Project

Installation of a SHARP ZU1 18,000 BTU Wall-Mounted Heat Pump in Saint-Jean-sur-Richelieu

AirGreen installed a SHARP ZU1 18,000 BTU wall-mounted heat pump in Saint-Jean-sur-Richelieu. A quiet, energy-efficient, and effective solution—perfect for a residential kitchen.

By AirGreen Climatisation & Chauffage Admin4 min read
Installation of a SHARP ZU1 18,000 BTU Wall-Mounted Heat Pump in Saint-Jean-sur-Richelieu
Installation of a SHARP ZU1 18,000 BTU Wall-Mounted Heat Pump in Saint-Jean-sur-Richelieu
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

A high-performance and stylish solution to optimize comfort in a residential kitchen

At AirGreen, our mission is clear: to provide customized HVAC installations that are durable and adapted to Québec’s climate. Recently, our team had the pleasure of completing a new installation of a SHARP ZU1 18,000 BTU wall-mounted heat pump in a residence located in Saint-Jean-sur-Richelieu, in the Montérégie region. This project, carried out in a residential kitchen, perfectly illustrates our attention to detail, professionalism, and ability to seamlessly integrate heating and cooling solutions into functional living spaces.


Why choose the SHARP ZU1 Series?

The SHARP ZU1 heat pump, operating with the eco-friendly R-32 refrigerant, is an excellent choice for Québec’s climate. This specific 18,000 BTU model provides stable performance even in temperatures as low as -27°C, making it an ideal solution for the harsh winters of the South Shore.

Key technical features:

  • Heating capacity: up to 21,600 BTU/h

  • Cooling capacity: up to 18,000 BTU/h

  • Operating temperature range: from -27°C to 46°C

  • SEER: 24, ensuring optimal energy efficiency in summer

  • HSPF: up to 13, guaranteeing high performance in winter

  • Integrated Plasmacluster Technology for active air purification

The Plasmacluster technology is exclusive to SHARP. It emits positive and negative ions capable of neutralizing mold, viruses, bacteria, and airborne allergens, significantly improving indoor air quality.


Context and specific features of the installation in Saint-Jean-sur-Richelieu

The project involved installing the indoor unit directly in the client’s kitchen, a strategic and often complex area when it comes to airflow, heat, and humidity.

Technical challenges encountered:

  • Limited space between the top cabinets and the ceiling crown molding

  • Need for aesthetic discretion and harmonious integration with the existing decor

  • Limited wall access for unit placement and piping to the outdoor unit

  • Preservation of the workspace (countertop and sink area)

Our approach:

Our certified technicians took the time to thoroughly analyze the layout of the room. The SHARP wall unit was carefully installed just a few centimeters from the ceiling, perfectly aligned with the cabinets, ensuring optimal airflow circulation without interfering with the kitchen’s functional elements.

The installation was completed in a single day, including:

  • Discreet drilling for refrigerant lines and wiring

  • Setup of the condensate drain hose

  • Electrical hookup with a dedicated 25 A breaker

  • Full system pressure and functionality check

  • Initial settings configuration and user demonstration


Immediate benefits for the client

From the very first moments of operation, the SHARP ZU1 heat pump provided even air distribution throughout the kitchen thanks to its manual horizontal and automatic vertical airflow direction. The large blower flap allows air to reach up to 50 feet, ensuring quick and consistent thermal comfort.

What the client particularly appreciated:

  • The quiet operation of the unit (only 28 to 49 dB)

  • The sleek, compact design of the indoor unit (41” wide)

  • The simple control via an intuitive remote

  • The improved air quality thanks to Plasmacluster technology

  • The reduced energy consumption, notably due to the high-performance inverter


An installation eligible for government grants

Thanks to its exceptional energy efficiency, the SHARP ZU1 18,000 BTU heat pump is potentially eligible for LogisVert grants from Hydro-Québec, which can reach up to $1,704. Our team informed the client of all the necessary steps to apply to the program and obtain this financial support.


Why choose AirGreen for your heat pump project?

With every project, we deliver:

  • In-depth technical HVAC expertise

  • Comprehensive support before, during, and after installation

  • Clean, safe, and aesthetic installations

  • Personalized advice tailored to your space and needs

  • A friendly and accessible after-sales service

We serve the entire South Shore, as well as Greater Montréal, including Montréal, Laval, Longueuil, Brossard, Saint-Bruno, and Saint-Jean-sur-Richelieu, offering top-tier, durable, and eco-friendly HVAC solutions.


Key takeaways

The SHARP ZU1 18,000 BTU wall-mounted heat pump installed by AirGreen in Saint-Jean-sur-Richelieu is far more than just a heating and cooling unit. It’s a complete comfort and air quality system, perfectly suited to Québec conditions, combining performance, energy efficiency, and active air purification.


Professional advice from AirGreen

  • Choose a power output adapted to your room to avoid excess consumption or reduced effectiveness.

  • Think about the strategic placement of the indoor unit to ensure even air distribution.

  • Schedule annual HVAC maintenance to preserve energy efficiency and air quality.

  • Look into available grants before you invest—they can significantly reduce your total installation cost.


Thinking about installing a SHARP wall-mounted heat pump?

Contact us today for a free quote, a personalized thermal evaluation, and guidance on available grants. At AirGreen, your comfort is our priority.

In figures
The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
The unit

What the unit delivers when it is cold

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment