Installation of a Sharp ZU1 Mini Split Heat Pump in Town of Mount Royal
Discover the comfort and efficiency of the Sharp ZU1 heat pump in TMR. Enjoy superior heating to -27°C, eco-friendly R-32 refrigerant, and a $2,172 rebate!
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The unit’s data sheet
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The article, chapter by chapter
Efficient Heating and Cooling for Quebec’s Extreme Weather
In the scenic neighborhood of Town of Mount Royal (TMR), our team at AirGreen recently completed an installation that exemplifies our commitment to quality and reliability. The project involved setting up a 15,000 BTU Sharp ZU1 wall-mounted mini split heat pump, a top choice for homeowners across Montreal, Laval, Longueuil, the North Shore, and the South Shore. This modern, energy-efficient system is not only ideal for Quebec’s cold winters but also excels at providing cooling during the sweltering summer months.
Bringing Comfort to Every Corner of the Home
Our client in TMR needed a dependable heating solution capable of withstanding Quebec's harsh winter temperatures, which often drop well below freezing. The Sharp ZU1, with its heating capacity extending down to -27°C, easily delivers consistent warmth even under the most severe conditions. Additionally, its 24.0 SEER rating ensures optimal energy efficiency, helping to keep heating costs in check.
The Sharp ZU1 represents a new generation of heat pumps, using the eco-friendly R-32 refrigerant, known for its lower environmental impact and superior efficiency. This installation not only enhances immediate comfort but also aligns with Hydro-Québec’s sustainability goals, as it qualifies for the substantial $2,172 LogisVert Grant—the highest rebate available for a 15,000 BTU unit in the province.
Smooth and Clean Installation Process
Installing the Sharp ZU1 mini split heat pump required meticulous planning and execution. The outdoor unit was securely mounted on a durable bracket, positioned to ensure optimal airflow and minimize noise for the homeowner. The indoor unit was strategically placed to maximize airflow distribution, ensuring even heating and cooling throughout the living space. We used high-quality insulated copper pipes for efficient refrigerant flow and installed premium electrical wiring to ensure the system’s longevity.
While on-site, we took the opportunity to thoroughly clean the client’s old system. As the photos reveal, the coils of the existing unit were heavily clogged with dust and debris, impairing its efficiency. After a professional cleaning, the old system was restored to near-optimal performance. The customer was delighted with this added effort, especially since the improvement in air quality was immediately noticeable.
The Advanced Technology of the Sharp ZU1
Plasmacluster Air Purification – A Healthier Home Environment
One of the standout features of the Sharp ZU1 heat pump is its Plasmacluster air purification technology. This advanced system releases positive and negative ions into the air, neutralizing airborne contaminants such as viruses, allergens, and odors. It’s an ideal solution for families who prioritize indoor air quality, providing peace of mind that every breath taken indoors is fresh and clean.
Coanda Airflow Control – Achieving Perfect Comfort
The Sharp ZU1 also incorporates Coanda airflow control, a sophisticated feature that mimics natural air movement to evenly distribute air throughout the room. By guiding warm air downward in the winter and cool air upward in the summer, this mechanism helps maintain a consistent temperature without uncomfortable drafts. Whether you’re near the window or in a distant corner, you can count on uniform comfort in every part of your home.
Hot Gas Pipe System – Winter-Ready Performance
The ability of the Sharp ZU1 to operate efficiently down to -27°C is made possible by its patented Hot Gas Pipe system. This innovative technology circulates hot gas through the piping to prevent the outdoor compressor from freezing, ensuring reliable operation even during the coldest winter days. For homeowners in Quebec, where extreme weather is the norm, this feature is invaluable.
Why Choose AirGreen for Your Heat Pump Installation?
At AirGreen, we are committed to delivering not just quality products but also an unmatched customer experience. Our expertise in HVAC installation and maintenance ensures that every project we undertake meets the highest standards of excellence. The Sharp ZU1 installation in TMR is a prime example of how we go above and beyond to meet our clients’ needs.
A Focus on Eco-Friendly Solutions
As part of our commitment to sustainability, we ensure that all our installations prioritize energy-efficient and eco-friendly solutions. The Sharp ZU1’s use of R-32 refrigerant marks a significant step toward reducing greenhouse gas emissions, contributing to a cleaner environment while also helping homeowners save on energy costs.
Seamless Maintenance Services
We understand that HVAC systems require regular maintenance to function at their best. Our comprehensive services include not only installation but also periodic cleaning and servicing of existing equipment. During this installation, our technicians took the time to clean and wash the old system as a complimentary service, significantly enhancing its efficiency and extending its lifespan. The client appreciated this additional effort, as it improved the indoor air quality and prolonged the life of their current equipment.
Benefits of Upgrading to a Sharp ZU1 Heat Pump
- Energy Efficiency: The Sharp ZU1’s 24.0 SEER rating means reduced energy consumption, leading to substantial savings on electricity bills.
- Cold Climate Performance: With a heating capacity that extends to -27°C, this heat pump ensures your home stays warm even under extreme conditions.
- Air Quality Improvement: The Plasmacluster technology helps eliminate airborne pollutants, providing a cleaner, healthier living environment.
- Environmental Responsibility: By using R-32 refrigerant, the Sharp ZU1 has a lower global warming potential, aligning with modern sustainability goals.
- Quiet Operation: The 49.0 dB(A) exterior sound pressure level ensures a peaceful atmosphere, free from disruptive noise.
A Grant You Can’t Afford to Miss
One of the most attractive aspects of this installation is its eligibility for the $2,172 LogisVert Grant by Hydro-Québec. This generous rebate is the highest available for any 15,000 BTU mini split heat pump in the province, making it an economically smart choice for homeowners looking to upgrade their HVAC systems.
AirGreen – Your Trusted Partner in HVAC Solutions
We believe in building long-term relationships with our clients, which is why we go beyond simple installations. Our team of certified technicians not only installs top-quality products like the Sharp ZU1 but also ensures that they are well-maintained and optimized for peak performance. The satisfaction of our TMR client is just one example of the kind of service you can expect when you choose AirGreen.
Experience Unmatched Comfort and Efficiency with the Sharp ZU1
In conclusion, the installation of the Sharp ZU1 mini split heat pump in Town of Mount Royal is more than just a home upgrade; it’s a step toward a more comfortable, efficient, and environmentally friendly lifestyle. With cutting-edge technologies like Plasmacluster air purification, Coanda airflow control, and the Hot Gas Pipe system, the Sharp ZU1 offers a perfect balance of performance and affordability. And with the added benefit of the LogisVert Grant, there’s never been a better time to invest in a high-quality heat pump for your home.
For anyone in the Greater Montreal area, including Laval, Longueuil, the North Shore, and the South Shore, we invite you to contact AirGreen for your next HVAC project. Experience the benefits of professional installation, exceptional service, and state-of-the-art technology. Your comfort is our priority.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).