Installation of a Sharp ZU1 Mini Split Heat Pump in Sainte-Marthe-sur-le-Lac
Discover the latest Sharp ZU1 installation by AirGreen in Sainte-Marthe-sur-le-Lac, offering unmatched comfort, energy savings, and up to $2,172 in grants for your HVAC needs.

Take a tour of the installation
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
The Ideal Blend of Innovation and Comfort with AirGreen's Latest Installation
When it comes to keeping homes in Greater Montreal and surrounding areas comfortable year-round, AirGreen continues to set the standard. Our latest installation in Sainte-Marthe-sur-le-Lac featured a 15,000 BTU Sharp ZU1 Mini Split Heat Pump, a perfect blend of cutting-edge technology and eco-friendly performance. This project not only enhances the home's climate control but also qualifies for a $2,172 LogisVert Grant from Hydro-Québec, making it a smart and sustainable choice for any homeowner.
Bringing Efficiency and Comfort to Sainte-Marthe-sur-le-Lac
This particular installation involved integrating a 15,000 BTU Sharp ZU1 Mini Split Heat Pump into a modern residence in Sainte-Marthe-sur-le-Lac, located just outside the bustling city of Montreal. The customer was seeking a solution that would provide year-round comfort, especially during Quebec's harsh winters, where temperatures can plummet as low as -27°C. The Sharp ZU1's heating capacity and advanced features made it the perfect choice to meet these needs.
Why the Sharp ZU1 Mini Split is the Top Choice
The Sharp ZU1 is not just another mini split heat pump; it is an eco-friendly and high-performance system equipped with R-32 refrigerant, which significantly reduces its global warming potential compared to traditional refrigerants like R-22. Its energy efficiency is further complemented by a 24.0 SEER rating, ensuring cost-effective heating and cooling throughout the year. Whether in Sainte-Marthe-sur-le-Lac, Montreal, or other parts of the North Shore and South Shore, this system adapts to Quebec's extreme weather conditions, providing a reliable source of comfort and energy savings.
Plasmacluster Technology: Clean Air for a Healthier Home
One of the key highlights of the Sharp ZU1 is its Plasmacluster technology, which goes beyond mere temperature control. This unique system releases ions identical to those found in nature, helping to neutralize airborne bacteria, viruses, mold, and other harmful particles. For homeowners in Sainte-Marthe-sur-le-Lac, this means a home that is not only comfortable but also healthier, with superior indoor air quality that stands out in the market.
The Installation Process: Precision and Expertise
At AirGreen, we approach each installation with a commitment to quality and customer satisfaction. The project began with an on-site consultation to assess the home’s layout, ensuring the optimal placement of the Sharp ZU1 unit for maximum efficiency. The interior unit, with its sleek dimensions of 41.42 x 9.80 x 12.44 inches, was mounted in a location that allowed the Coanda airflow control to distribute air evenly across the living spaces.
For the exterior unit, measuring 30.72 x 10.59 x 21.25 inches, we made sure to position it in a way that maximized accessibility for future maintenance while protecting it from harsh winter elements. The installation included connecting high-quality refrigerant pipes (1/4 - 3/8) and configuring the 220V electrical system to support the unit’s power needs.
Sharp ZU1: A Heat Pump Built for Quebec's Cold Climate
The Sharp ZU1 Mini Split Heat Pump is designed to perform exceptionally well in cold climates, which is why it comes with Energy Star® certification for cold-climate operation. Its -27°C heating capacity ensures that homeowners will stay warm even on the coldest days, while its inverter technology adjusts the unit's output to maintain a consistent indoor temperature, thereby reducing energy consumption and utility costs.
Advanced Defrosting Features for Enhanced Reliability
Another significant advantage of the Sharp ZU1 is its hot gas pipe defrosting system, which circulates hot gas to prevent the outdoor compressor from freezing. This advanced feature significantly reduces defrosting time by up to 60%, helping to maintain a comfortable indoor temperature even during extended cold snaps.
The Environmental Advantage: A Greener Choice for Homeowners
At AirGreen, we believe in providing solutions that are not only efficient but also environmentally responsible. The use of R-32 refrigerant in the Sharp ZU1 reduces its carbon footprint and contributes to fighting climate change. The Energy Star® certification and SEER rating of 24.0 further emphasize the unit’s energy efficiency, ensuring that homeowners can enjoy eco-friendly comfort without compromising on performance.
Qualifying for the LogisVert Grant: The Highest Available for 15,000 BTU Systems
Homeowners who choose the Sharp ZU1 benefit not only from its cutting-edge features but also from significant financial incentives. The $2,172 LogisVert Grant from Hydro-Québec is the highest available for any 15,000 BTU mini split in Quebec, making this system an economically sound choice. This grant helps offset the initial installation costs, allowing homeowners to invest in a quality system while taking advantage of government support.
Smart Connectivity and User-Friendly Features
In today’s digital age, having a smart HVAC system is more important than ever. The Sharp ZU1 offers WiFi connectivity, allowing homeowners to control the system remotely via a smartphone app. The app provides real-time updates on temperature, humidity, and energy consumption, empowering users to make informed decisions about their energy use.
GPS Interlocking for Enhanced Energy Management
One of the standout features is the GPS interlocking function, which automatically adjusts the system based on the homeowner's proximity to the house. This means that the Sharp ZU1 can prepare the home’s climate before arrival, ensuring a comfortable indoor environment while reducing energy waste.
A Customer Experience That Sets Us Apart
At AirGreen, we pride ourselves on delivering not just top-quality installations but also an exceptional customer experience. From the initial consultation to the final installation and system testing, our team ensures that every step is handled with precision and care. The installation in Sainte-Marthe-sur-le-Lac was no exception, and the homeowners were delighted with their new Sharp ZU1 Mini Split Heat Pump, which now provides them with year-round comfort and peace of mind.
Why Choose AirGreen for Your HVAC Needs?
- Expertise in Extreme Climate Solutions: With years of experience, we know how to handle Quebec's challenging climate.
- Comprehensive Warranty Coverage: The Sharp ZU1 comes with a 10-year warranty on the compressor, parts, and labor, providing long-term peace of mind.
- Top-Notch Customer Service: We offer ongoing support, from routine maintenance to emergency repairs, ensuring your system runs smoothly for years to come.
- Sustainable and Eco-Friendly Options: At AirGreen, we prioritize green technologies that offer energy savings and environmental benefits.
The unit on this job, in figures
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The big day, step by step
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What would it look like at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Four mistakes we do not make
Flip each card to see what we do instead.
Your own project, step by step
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Every house has its constraints. We see them before we install.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).