Installation of a Gree Vireo Gen 3 Wall-Mounted Heat Pump in Anjou, Montreal
Dive into a tale of elegance & efficiency with AirGreen’s latest installation in Anjou, Montreal! Uncover the story of a project where precision meets innovation, and customer dreams are realized.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
A Symphony of Efficiency and Elegance: Unveiling Our Latest Masterpiece
Strategic Location: Anjou, Montreal
Nestled in the vibrant district of Anjou, Montreal, our latest installation epitomizes a seamless blend of functionality and aesthetic appeal. This project was meticulously executed to meet the unique demands of our esteemed client, ensuring optimal comfort without compromising on style.
Gree Vireo Gen 3: A Paragon of Excellence
The Gree Vireo Gen 3 Wall-Mounted Heat Pump is a marvel of modern engineering, boasting a cooling capacity of 12,000 BTU and unparalleled heating performance up to -30°C. With a stellar Energy Star® rating, this unit is a testament to efficiency and sustainability.
- Serial Numbers:
- Interior: 3VIR12HP230V1AH
- Exterior: 3VIR12HP230V1AO
- Dimensions:
- Interior: 32.5 x 7.75 x 11.5
- Exterior: 35.38 x 14.75 x 23.5
- Sound Levels:
- Exterior: 52.0 dB(A)
- Interior: 27 / 43dB(A)
Balcony Brilliance: A Tale of Precision and Innovation
Our client envisioned a sophisticated installation on their balcony, a request we were more than thrilled to accommodate. This strategic placement not only preserved valuable parking space but also eliminated any potential disruption to vehicles in the vicinity.
Electrical Efficiency: A Story of Savings
With the electrical panel conveniently located adjacent to the balcony, the installation required minimal electrical wiring, translating to significant cost savings for our client. Our standard package includes 15 feet of electrical wire, making this project an exemplar of economical excellence.
Optimal Placement: Center Stage Comfort
After careful consideration and expert consultation, the decision was made to install the head unit at the very heart of the living room. This strategic positioning ensures uniform cooling during the sweltering summer months and cozy warmth in the frigid winter, providing a haven of comfort year-round.
Grants Galore: Maximizing Value
This installation qualifies for substantial grants, including a Federal Grant ranging from $2,500 to $5,000 and a Provincial Grant of $385. These incentives underscore the value proposition offered by the Gree Vireo Gen 3, making it an investment that is as financially savvy as it is functionally superior.
Customer Satisfaction: Our True North
Our client was overjoyed with the outcome of this project, expressing immense satisfaction with both the process and the final product. This installation is not just a testament to our technical expertise but also a shining example of our commitment to delivering joy and comfort to our clients.
Why AirGreen?
At AirGreen, we don’t just install HVAC units; we craft experiences. Our installations in Montreal, Laval, Longueuil, North Shore, and South Shore are symphonies of precision, efficiency, and customer satisfaction. Each project is a unique masterpiece, reflecting our dedication to quality and our relentless pursuit of excellence.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).