In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
At AirGreen, we are proud to offer superior HVAC services throughout Montreal, Laval, Longueuil, the North Shore, and the South Shore. Recently, we completed the installation of a Sharp ZU1 24,000 BTU wall-mounted heat pump in Villeray–Saint-Michel, setting a new standard in comfort, efficiency, and air quality. This project illustrates our commitment to providing the best heating and cooling solutions tailored to the unique needs of homeowners in Quebec.
A smart choice for extreme climates
The Sharp ZU1 is designed to excel in extreme weather conditions, making it an ideal choice for Quebec’s harsh winters and hot summers. With a heating capacity that operates down to -27°C, this wall-mounted heat pump is specially designed to keep you warm even on the coldest days. The 24,000 BTU cooling capacity provides robust air conditioning to maintain a comfortable indoor environment during summer heat.
The environmental advantage: R-32 refrigerant
This installation features the R-32 refrigerant, a more sustainable and efficient alternative to traditional options. R-32 significantly reduces the heat pump’s environmental footprint by lowering greenhouse gas emissions and improving energy efficiency. Its use complies with upcoming government energy efficiency standards and reflects our commitment to offering environmentally friendly HVAC solutions.
Plasmacluster technology: Improve your home’s air quality
The Sharp ZU1 heat pump does more than control temperature; it also enhances air quality. Using Plasmacluster technology, the unit effectively eliminates viruses, bacteria, allergens, and mold suspended in the air while neutralizing unpleasant odors. This unique technology replicates natural air purification processes, ensuring an indoor environment that is not only comfortable but also healthier. Here’s how Plasmacluster technology works to improve air quality:
- Ion diffusion: The system releases positive and negative ions similar to those found in nature, wrapped in water molecules to extend their lifespan.
- Contaminant neutralization: The ions attack contaminants, including viruses and mold, by breaking down their molecular structures.
- Return to water molecules: Finally, the ions combine with other elements in the air to revert to water vapor, ensuring no harmful residue remains.

Optimal airflow control with Coanda effect technology
The Sharp ZU1 uses Coanda effect technology, which optimizes airflow to ensure even temperature distribution throughout the home. Instead of blowing air directly on occupants, the unit redirects airflow along walls and ceilings, providing a draft-free experience. This feature is especially beneficial in homes with irregular layouts or multiple floors, as it promotes consistent temperatures in all rooms.
Comfort guaranteed all year round
Quebec winters are no obstacle for the Sharp ZU1 heat pump. The system uses hot gas pipe technology to prevent the outdoor compressor from freezing, ensuring continuous operation even in extreme cold conditions. The heat pump’s defrost function is designed to reduce energy consumption and minimize indoor temperature fluctuations during defrost cycles, allowing uninterrupted comfort during cold spells.
A long-term investment in quality
Every component of the Sharp ZU1 is built to last. The unit features anti-corrosion coatings, multiple drainage holes to prevent freezing, and a durable compressor capable of delivering consistent performance. For added peace of mind, this installation is covered by a comprehensive 10-year warranty on the compressor, parts, and labor.
Modern features for optimal comfort
This Sharp ZU1 installation is equipped with WiFi connectivity, allowing homeowners to control the system remotely via a smartphone app. The app provides real-time information on temperature, humidity, and energy consumption, enabling smarter energy use and cost savings. It also supports auto-changeover mode, which automatically switches between heating and cooling as needed.
Eligible for the largest LogisVert credit
Homeowners can benefit from the $2,688 Hydro-Québec LogisVert credit, the highest offered for a 24,000 BTU wall-mounted heat pump. This credit not only reduces the initial cost but also highlights the energy-efficient and environmentally friendly design of the Sharp ZU1. Taking advantage of this credit is a smart decision to reduce your carbon footprint and energy bills.
Why choose AirGreen for your HVAC needs?
At AirGreen, we bring extensive experience and unmatched expertise to every HVAC project. Our installation in Villeray–Saint-Michel was carefully planned to meet the unique needs of the homeowner, ensuring the Sharp ZU1 heat pump was perfectly sized and positioned for optimal performance. We also ensured that the unit’s piping and electrical connections met the highest standards, preserving the system’s efficiency and longevity.
Choosing AirGreen means partnering with a team that prioritizes customer satisfaction, energy efficiency, and environmental responsibility. Our team will support you every step of the way, from selecting the right unit to applying for available credits, providing a smooth and rewarding experience.
Technical specifications at a glance
- Cooling capacity: 24,000 BTU
- Heating capacity: Operates down to -27°C
- Indoor dimensions: 41.42 x 9.80 x 12.44 inches
- Outdoor dimensions: 33.47 x 13 x 27.94 inches
- Indoor sound pressure level: 25 / 49 dB(A)
- Outdoor sound pressure level: 53.0 dB(A)
- Energy Star® certification: Yes
- Refrigerant: R-32
- Efficiency: 22.0 SEER
- Warranty: 10 years (Compressor, Parts, Labor)
A perfect blend of comfort, efficiency, and innovation
The installation of the Sharp ZU1 heat pump in Villeray–Saint-Michel represents the future of HVAC solutions. Combining advanced Plasmacluster technology, Coanda airflow control, and a durable R-32 refrigerant, the Sharp ZU1 sets a new standard in comfort and efficiency. With AirGreen, you can be confident that your HVAC system will operate optimally while minimizing its environmental impact.
For homeowners in Montreal, Laval, Longueuil, and surrounding areas, choosing a Sharp ZU1 heat pump installed by AirGreen means opting for quality, reliability, and energy efficiency. Contact us today to learn more about how we can transform your indoor climate.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).