Installation of a Sharp BU Double Zone Heat Pump in Laval
Discover the Sharp BU Double Zone Heat Pump in Laval: A tale of innovation, comfort, and sustainability in home climate control.
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The unit’s data sheet
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp BU 24 0002 Zones (Dual Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
| Sharp BU 24 0003 Zones (Triple Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The article, chapter by chapter
A Story of Comfort and Innovation
A New Era of Climate Control
The latest installation of the Sharp BU Double Zone Heat Pump in Laval marks a significant step forward in home climate technology. This isn't just another routine installation; it's about transforming everyday living into an experience of comfort and sustainability. Here at AirGreen, we believe that the essence of a great product lies not only in its features but also in its fit and integration into the homes and lives of our clients.
The Machine: A Blend of Efficiency and Innovation
The Sharp BU model, recognized for its 24.0 SEER efficiency, stands out for its unique Plasmacluster technology and the environmentally friendly R-32 refrigerant. With two 12,000 BTU indoor units, this system effortlessly manages the climate of large spaces while keeping energy consumption in check. Let's delve into what makes this installation in Laval not just an operation but a tale of transformation.
Key Features of the Sharp BU Heat Pump
- Energy Star® Certification: Ensures optimal efficiency and environmental stewardship.
- Wi-Fi Enabled: Provides effortless control and monitoring from anywhere.
- High AHRI Certified Performance: Guarantees top-tier functionality and performance metrics.
- Comprehensive Warranty: 10 years for compressor, parts, and labor, ensuring peace of mind for homeowners.
- Low Sound Pressure Level: At just 50.0 dB(A), it ensures a quiet operation, making it ideal for residential areas.
Revolutionary Plasmacluster Technology
Unlike traditional systems, the Sharp BU incorporates Plasmacluster technology to enhance air quality alongside temperature control. This technology attacks pollutants at a molecular level, neutralizing harmful substances in the air, providing a safer and more comfortable indoor environment. It's a boon for those particularly sensitive to allergens or residing in urban areas where air quality is a concern.
Eco-Friendly R-32 Refrigerant
In our commitment to sustainability, choosing the Sharp BU with R-32 was a deliberate choice. This refrigerant not only reduces the heat pump's overall carbon footprint but also enhances its efficiency and lowers operating costs. It's a smart choice for homeowners looking to make environmentally conscious decisions without compromising on performance.
The Installation Story: Bringing Technology Home
The installation process in Laval was tailored to maximize the potential of this innovative system. Situated strategically to optimize airflow and cooling distribution, the indoor units were installed with precision. Our certified technicians ensured seamless integration with existing home layouts, preserving aesthetic appeal while upgrading functionality.
Client Impact: A Testimony to Comfort
The immediate impact on our Laval client's home was palpable. The dual-zone capability allowed for customized settings across different rooms, catering to individual comfort preferences. This level of personalization not only enhances comfort but also improves the efficiency of the system, as energy is not wasted cooling unused spaces.
Long-Term Benefits and Savings
With the 3000$ LogisVert Grant from Hydro-Québec, our client in Laval benefited not just from cutting-edge technology but also significant cost savings. The investment in a high-efficiency system like the Sharp BU pays dividends in the form of reduced energy bills and maintenance costs over time.
Conclusion: More Than Just Installation
This installation of the Sharp BU Double Zone Heat Pump in Laval by AirGreen is more than just a testament to advanced HVAC technology; it represents a commitment to enhancing the quality of life through innovative solutions. As we continue to serve the regions of Montreal, Laval, Longueuil, and beyond, our focus remains on delivering systems that offer both superior performance and meaningful environmental benefits.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).
