Job sheet · Project

Installation of a Fujitsu LPAS1 Wall-Mounted Heat Pump in Town of Mount-Royal, Montreal

Facing a too-hot second floor in summer? Dive into our latest installation story in Town of Mount-Royal, where we transformed discomfort into delight with the Fujitsu LPAS1 Heat Pump!

By AirGreen Climatisation & Chauffage Admin3 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
3 minto read the whole story
–type of installation
2023year published
At a glance

The job on one screen

Installation of a Fujitsu LPAS1 Wall-Mounted Heat Pump in Town of Mount-Royal, Montreal
Installation of a Fujitsu LPAS1 Wall-Mounted Heat Pump in Town of Mount-Royal, Montreal
The full story

The article, chapter by chapter

The Perfect Solution to a Second Floor Summer Dilemma

When faced with the challenge of a sweltering second floor, our team at AirGreen stepped in with a solution that not only met but exceeded our client's expectations. Here's the story of how we transformed a summer discomfort into a year-round haven of comfort.

The Challenge: A Too-Hot Second Floor

Our client, residing in the picturesque Town of Mount-Royal, had a central heating and cooling system that worked wonders for most of their home. However, the second floor remained a stubborn exception. Summer after summer, it transformed into a sauna, leaving the residents searching for a solution.

The Options on the Table

  1. Adapting the Central System: This involved adding more ducts to the second floor and upgrading to a more powerful central system. While it seemed like a straightforward solution, it came with a hefty price tag and the potential for significant damage to the home's structure. Economically and practically, it was a no-go.

  2. Installing a Wall-Mounted Air Conditioner: The residents initially leaned towards this option, primarily seeking a cooling solution. But when we introduced the idea of a heat pump, the game changed.

Why the Fujitsu LPAS1 Wall-Mounted Heat Pump Was the Winner

  • Government Grants: The difference in cost between a heat pump and a simple air conditioner is marginal, around $50-$100. However, the heat pump qualifies for substantial government grants: a Federal Grant ranging from $2,500 to $5,000 and a Provincial Grant of $560. This made the heat pump an economically savvy choice.

  • Top-Notch Efficiency: With a cooling capacity of 18,000 BTU and an efficiency rating of 20.0 SEER, the Fujitsu LPAS1 is designed to deliver optimal performance without burning a hole in your pocket.

  • Silent Operation: One of the standout features of the Fujitsu machine is its quiet operation. With an exterior sound pressure level of 50.0 dB(A) and an indoor level ranging between 26 and 44 dB(A), it ensures peace and tranquility alongside comfort.

  • Warranty and Assurance: The Fujitsu LPAS1 comes with a comprehensive warranty package - 10 years for the compressor, parts, and labor. Plus, an extended warranty of 10-10-10 is included, ensuring our clients have peace of mind for a decade.

  • Eco-Friendly: The machine uses R-410A gas, which is known for its eco-friendly properties, ensuring our clients make a green choice.

The Installation Process

Given the medium difficulty level of the installation, our team had to ensure precision and expertise. The client's existing central system posed some challenges, but our experienced team navigated them with ease. The result? A seamlessly integrated Fujitsu LPAS1 Wall-Mounted Heat Pump that now cools the once-too-hot second floor, making it a comfortable living space.

A Satisfied Customer

Our client was not just looking for a machine; they were seeking a solution. And that's what we delivered. By understanding their needs, presenting the best options, and executing a flawless installation, we turned a summer problem into a year-round solution. The Fujitsu LPAS1, with its impressive features and the added advantage of government grants, proved to be the perfect fit.

At AirGreen, we pride ourselves on offering HVAC solutions that are not just efficient but also economical. Serving Montreal, Laval, Longueuil, North Shore, and South Shore, we aim to ensure every client, like the one in Town of Mount-Royal, finds the perfect HVAC solution for their unique needs.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment