Project

Installation of the Zephyr 25 R454B Wall-Mounted Heat Pump in Montréal-Est

Installation of the Zephyr 25 R454B heat pump in Montréal-Est by AirGreen, offering efficient heating down to -30°C and exceptional cooling down to -15°C. Enjoy a 10-year warranty and energy savings. Contact us for more info.

By AirGreen Climatisation & Chauffage Admin4 min read
Installation of the Zephyr 25 R454B Wall-Mounted Heat Pump in Montréal-Est
Installation of the Zephyr 25 R454B Wall-Mounted Heat Pump in Montréal-Est
–chapters in this story
4 minreading time
–type of installation
2025year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

Installation of the Zephyr 25 R454B Heat Pump: An Optimal Choice for Comfort Year-Round

At AirGreen, we understand that home comfort is about efficiently regulating the temperature throughout the year. That's why we offer CVAC (heating, ventilation, and air conditioning) solutions tailored to our clients' specific needs. Today, we're presenting a recent installation completed in Montréal-Est: a Zephyr 25 R454B wall-mounted heat pump. This high-performance model ensures both effective heating in winter and pleasant cooling in summer.

Installation Details: Zephyr 25 R454B

The Zephyr 25 R454B is a cutting-edge wall-mounted heat pump that offers a cooling capacity of 24,000 BTU and a heating capacity of 24,000 BTU. This model stands out with its SEER2 rating of 25, guaranteeing exceptional energy efficiency and high performance even in extreme weather conditions.

Key Features of the Zephyr 25 R454B:

  • Inverter technology for precise temperature control.

  • R454B refrigerant, an environmentally-friendly choice.

  • 10-year parts warranty, offering long-term peace of mind.

  • Low-temperature heating mode: Operates down to -30°C, ideal for the harsh winters of Montréal.

  • Cooling mode down to -15°C, providing an innovative solution for unique installations like data center cooling.

A Detailed Installation Process for Perfect Results

The installation of this Zephyr 25 R454B heat pump in Montréal-Est wasn't without its challenges. The client, a homeowner seeking a reliable heating and cooling solution for their home, needed an appliance that could withstand extreme temperatures while providing optimal comfort.

During installation, our technicians had to consider several factors, such as the placement of the outdoor unit. The unit was mounted on the building’s exterior, elevated to maximize air efficiency and ensure better thermal circulation. This placement avoided snow and ice buildup during the winter, which can affect the performance of heat pumps. The installation was carried out with constant attention to safety and adherence to all standards.

We also made sure to optimally install the piping, insulating the tubes and ensuring efficient drainage with the reversible drainage system of the Zephyr. The compressor preheating technology was another valuable feature to ensure fast startup even in extremely cold temperatures.

Why Choose the Zephyr 25 R454B?

Energy Performance and Comfort

With its SEER2 rating of 25, the Zephyr 25 R454B stands out for its ability to efficiently regulate the temperature while keeping energy costs low. This model allows for significant savings on energy bills while ensuring a stable and pleasant indoor temperature. Furthermore, with its ability to operate at temperatures as low as -30°C for heating, it's perfect for the harsh winters in Montréal, Laval, and other areas in the North and South Shores.

Reliability and Durability

The 10-year parts warranty and voltage self-adaptation technology contribute to the equipment’s longevity. This heat pump is designed to withstand voltage fluctuations from 150 to 264 volts, ensuring stability and durability even in unstable electrical environments.

Innovative Technology

The 4D auto-swing mode and the horizontal and vertical diffusion vanes allow for even air distribution throughout the room, preventing cold spots and maintaining an even temperature.

Customer Testimonial

The client, a resident of Montréal-Est, expressed satisfaction with the installation of the Zephyr 25 R454B. Here’s what they had to say after several months of use:

"The installation of the Zephyr heat pump has been an exceptional experience. Not only does it regulate the temperature perfectly in our home, but it is also extremely quiet. Additionally, the AirGreen team did an excellent job with a clean and professional installation. We now have a reliable heating and cooling system that works even in very cold weather."

Conclusion: Why Choose AirGreen for Your CVAC Installations?

At AirGreen, we are committed to providing our clients with CVAC solutions tailored to their specific needs, whether it’s a wall-mounted heat pump installation or an effective heating system for the winter. Our expertise and commitment to customer satisfaction are reflected in every project we undertake.

If you're looking for a reliable heating and cooling solution for your home or business, the Zephyr 25 R454B is an excellent choice. Contact us for a free evaluation and advice on the best system for your property.


The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment