Installation of a 3-ton GREE FLEXX ULTRA R32 central heat pump in Béthanie, in the Acton RCM

187 pounds mounted on a brick wall: in Bethany, we installed a 3-ton GREE FLEXX ULTRA R32 central heat pump (34,000 BTU, 18 SEER2, -30 °C) on a wall bracket. Snow, defrost water, anchoring, A2L sensor, balance point, and LogisVert rebate.

By AirGreen Climatisation & Chauffage Admin12 min read
Installation of a 3-ton GREE FLEXX ULTRA R32 central heat pump in Béthanie, in the Acton RCM
Installation of a 3-ton GREE FLEXX ULTRA R32 central heat pump in Béthanie, in the Acton RCM
–chapters in this story
12 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: central heat pump, indoor module and ducts

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

  2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

  3. A shut-off switch near the outdoor unit isolates it safely for service.

  4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

  5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

  6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

  7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

  8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

The job

187 pounds hanging from a brick wall: the decision that shaped this entire Béthanie project

Béthanie has approximately 350 residents. It is a township municipality in the MRC d’Acton, in Montérégie, crossed by the Rivière Noire, well away from major centres. There is no natural gas, the lots are spacious, the winds are unobstructed, and snow accumulation is nothing like that on a residential street in Longueuil. It was in this context that we installed a 3-ton GREE FLEXX ULTRA R32 central heat pump, configured with GUD36AH2/G-D(U) indoors and GUD36W2/NhE-D(U) outdoors.

The final construction photo immediately shows what sets this installation apart: the outdoor unit is not resting on a slab. It is suspended from a wall bracket anchored to the home’s brick wall, approximately two feet above the stone bed. This is not an aesthetic choice. It is the choice that dictated half of the day’s technical decisions.

Why we raised the unit off the ground

Snow

A heat pump installed on low supports in a rural area of Montérégie is a machine that will spend part of February buried. An outdoor coil blocked by snow can no longer absorb heat: the defrost cycle starts more often, heating capacity drops, and the auxiliary heating takes over precisely when electricity costs the household the most. By raising the unit, we position the bottom of the cabinet clearly above the likely snow line, even after a windstorm pushes drifting snow against the wall.

Defrost water

In heating mode, a central heat pump produces water—a lot of water. Each defrost cycle drains melted ice through the bottom of the unit. On a slab attached to the house, this water freezes, builds up in layers, and eventually lifts the unit or traps the bottom of the coil in a block of ice. Here, the water falls directly into a draining stone bed, away from the pedestrian walkway. The drain elbow visible beneath the unit directs the flow toward this bed rather than along the wall.

The ground

Rural homes move. A wall bracket attached to the structure does not follow the ground’s freeze-thaw movements like a slab does. An appliance that tilts over the years operates less efficiently and vibrates more.

Hanging a 187 lb condenser on a wall: what it really requires

This is the part that many rushed installations overlook, and it is the one we pay the most attention to.

Brick is not structural. Residential brick veneer is a cladding attached to the framing with ties, with an air gap behind it. Screwing a bracket supporting 187 lb—the net weight of the GUD36W2/NhE-D(U)—into the veneer alone means loading an element that was never designed to support cantilevered weight. We anchor into the structure behind the veneer, or we use anchors rated for the combined load of the static weight and dynamic startup forces. Our internal rule is that a bracket must be rated for at least twice the weight of the unit.

Vibration. A wall is a sounding box. A compressor rigidly bolted to a wall bracket transmits its vibrations into the brick and then into the framing, and the customer hears a humming sound in the wall of a bedroom. On this job, the unit rests on anti-vibration pads placed between the feet and the support, and the tightening is checked—a bolt tightened down fully can completely negate the effect of the pad.

Level. A condenser mounted slightly askew does not drain its defrost water properly. We check the level along both axes before final tightening, not afterward.

Clearances. The unit is installed alongside an open ornamental iron fence, allowing the discharge air to pass through. A solid fence, dense cedar hedge, or shed wall placed in the same location would have recirculated hot air into the unit in summer and reduced its efficiency. The clearances specified by the manufacturer are checked with a tape measure, not by eye.

The unit: GREE FLEXX ULTRA R32, 3 tons

The FLEXX series, distributed in Quebec by Dettson, is a horizontal (side-discharge) airflow air handler powered by 24 VAC, compatible with a conventional thermostat. Configuration data for the installation in Béthanie:

  • Indoor unit: GUD36AH2/G-D(U)
  • Outdoor unit: GUD36W2/NhE-D(U)
  • Nominal capacity: 34,000 BTU/h in cooling and 34,000 BTU/h in heating
  • Modulation range: 18,000 to 37,000 BTU/h
  • Efficiency: 18 SEER2, 12 EER2, 10 HSPF2, COP 3.2
  • AHRI Number : 217120760
  • ENERGY STAR Certification
  • Heating range: down to -30 °C; cooling range: -15 °C to 54 °C
  • R32 refrigerant, 2.9 lb factory charge, precharge covering 24.6 ft of piping
  • Maximum piping length: 98.4 ft, maximum elevation difference 49.2 ft
  • Diameters: 3/8 in. liquid, 3/4 in. gas
  • Electrical: 208–230 V, MCA 5.3 A indoors, MCA 27.7 A and MOCP 30 A outdoors
  • Indoor unit: 21 1/4 x 48 1/5 x 21 1/4 in., 163.1 lb
  • Outdoor unit: 39 x 37 13/16 x 14 2/3 in., 187.5 lb, 1/6 HP fan motor
  • Factory-installed Wi-Fi and included A2L leak detection sensor

The number that matters most in Bethany is not the 18 TRÉS2. It is the -30 °C. In a municipality in the Montérégie hinterland, where January nights regularly fall below -25 °C, a heat pump that gives up at -15 °C leaves the electric heating to work alone during the most expensive weeks of the year. The ability to continue producing heat at low temperatures is what turns a good specification sheet into real savings on the bill.

“Ultra Heat” and “Dual Fuel”: what these labels change

The FLEXX is advertised as compatible with Ultra Heat and Dual Fuel configurations. In practice:

  • Ultra Heat is intended to maintain capacity in very cold weather, rather than merely being able to start.
  • Dual Fuel means that the heat pump can operate alongside a combustion heating source—useful in rural areas where many homes retain a propane furnace or wood-burning appliance. The changeover logic must then be configured: above the balance point, the heat pump operates alone; below it, the other source takes over. If improperly adjusted, this logic runs both sources at the same time, which costs more than either one alone.

In Bethany, the house runs on electricity. The FLEXX provides the main heating and air conditioning, while the existing electric heating remains as backup for peak demand.

The refrigeration circuit and the A2L label

The R32 is classified A2Lslightly flammable. Two concrete consequences on this project:

  1. The leak detection sensor integrated into the indoor unit must be positioned according to the air discharge direction. A horizontal-flow unit can be configured for left or right discharge; converting it without repositioning the sensor renders the protection ineffective. We verify the position and test the shutdown logic during commissioning.
  2. A2L warning labels affixed to the outdoor unit are not decorative. They determine how a future technician will service the unit, and they must never be removed or covered.

The brazing was performed under nitrogen, followed by a deep vacuum with a pressure-rise test before the valves were opened. The actual line-set length was recorded in the file, because that is the information the manufacturer will request if a claim ever arises.

The wall penetration and power supply

The line set penetration through the brick wall was drilled, sleeved, and then sealed with mortar—not tape, not exposed foam. An improperly sealed penetration in an exterior wall lets in air, water, and rodents, and it is one of the few imperfections a customer sees every day when walking around the corner of their house.

On the electrical side, a disconnect has been installed within sight of the unit, mounted on the support structure, with a dedicated circuit compliant with the 30 A MOCP. The power cable and low-voltage control cable are routed separately and secured neatly along the support instead of being left looped against the brick.

What we validate before recommending a central heat pump in a rural area

Five checks that change the outcome

  1. The ductwork. A central heat pump is only as good as the ductwork serving it. We measure the static pressure of the existing system before recommending a unit, because an overly restrictive system will undermine any claimed efficiency.
  2. The electrical service. In rural areas, many homes have an electrical service already burdened by electric heating, the water heater, and sometimes a well pump. The electrical load calculation is done before the sale, not on the morning of installation.
  3. The outdoor unit's orientation. Prevailing wind, snow falling from the roof, defrost-water drainage, and proximity to a bedroom window: four factors that determine where the unit should go, often contrary to the customer's first instinct.
  4. The balance point. The heating load calculation determines the temperature at which the heat pump can no longer meet the demand on its own. That value—not intuition—is what governs the backup-heating logic.
  5. Service access. A wall-mounted unit must remain accessible in winter. We verify that a technician can open the side panel without dismantling a fence.

Rebates: the current situation

The Chauffez vert program ended on March 31, 2026; in any case, it only covered conversions from heating oil and propane. Hydro-Québec's LogisVert program remains the main source of assistance for a central heat pump. The key requirements remain consistent: an ENERGY STAR unit with a valid AHRI number corresponding exactly to the installed indoor/outdoor combination, a contractor holding an RBQ licence and registered with the program, and submission of the application within the prescribed period after the invoice. The assistance is paid as a reimbursement afterward, and the amounts vary according to the unit and configuration.

The system installed here bears AHRI 217120760, listed in the file provided to the customer along with the commissioning report. This is the document that makes the difference between an approved application and one sent back.

Maintenance, in rural areas and in the city

There are two tasks we ask the homeowner to handle: clear fallen leaves from the stone bed beneath the outdoor unit in the fall, and clean the indoor filters according to the agreed schedule. Everything else—pressures, superheat, subcooling, airflow, electrical connections, and the condition of the support and pads—is covered by annual HVAC maintenance.

Why we travel as far as the Acton RCM

At AirGreen, we install central heat pumps, wall-mounted heat pumps, mini split systems, air conditioners, and air exchangers in Montreal, Laval, Longueuil, on the North Shore, on the South Shore, and in the rural municipalities of Montérégie that many contractors refuse to serve. Béthanie, Roxton Falls, Acton Vale, and the surrounding rural roads are among them.

This project summarizes how we work: the model was selected after assessing the building, the support was sized before being ordered, and the commissioning was documented. If you are considering a central heat pump, replacing a unit, or installing air conditioning for the first time in a home that has never had it, call us. We come to you, take measurements, and provide a clear proposal with the actual efficiencies, the AHRI number, and eligibility for rebates already verified.

AirGreen — Air Conditioning & Heating. RBQ 5645-9605-01. (514) 316-2973

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

  1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
  2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
  3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
  4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
  5. The outdoor unitOn a level base, raised above the snow, with free space all around.
  6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
  7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
  8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
  9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).