Installation of a Sharp ZU1 Mini Split in Boisbriand
Discover how AirGreen installed a powerful Sharp ZU1 Mini Split in Boisbriand, offering advanced air purification, energy efficiency, and exceptional performance in extreme winter temperatures.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Exceptional Comfort for All Seasons: The Sharp ZU1 Mini Split Installation
At AirGreen, we take pride in offering high-quality HVAC solutions to our clients across Montreal, Laval, Longueuil, North Shore, and South Shore. Our recent project in Boisbriand exemplifies this dedication, as we successfully installed a Sharp ZU1 Mini Split system to provide our customer with year-round comfort, energy efficiency, and advanced air purification.
This installation required precision and attention to detail, and it’s not just about placing a machine; it’s about crafting an environment where the family can enjoy a comfortable indoor climate regardless of the weather outside. Let's dive into the details of this exciting project.
Why the Sharp ZU1 is the Ideal Choice
The Sharp ZU1 Mini Split is renowned for its exceptional performance and energy efficiency. With a cooling capacity of 18,000 BTU and heating capabilities down to -27°C, it’s engineered to handle the most extreme Quebec winters. This model is also Energy Star® certified, ensuring that it meets the highest standards for energy efficiency.
One of the standout features of this system is its use of the R-32 refrigerant, which is known for being more environmentally friendly than previous refrigerants, reducing the system's carbon footprint and ensuring compliance with future government energy regulations. As part of our commitment to sustainability, we are proud to offer products like the ZU1, which align with modern environmental standards.
The Installation Process: A Smooth, Seamless Experience
At AirGreen, we prioritize making the installation process as smooth and efficient as possible. For this Boisbriand home, our team conducted a detailed assessment to ensure that the system would be perfectly suited to the space. We installed both the indoor unit and the outdoor compressor in strategic locations, ensuring optimal airflow and performance.
-
Interior Unit: Measuring 41.42 x 9.80 x 12.44, the indoor unit was installed in a living area where it would have maximum impact. Its compact design ensures it doesn’t intrude on the aesthetics of the room while delivering whisper-quiet operation at only 25 dB(A), ensuring that the family can enjoy their comfort without any unnecessary noise.
-
Outdoor Unit: The exterior unit, with dimensions of 33.47 x 13 x 27.94, was placed on a solid foundation outside the home. Despite its robust performance, this unit operates at just 52 dB(A), which is about as loud as a conversation, making it one of the quieter options available on the market.
Key Features of the Sharp ZU1 Mini Split
High-Efficiency Performance
The Sharp ZU1 offers an impressive 24.0 SEER rating, making it one of the most efficient units available. This means lower electricity bills for the homeowner and a more environmentally friendly way to heat and cool their home. In a province like Quebec, where extreme weather can lead to sky-high heating costs, this level of efficiency is a game-changer.
Plasmacluster Air Purification
One of the Sharp ZU1's most unique features is its Plasmacluster technology, which purifies the air by eliminating airborne bacteria, mold, and viruses. For families concerned about air quality, this feature ensures that the indoor environment is not just comfortable but also healthy.
- Removes allergens like pollen and dust.
- Neutralizes viruses and bacteria.
- Reduces odors from pets or tobacco, ensuring the air inside the home remains fresh and clean.
Coanda Airflow for Even Comfort
We know that Quebec homes often have multiple rooms and floors, and maintaining even temperatures across spaces can be a challenge. The Coanda airflow control ensures that hot or cold air is directed throughout the home evenly, reaching every corner and ensuring a consistent, comfortable temperature throughout.
Quiet and Discreet Operation
This Sharp ZU1 Mini Split is designed to be quiet and unobtrusive. The indoor unit operates at a low 25 dB(A), making it quieter than a whisper, while the outdoor compressor is similarly discreet at 52 dB(A). This makes it an ideal choice for homeowners who prioritize a peaceful indoor environment.
Government Grants and Rebates
One of the highlights of this installation is that the Sharp ZU1 Mini Split is eligible for the LogisVert Grant by Hydro-Québec, offering up to $2,640 in rebates. For homeowners looking to upgrade their HVAC system while reducing costs, this grant makes the Sharp ZU1 an even more appealing option.
Why Choose AirGreen?
At AirGreen, we believe in delivering more than just a product—we offer an experience. Our team is dedicated to making every step of the process, from choosing the right unit to final installation, as easy and efficient as possible for our customers.
- Expert technicians: Our team consists of certified professionals who have extensive experience installing a wide range of HVAC systems.
- Tailored solutions: We always assess the specific needs of each customer to ensure the installed system is the perfect match for their home.
- Aftercare support: We don't just leave after the installation is complete; we offer ongoing maintenance services to ensure your system continues to operate at peak performance.
Conclusion: Bringing Comfort to Boisbriand with Sharp ZU1
This installation in Boisbriand is just one example of how AirGreen brings advanced HVAC technology to homes across the region. The Sharp ZU1 Mini Split offers the perfect balance of energy efficiency, air purification, and powerful heating and cooling capabilities. With its 24.0 SEER efficiency, Plasmacluster air purification, and Coanda airflow control, it’s no wonder that this model is quickly becoming a top choice for homeowners looking to upgrade their comfort systems.
If you're considering upgrading your HVAC system, now is the perfect time to explore the Sharp ZU1 Mini Split. With government rebates available and AirGreen's expertise, we make it easier than ever to enhance your home's comfort and energy efficiency.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).