Project

Installation of a Zephyr wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension

Zephyr wall-mounted heat pump installed in Villeray: discreet interior head, gravity drain, neat exterior capping. AirGreen, HVAC experts in Montreal, Laval, Longueuil, North Shore and South Shore . Comfort, silence and efficiency.

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of a Zephyr wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension
Installation of a Zephyr wall-mounted heat pump in Villeray–Saint-Michel–Parc-Extension
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

Careful integration for a Montreal condo: comfort, silence and aesthetics every day

At AirGreen , we have just installed a Zephyr wall-mounted heat pump in a condo in the Villeray–Saint-Michel–Parc-Extension sector. The client's objective was clear: to obtain responsive air conditioning in the summer, reliable heating support in the winter and the most discreet visual presence possible . We designed a custom HVAC solution that meets these expectations, while respecting the constraints specific to a Montreal condominium.

Context: needs of an urban apartment and constraints of co-ownership

The accommodation features an open living area, an adjoining bedroom, and a central hallway. Priorities:

  • Temperature stability in the day area, without drafts.

  • Low noise level for working from home.

  • Compliance with co-ownership rules : limited drilling, careful aesthetics, silent condenser outside.

  • Controlled consumption : seeking a good comfort/energy ratio.

The Zephyr wall-mounted heat pump stands out for its compact size, fine modulation and simple HVAC maintenance (washable filters, facade access).

Sizing and choosing the location of the inner head

After measuring the glass surfaces, the orientation and the internal contributions, we dimension the capacity around 9,000 to 12,000 BTU for this living area. The interior head is installed high up , in the center of a clear wall. This placement offers three advantages:

  1. Even diffusion : the air jet sweeps across the open area, reaching the kitchen and dining area without blowing directly onto the occupants.

  2. Perceived silence : at height, the sound sensation decreases and the machine can operate at low speeds most of the time.

  3. Easy maintenance : front access for cleaning filters and checking fins.

The wall bushing is positioned behind the casing to remain invisible on the inside. The drain slope is precisely adjusted to favor gravity flow towards the outside. This choice avoids the need for a lifting pump, reduces the risk of additional noise and simplifies maintenance .

Refrigeration and finishing: clean, short and durable

We are using a short refrigeration path : continuous insulated copper, shielded communication cables and compliant rigid drain . On the outside, the connections are protected by capping that matches the facade (neutral color), with bending radii respected to preserve the integrity of the pipes and limit pressure losses . Key points:

  • Sealing the hole : closed-cell foam + polyurethane sealant, reconstituted vapor barrier.

  • Stainless steel fixings and UV fasteners for durability.

  • Proximity power cut-off at the condenser for safe maintenance.

This level of finish is essential in dense neighborhoods like Montreal intra-muros , where exterior aesthetics and discretion are scrutinized by condominiums and neighbors.

Condenser installation: silence and compliance

In the common outdoor area (balcony/terrace or slab), the Zephyr condenser is placed on anti-vibration pads and wedged to ensure winter flow. Side and rear clearances are respected to optimize heat exchange. We ensure:

  • Move away from resonance points (guardrails, light walls).

  • Limit vibration transmission to the structure using suitable pads .

  • Direct the blowing away from neighboring windows when possible.

The result: a low exterior noise level , a crucial criterion in co-ownership.

Commissioning settings: precision and real comfort

Commissioning includes:

  • Vacuum draw with leak test.

  • Checking the power supply currents and voltage.

  • Setting the shutters to avoid direct flow on sensitive areas (desk, sofa).

  • Calibration of modes (cooling, auxiliary heating, dehumidification) according to customer usage.

We provide the owner with a user guide : optimal temperature ranges, cross-ventilation advice and recommendations for responsible consumption .

Result for the customer: comfort, economy and aesthetics

  • Immediate comfort : rapid temperature rise/cooling, without the sensation of drafts.

  • Lower bills : compressor-fan modulation reduces on/off cycles and optimizes energy .

  • Silence : the Zephyr head remains discreet even under sustained demand.

  • Clean wall : hidden passage, no visible chute inside, respecting the minimalist style of the condo.

Challenges encountered… and AirGreen solutions

1) Minimalist interior aesthetics
The bare white wall had to remain understated. We aligned the head as close to the ceiling as possible to minimize visual impact, centered the machine for pleasing symmetry, and masked the cutout behind the unit to avoid any visible ceiling rose.

2) Condensate management without pump
The client wanted to avoid any additional noise source. By coordinating the height of the head and the external outlet , we obtained a reliable gravity slope , tested at the end of installation (flow tests).

3) Co-ownership and neighborhood
We provided the union with the layout diagram , the condenser sound sheet and our vibration attenuation procedures . Result: project authorized quickly and work completed in one day .

Good practices for daily use

  • Auto or Low mode in the evening for optimal acoustic comfort.

  • Wide sweeping shutters in summer to distribute the cold; slightly downward tilt in winter to promote the circulation of warm air.

  • Windows closed during air conditioning; infiltration management to avoid putting unnecessary strain on the unit.

  • Free clearance around condenser (outside): no obstructions within 30–50 cm depending on the face.

AirGreen Recommended HVAC Maintenance

  • Filters : rinse every 4 to 8 weeks during periods of intensive use.

  • Annual inspection : check electrical tightening, capping , line insulation, drain and performance.

  • Periodic deep cleaning of the evaporator and condenser to maintain seasonal efficiency and prevent odors.

  • Archived maintenance report : useful for warranty and real estate resales.

We offer maintenance plans for condominiums in Montreal, Laval, Longueuil, North Shore and South Shore , to ensure consistent performance and equipment longevity.

Grants: How to maximize financial aid

Wall-mounted heat pumps with good seasonal performance and suitable cold resistance may be eligible for certain programs. Our team supports the client in:

  • verification of the criteria of the selected Zephyr model,

  • collection of documents (proof of installation, detailed invoices),

  • submission of the file within the deadlines.

This assistance simplifies the process and reduces the net cost of the project.

What you get with AirGreen

  • Condo expertise in Villeray, Rosemont, Le Plateau, Le Sud-Ouest and Ville-Marie: logistics, schedules, elevator access, protection of common areas.

  • Clean finishes : invisible interior crossings, aligned exterior capping , stainless steel screws and durable seals.

  • Complete support : choice of BTU capacity , installation, commissioning , maintenance , monitoring and support.

  • Attention to detail : vibration measurements, shutter adjustments, personalized usage recommendations.

The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).