up to 40% energy savings compared to traditional electric heating;
-
Extended equipment life ;
-
A significant reduction in outside noise .
Why choose AirGreen for your flat roof projects?
Montreal roofs present unique challenges—snow, freeze-thaw cycles, and access constraints—but also great opportunities. At AirGreen, we master installation protocols that comply with City of Montreal standards and manufacturer requirements.
Our interventions guarantee:
-
Full compliance with RBQ and CSA standards ;
-
Complete protection of the roof membrane ;
-
An aesthetic and watertight routing of the conduits ;
-
Post-installation monitoring including seasonal maintenance.
Technical summary of the installation
| Element | Technical details |
|---|---|
| Place | Rosemont–La Petite-Patrie, Montreal |
| Kind | Sharp ZU1 Series Wall-Mounted Heat Pump |
| Assembly | Flat roof – raised metal supports with wooden crosspieces |
| Drainage | Gravity-fed, frost-protected |
| Climate | Installation in winter conditions |
| Special features | Three independent units, simultaneous installation, dense urban configuration |
Your project, our expertise
Whether you own a duplex, a rental property, or a commercial building, AirGreen offers complete HVAC solutions tailored to your space and budget.
Our teams operate in Montreal, Laval, Longueuil, on the South Shore and the North Shore , with the same rigor and the same commitment to quality.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).