The job on one screen

The unit’s data sheet
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The article, chapter by chapter
A Modern Solution for Efficient Heating and Cooling in Verdun
At AirGreen, we pride ourselves on delivering top-notch HVAC services across Montreal, Laval, Longueuil, North Shore, and South Shore. Recently, we had the pleasure of completing an installation in Verdun, where we installed a Sharp ZU1 Wall-Mounted Heat Pump. This installation was not just about placing a machine; it was about enhancing the comfort and energy efficiency of our client's home. Here’s a detailed look into this installation and why the Sharp ZU1 is a remarkable choice for any household.
Installation Overview
- Location: Verdun
- Type of Machine: Wall-Mounted Heat Pump
- Brand: Sharp
- Model: ZU1
- Size: 24,000 BTU
- Grant Eligibility: $2688 (LogisVert grant by Hydro-Québec)
- Energy Star®: Yes
- WiFi: Included
- AHRI: 213246054
- Efficiency: 22.0 SEER
- Warranty: 10 years on compressor, parts, and labor
- Pipes: 1/4 - 3/8
- Voltage: 220V
- Sound Pressure Level (Exterior): 53.0 dB(A)
- Sound Pressure Level (Interior): 25 / 49 dB(A)
- Gas (Freon): R-32
- Cooling Capacity: 24,000 BTU
- Heating Capacity: -27°C
- Serial Numbers: Interior - AY-XP24ZU1, Exterior - AE-X24ZU1
- Dimensions: Interior - 41.42 x 9.80 x 12.44 inches, Exterior - 33.47 x 13 x 27.94 inches

The Sharp ZU1: A Green and Efficient Choice
The all-new Sharp ZU1 Wall-Mounted Heat Pump stands out as one of the first models to use the eco-friendly R-32 freon. This system is designed to be more energy-efficient and is aligned with the new government energy efficiency standards set to come into effect in 2025. By choosing the Sharp ZU1, our clients are investing in a greener future, ensuring both environmental sustainability and significant energy savings.
Advanced Features for Superior Performance
Plasmacluster Technology: Purifying the Air You Breathe
One of the standout features of the Sharp ZU1 is its Plasmacluster Technology. This innovative technology replicates natural air purification processes, effectively neutralizing airborne bacteria, viruses, mold, and other contaminants. This ensures that the indoor air quality is significantly improved, contributing to the health and well-being of the occupants.
Key Benefits of Plasmacluster Technology:
- Eliminates airborne viruses and bacteria.
- Removes mold and other airborne microbes.
- Fights odors, including tobacco residue.
- Reduces airborne allergens.
The process involves the diffusion of ions which attack and destroy contaminants, transforming them back into water and humidity, thus purifying the air efficiently.
Coanda Airflow Control: Uniform Comfort Across Your Home
The Coanda airflow control mechanism is another feature that sets the Sharp ZU1 apart. By leveraging the natural Coanda effect, the system ensures uniform temperature distribution throughout the home, avoiding direct airflow onto the occupants. This not only enhances comfort but also ensures energy-efficient operation.
Hot Gas Pipe System: Unmatched Performance in Extreme Cold
The Hot Gas Pipe System, patented by Sharp, allows the ZU1 heat pump to operate efficiently in extreme cold, down to -27°C. This technology prevents the outdoor compressor from freezing, ensuring continuous and reliable heating even during the harshest Quebec winters.
Installation Experience: A Case Study from Verdun
Our recent installation in Verdun showcases the meticulous planning and execution that goes into every AirGreen project. The Sharp ZU1 was installed on the exterior wall, ensuring optimal placement for both efficiency and aesthetics. The WiFi connectivity feature was a hit with the homeowner, who can now control and monitor the system remotely via a smartphone app.
Why Choose AirGreen for Your HVAC Needs?
At AirGreen, we are committed to providing our clients with the best HVAC solutions tailored to their specific needs. Our team of experts ensures that each installation is performed with precision and care, guaranteeing satisfaction and optimal performance.
Benefits of Choosing AirGreen:
- Expertise in the latest HVAC technologies.
- Professional and friendly service.
- Comprehensive warranties and after-sales support.
- Environmentally sustainable solutions.
Conclusion
The Sharp ZU1 Wall-Mounted Heat Pump installed in Verdun is a testament to our commitment to quality and customer satisfaction. With advanced features like Plasmacluster Technology, Coanda Airflow Control, and the Hot Gas Pipe System, this heat pump offers unparalleled performance and comfort. Coupled with the LogisVert grant and its impressive energy efficiency, it’s a smart investment for any homeowner.
If you are looking for a reliable and efficient HVAC solution, look no further than AirGreen. Contact us today to learn more about our services and how we can help you achieve the perfect indoor climate.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).