Installation of a Sharp ZU1 Wall Heat Pump in Roxboro, Montreal
Discover how the Sharp ZU1 Wall Heat Pump transforms a Roxboro home with superior air quality and energy efficiency, elegantly installed by AirGreen.
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The unit’s data sheet
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The article, chapter by chapter
Bringing Comfort Home with Advanced Technology
When it comes to home comfort, the quality of your air conditioning and heat pump system plays a key role. AirGreen is proud to present a recent installation of the Sharp ZU1 wall-mounted heat pump, a model that promises efficiency and robust performance. Nestled in the peaceful Roxboro neighborhood of Montreal, this installation not only illustrates our commitment to superior service but also highlights the advanced features of the Sharp ZU1 model, suited to Quebec’s demanding climate.
A Closer Look at the Sharp ZU1 Installation
The chosen site for this installation was a charming residence in Roxboro, where the need for a reliable and efficient air management solution was paramount. The Sharp ZU1 wall-mounted heat pump, with a capacity of 15,000 BTU and equipped with the latest inverter technology, was selected to ensure optimal comfort throughout the year.
Key Features of the Sharp ZU1 Wall-Mounted Heat Pump:
- Cooling and Heating Capacity: Efficiently handles a range of temperatures, extending even to extreme conditions down to -27°C, thanks to its robust construction.
- Energy Efficiency: With a SEER rating of 24.0, this model is one of the most energy-efficient on the market, significantly reducing household energy consumption.
- Eligibility for Provincial Subsidy: This installation qualifies for a LogisVert subsidy of $2,172 from Hydro-Québec, the highest available for any 15,000 BTU mini split in Quebec, making it an economically attractive option.
- Advanced Features: Includes Wi-Fi connectivity, Plasmacluster ionic technology for air purification, and Coanda airflow control for even temperature distribution.

Cutting-Edge Technology for Superior Comfort
The Sharp ZU1 heat pump is not just a heating device; it is a gateway to an enhanced home life. This model incorporates several advanced technologies that set it apart from the competition:
- Plasmacluster Technology: This feature stands out by purifying indoor air by neutralizing airborne pathogens such as bacteria and viruses, as well as allergens and mold, making it a boon for health-conscious homeowners.
- Coanda Airflow Control: The unit uses the Coanda effect to optimize air distribution in the room, ensuring uniform temperatures without direct drafts on occupants, thus enhancing comfort levels.
- Inverter Technology: The Sharp ZU1’s inverter technology allows the unit to adjust its performance based on real-time temperature detection, saving energy while maintaining consistent indoor climate control.
Installation Process and Customer Experience
The installation process was meticulously planned to ensure minimal disruption for the homeowner. AirGreen’s certified technicians managed the setup with precision, ensuring that the outdoor and indoor units were installed efficiently and neatly. The strategic placement of the outdoor unit and careful routing of cables and pipes demonstrate our attention to detail and commitment to both aesthetics and functionality.
Customer Feedback: The homeowners were particularly impressed by the immediate improvement in air quality and the quiet operation of the unit. The Sharp ZU1’s user-friendly interface, combined with smart features like remote monitoring and control via a smartphone app, provided them with unprecedented convenience and control over their home environment.
Why Choose AirGreen for Your HVAC Needs?
AirGreen positions itself at the forefront of HVAC solutions in Montreal, offering cutting-edge technology and personalized service. Whether you are looking to install a new system or upgrade an existing one, our team is equipped to provide top-tier advice and services tailored to your specific needs. Here’s why you should consider us for your next HVAC project:
- Expertise and Reliability: With many years of experience in the industry, our qualified technicians ensure every installation is done right the first time.
- Customer-Focused Approach: We prioritize customer satisfaction above all, offering detailed consultations and transparent communication throughout the installation process.
- Innovative Solutions: We stay up to date with the latest HVAC technologies to provide our clients with the most efficient and reliable systems available.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).