The job on one screen

The unit’s data sheet
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The article, chapter by chapter
Experience the Ultimate Comfort with our Latest Heat Pump Installation in Montréal
At AirGreen, we are passionate about bringing optimal heating and cooling solutions to residents and businesses across Montréal, Laval, Longueuil, and the surrounding areas. Recently, our skilled technicians completed a high-performance installation of an 18,000 BTU SHARP ZU1 Mini Split Heat Pump in the vibrant Ville-Marie borough of Montréal. This installation showcases not only the exceptional capabilities of the SHARP ZU1 model but also our commitment to precision and customer satisfaction.
Project Overview: The SHARP ZU1 Mini Split Heat Pump
In this installation, we utilized the powerful SHARP ZU1 mini split system, renowned for its high efficiency, robust cooling, and reliable heating capabilities. This model operates at 18,000 BTU, perfectly designed to handle the unique climate challenges of Québec, where temperatures can plummet as low as -27°C. With features like Plasmacluster Ion Technology for air purification and WiFi connectivity, the SHARP ZU1 is a powerhouse in both performance and convenience.
- Cooling Capacity: 18,000 BTU
- Heating Capacity: Effectively operates down to -27°C
- Interior Serial Number: AY-XP18ZU1
- Exterior Serial Number: AE-X18ZU1
- Dimensions (Interior): 41.42 x 9.80 x 12.44 inches
- Dimensions (Exterior): 33.47 x 13 x 27.94 inches
- Voltage: 220V
- Sound Pressure Level (Exterior): 52.0 dB(A)
- Sound Pressure Level (Interior): 25 - 49 dB(A)
- Refrigerant: R-32

Why Choose the SHARP ZU1 for Heating and Cooling?
The SHARP ZU1 is an ideal choice for Ville-Marie's demanding conditions. This model not only provides superior energy efficiency with a SEER of 24.0, but it’s also Energy Star® certified, ensuring energy savings and a reduced environmental footprint. With an impressive noise reduction design (quietly operating at 25-49 dB indoors), this unit allows our customers to enjoy optimal comfort without the intrusion of unwanted noise.
Additionally, this unit qualifies for the highest LogisVert Grant by Hydro-Québec at $2,640 in the 18,000 BTU category, making it a fantastic investment for those looking to save on energy costs while improving their indoor environment.
Air Purification Benefits with SHARP’s Plasmacluster Technology
One of the unique advantages of the SHARP ZU1 is its Plasmacluster Ion Technology. This proprietary technology is designed to release ions that neutralize airborne particles, effectively purifying the air by targeting viruses, bacteria, mold, and allergens. For customers, this means cleaner, healthier air within their living spaces, which is especially beneficial in urban environments like Montréal, where indoor air quality can often be compromised.
Key Benefits of Plasmacluster Ion Technology:
- Reduces airborne mold and suppresses virus activity.
- Neutralizes allergens, including dust mites.
- Eliminates lingering odors, such as smoke or pet smells.
- Improves overall air quality by reducing static electricity, allowing for a cleaner environment.
Installation Details: Precision and Care in Every Step
For this project, our technicians installed the SHARP ZU1 unit in a way that maximized efficiency and ensured optimal operation. The exterior unit, mounted on a custom-designed support system, is strategically placed to provide easy access for maintenance while remaining unobtrusive to the surrounding area. Given the dimensions and weight of the unit, precision was essential. Our team ensured the 1/4 - 3/8 piping was installed with care, optimizing airflow and enhancing the overall longevity of the system.
Our meticulous installation process also involved testing the unit to confirm its cooling and heating capacity at extreme temperatures. Ville-Marie’s parking structures can present challenges with ventilation, but thanks to the Coanda air control feature, this heat pump disperses airflow efficiently without creating direct drafts, providing a balanced climate within the space.
An Investment in Year-Round Comfort and Energy Savings
The SHARP ZU1 Mini Split Heat Pump is more than just an HVAC system; it’s an investment in comfort, efficiency, and cleaner air. Its ability to operate seamlessly down to -27°C provides our client with the assurance of warmth even on the coldest days in Montréal. Plus, with an included 10-year warranty on the compressor, parts, and labor, the SHARP ZU1 offers long-term reliability and peace of mind.
In addition to offering efficient heating and cooling, this unit is also equipped with smart features that enhance user convenience. Its integrated WiFi functionality allows users to monitor and control their climate settings remotely, ensuring a comfortable environment upon arrival, whether at home or in a commercial space. This feature not only boosts convenience but also allows for energy-saving adjustments on the go.
Why AirGreen? Our Commitment to Excellence in HVAC
At AirGreen, we take pride in delivering top-tier HVAC solutions that are customized to meet the unique needs of our clients. Each installation is carried out with precision, from the initial assessment to the final touches, ensuring a flawless setup every time. For residents and businesses across Montréal, Laval, Longueuil, North Shore, and South Shore, we offer not just products but peace of mind through dependable service and innovative HVAC solutions.
Our Key Values:
- Professionalism and Expertise: Our team is composed of highly trained technicians who are passionate about delivering the best possible service.
- Customer Satisfaction: We prioritize your comfort and satisfaction, aiming to exceed your expectations on every project.
- Eco-Friendly Solutions: We work with energy-efficient systems that not only save costs but also reduce environmental impact.
Why Choose a Ductless System? Advantages of Mini Split Heat Pumps
Opting for a ductless mini split system like the SHARP ZU1 provides numerous benefits over traditional HVAC systems. Here are a few highlights:
- Flexible Installation: Mini splits are versatile and can be installed in various spaces without extensive ductwork, which is ideal for renovations or challenging layouts.
- Energy Efficiency: With targeted heating and cooling, mini splits offer better efficiency by focusing only on the areas that need temperature control.
- Enhanced Air Quality: The Plasmacluster Ion Technology actively improves indoor air quality, adding value beyond mere temperature control.
- Quiet Operation: Mini splits are designed to be quiet, making them ideal for environments where noise reduction is a priority.
Contact AirGreen for Your HVAC Needs
If you're in the market for a high-quality HVAC solution in Montréal or the surrounding regions, look no further than AirGreen. We’re here to guide you every step of the way, from selecting the right model to professional installation and maintenance services. With the SHARP ZU1, you’re not only investing in a heat pump but in a future of comfort, clean air, and energy savings.
Experience the difference with AirGreen, where innovation meets reliability.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).