Installation of a SHARP ZU1 Mini Split Heat Pump in Oka, North Shore
Feel the difference with the SHARP ZU1 Heat Pump’s Plasmacluster technology – installed by AirGreen, where innovation meets home comfort.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Modern Comfort Meets Innovative Technology
At AirGreen, we pride ourselves on enhancing the comfort of homes across Montreal and Quebec with the latest in HVAC technology. Our recent installation in Oka, North Shore, showcases the cutting-edge SHARP ZU1 Mini Split Heat Pump, a model celebrated for its robust performance and advanced features. This installation not only underscores our commitment to quality but also aligns with our dedication to environmental sustainability and energy efficiency.
Unpacking the SHARP ZU1 Mini Split Heat Pump
The SHARP ZU1, with a cooling and heating capacity of 18,000 BTU, is engineered to provide exceptional comfort year-round. Its ability to operate efficiently even at -27°C makes it an ideal choice for the harsh Quebec winters. This system incorporates the revolutionary R-32 refrigerant, enhancing its eco-friendliness and efficiency, pivotal as energy standards evolve towards the 2025 regulations.
Specifications at a Glance:
- Cooling/Heating Capacity: 18,000 BTU
- Energy Efficiency: 24.0 SEER
- Interior Dimensions: 41.42 x 9.80 x 12.44 inches
- Exterior Dimensions: 33.47 x 13 x 27.94 inches
- Sound Pressure Levels: 25 dB(A) indoor, 52 dB(A) outdoor
- Advanced Features: WiFi connectivity, AHRI Certified, Energy Star® rated

Innovative Features for Optimal Comfort
Plasmacluster Technology: A Breath of Fresh Air
Unique to SHARP, the Plasmacluster technology enhances indoor air quality by neutralizing airborne bacteria, viruses, and allergens, providing a healthier living environment. This feature sets the SHARP ZU1 apart from conventional heat pumps, making it a leader in air purification.
Coanda Airflow Control: Engineered for Comfort
The Coanda effect utilized in SHARP systems ensures even air distribution throughout the room. This prevents uneven temperatures, a common issue in less advanced models, ensuring every corner of your space achieves the desired comfort level without direct airflow discomfort.
Seamless Installation Process
Our skilled technicians at AirGreen carried out the installation with meticulous attention to detail. The location in Oka posed unique challenges due to the structural layout of the residence. However, our team efficiently managed the installation, ensuring that the unit was perfectly positioned to optimize airflow and aesthetic integration into the living space.
Grant and Incentives
The homeowner benefited significantly from the LogisVert Grant from Hydro-Québec, receiving $2640, which offset a substantial portion of the installation cost. This incentive is a testament to the system's energy efficiency and the environmental benefits it offers.
Why Choose AirGreen?
At AirGreen, we not only focus on installing the most advanced and efficient HVAC systems but also on ensuring that our clients receive the best possible service and return on investment. Here’s why our installation of the SHARP ZU1 Mini Split Heat Pump in Oka is a testament to our commitment:
- Expert Installation: Our certified technicians ensure each system is installed according to manufacturer specifications and local codes.
- Cost-Efficiency: With the help of governmental grants and the high efficiency of the SHARP ZU1, our customers enjoy lower energy bills and a reduced carbon footprint.
- Long-Term Reliability: SHARP's comprehensive 10-year warranty on the compressor, parts, and labor offers peace of mind, knowing that your investment is protected.
Conclusion: Your Partner in Home Comfort
Choosing AirGreen means opting for a partner who understands the importance of comfort, efficiency, and sustainability. Our installation of the SHARP ZU1 Mini Split Heat Pump in Oka, North Shore, not only demonstrates our expertise but also our commitment to providing solutions that meet the specific needs of our clients.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).