Project

Installation of an ELIOS Central Heat Pump on the South Shore

See how the ELIOS Central Heat Pump brings year-round comfort with heating at -30°C and cooling up to 24,000 BTU. Learn about its benefits, grants, and why it’s perfect for South Shore homes!

By AirGreen Climatisation & Chauffage Admin6 min read
Installation of an ELIOS Central Heat Pump on the South Shore
Installation of an ELIOS Central Heat Pump on the South Shore
–chapters in this story
6 minreading time
–type of installation
2024year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: central heat pump, indoor module and ducts

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

  2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

  3. A shut-off switch near the outdoor unit isolates it safely for service.

  4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

  5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

  6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

  7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

  8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

The job

Experience Unmatched Comfort with the ELIOS Central Heat Pump on the South Shore

At AirGreen, we are passionate about delivering high-quality HVAC solutions tailored to the unique needs of residents across Montreal, Laval, Longueuil, North Shore, and South Shore. Our recent project on the South Shore involved installing the robust ELIOS 2-Ton Central Heat Pump, and we are thrilled to share the story behind this exciting installation.

A Closer Look at the ELIOS Central Heat Pump

1. Advanced Specifications for Maximum Performance

The ELIOS Central Heat Pump is designed to handle the diverse climate of the Greater Montreal area. Here’s why it’s an excellent choice for homes:

  • Heating Capacity: Efficient heating at temperatures as low as -30°C.
  • Cooling Capacity: Capable of cooling up to 24,000 BTU, ensuring comfortable summers.
  • Dimensions: Compact size (37.24 x 16.14 x 31.89), making it suitable for various installation scenarios.
  • Energy Efficiency:
    • 20.0 SEER for cooling
    • 12.0 HSPF for heating
    • 12.5 EER for peak efficiency
  • Sound Pressure Level: 62.0 dB(A), offering a quieter operation compared to other models.
  • Warranty Options: Comes with a 10-year warranty on parts and the compressor, with an extended 10-year labor warranty available.

2. Why South Shore Residents Chose the ELIOS System

Homeowners on the South Shore prioritize energy efficiency, quiet performance, and long-term reliability. With the ELIOS Central Heat Pump, they benefit from:

  • LogisVert Grant Eligibility: Up to $2,304 in savings through Hydro-Québec's LogisVert program, making this system both economical and sustainable.
  • Federal Grant: Additional grants of up to $5,000 make it a cost-effective option for homeowners looking to upgrade their heating and cooling systems.
  • WiFi Control: This smart feature allows homeowners to remotely manage temperatures, ensuring energy savings and convenience.
  • R-410A Refrigerant: Environmentally friendly refrigerant that complies with modern standards for sustainable HVAC solutions.

Our Installation Journey: The ELIOS Heat Pump on the South Shore

3. Site Challenges and Solutions

This installation was not without its challenges. The homeowner’s property had limited exterior space, necessitating a strategic placement of the outdoor unit. Our expert technicians performed a detailed assessment to ensure the unit would not only operate efficiently but also blend seamlessly with the home’s aesthetic.

To stabilize the unit and prevent potential issues during extreme weather conditions, we installed a custom-built platform that ensures optimal airflow and performance. We also reinforced the mounting to withstand the South Shore’s harsh winter winds.

4. Step-by-Step Installation Process

  • Initial Evaluation: Our team began with a thorough evaluation of the home’s layout and energy needs. This step is crucial for identifying the best location for the ELIOS Central Heat Pump to maximize its performance and efficiency.
  • Piping and Electrical Work: The installation required precise fitting of the 3/8 - 3/4 piping and a connection to the home’s 220V electrical system. Our certified technicians ensured all connections were leak-free and compliant with safety standards.
  • Calibration and Testing: After installation, we conducted multiple tests to ensure the system’s heating and cooling capacities were operating as expected. We calibrated the inverter compressor to modulate based on the home’s specific demands, ensuring comfort throughout the year.
  • Customer Training: We concluded with a brief training session for the homeowners, guiding them through the WiFi controls and explaining maintenance tips to keep the system running smoothly.

Benefits of Choosing AirGreen for Your HVAC Needs

5. Why Our Customers Trust Us

At AirGreen, we prioritize customer satisfaction and quality service. Here’s what sets us apart:

  • Experienced Technicians: Our team is trained to handle a wide range of installations, ensuring precision and efficiency.
  • Transparent Pricing: We provide detailed quotes, making sure there are no hidden costs. For this project, the total cost was clearly broken down, allowing the homeowner to benefit fully from the available grants.
  • Comprehensive After-Sales Support: We offer extended warranties and follow-up services to ensure your heat pump continues to perform optimally.

6. ELIOS Central Heat Pump: A Long-Lasting Investment

Investing in an ELIOS system means choosing durability and efficiency. Here are the standout features:

  • Inverter Technology: Minimizes energy consumption by adjusting the compressor’s speed to match heating and cooling demands.
  • Durable Design: Built to withstand extreme temperatures and heavy usage, this heat pump is ideal for the South Shore’s varying climate.
  • Quiet Operation: The 62.0 dB(A) sound level ensures that your outdoor spaces remain peaceful, unlike many traditional systems.

Making HVAC Upgrades Easier: Grant Opportunities

The ELIOS Central Heat Pump is eligible for multiple grants, making it an appealing choice for homeowners looking to save on their energy bills while minimizing upfront costs:

  • Hydro-Québec's LogisVert Program: Offers $2,304 in rebates.
  • Federal Programs: Grants of up to $5,000 are available, further reducing the installation cost.

Key Takeaways for Prospective Buyers

7. Top Reasons to Choose ELIOS Central Heat Pump

  • High Efficiency: Lower energy bills thanks to superior SEER, HSPF, and EER ratings.
  • Extreme Weather Performance: Reliable heating even at -30°C.
  • Available Grants: Significant financial incentives make it a smart investment.
  • Quiet and Discreet Design: Ideal for maintaining a peaceful home environment.

Conclusion: Your Comfort is Our Priority

The ELIOS Central Heat Pump is not just another HVAC unit; it’s a comprehensive solution designed to enhance home comfort and energy efficiency. Whether you're considering an upgrade or building a new home, this system delivers exceptional performance throughout the year.

Choosing AirGreen for your installation means trusting a team that values quality, customer satisfaction, and sustainable solutions. We take pride in our work and are committed to helping you make the best decision for your home’s comfort needs.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

  1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
  2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
  3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
  4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
  5. The outdoor unitOn a level base, raised above the snow, with free space all around.
  6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
  7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
  8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
  9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment