Installation of a Sharp ZU1 wall-mounted heat pump in Saint-Léonard
Installation of a Sharp ZU1 wall-mounted heat pump in Saint-Léonard by AirGreen: performance, energy efficiency and optimal comfort to face the winters of Montreal, Laval, the North Shore and the South Shore.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
An exemplary winter installation by AirGreen: performance, reliability and expertise
On this typical brick house in Saint-Léonard , our teams recently installed a Sharp ZU1 wall-mounted heat pump , a model known for its R-32 Inverter technology and exceptional performance even below -25°C . This project perfectly illustrates our expertise in residential HVAC installation in Greater Montreal.
A strategic replacement to maximize energy efficiency
The client had an old air conditioning unit, which was now obsolete and inefficient for winter heating. We therefore proposed the Sharp ZU1 , a highly efficient, Energy Star certified model, offering optimal comfort all year round. This replacement was part of an effort to reduce energy costs and access provincial subsidies available for high-efficiency heat pumps.
The technical features of this installation
This installation presented several challenges:
-
Brick wall requiring suitable anchors for wall brackets.
-
Installation height calculated to avoid any contact with snow and ensure optimal drainage.
-
Piping and wiring carefully capped and secured for discreet aesthetics and increased durability.
-
Gravity drainage to the outside, preventing pipes from freezing in winter.
The heat pump was mounted on galvanized wall brackets , providing excellent stability and protection against moisture and vibration. The insulated and covered refrigerant passage connects the outdoor unit to the indoor head with minimal drilling, ensuring wall integrity and system efficiency.
Optimal performance even in extreme conditions
The Sharp ZU1 is distinguished by its variable speed compressor , allowing for smooth and quiet operation. This model offers stable performance down to -25 °C , ensuring reliable heating even during the typical Saint-Léonard cold. The unit operates on R-32 refrigerant , which is environmentally friendly and more efficient than R-410A.
Thanks to this technology, the customer now benefits from:
-
Constant and economical heating ;
-
From rapid cooling during summer;
-
A significant reduction in energy costs ;
-
Quiet in operation , ideal for residential areas.
Winter, a factor we always anticipate
The installation took place in the middle of winter, in heavy snow conditions. We adjusted the height and orientation of the outdoor unit to ensure good air circulation and prevent ice buildup. This kind of detail makes the difference between a simple installation and a lasting engineering project .
Why choose AirGreen for your HVAC installations in Montreal and surrounding areas?
At AirGreen , we have mastered the art of adapting each installation to the climatic realities of Quebec . Each project is preceded by a personalized analysis : building structure, orientation, insulation and thermal needs. Our certified technicians ensure precise work, compliant with CSA and RBQ standards , while guaranteeing a clean and durable result .
We operate throughout Greater Montreal , including Montreal, Laval, Longueuil, the North Shore and the South Shore , with the same attention to detail and performance.
A clean installation, an impeccable result
As seen in the photo, the new Sharp ZU1 sits securely on the wall, perfectly aligned, with ample space around it to ensure optimal airflow. Nearby, the old compressor, now decommissioned, highlights the difference between an aging system and the precision of modern equipment.
Grants and financial benefits
The Sharp ZU1 is eligible for several provincial grant programs, including the Chauffez Vert program and certain municipal grants for converting to high-efficiency systems. Our advisors support each client to maximize these financial returns , significantly reducing the overall cost of the project.
Customer satisfaction at the heart of every installation
The owner, impressed by the speed and precision of our team, now benefits from consistent thermal comfort and a significant reduction in his energy bill . At AirGreen, it is this type of concrete result that guides each of our interventions.
In short , this Sharp ZU1 wall-mounted heat pump installation in Saint-Léonard demonstrates our commitment to providing efficient, aesthetically pleasing, and durable HVAC solutions . Every detail—from mounting to system calibration—reflects our commitment to quality and our passion for a job well done.
The unit on this job, in figures
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).