In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Elevating Comfort with AirGreen's Latest Installation: The Sharp BU Triple Zone Heat Pump in Plateau-Mont-Royal
When it comes to reliable heating and cooling solutions, AirGreen consistently delivers top-notch services across Montreal, Laval, Longueuil, the North Shore, and South Shore. Our latest installation in Plateau-Mont-Royal showcases the power and efficiency of the Sharp BU Triple Zone Heat Pump, designed to cater to the unique climate challenges of the area. This recent project involved installing a 24,000 BTU compressor with three 9,000 BTU indoor units, providing a tailored solution for multi-zone temperature control.
Meeting Local Needs with High-Performance HVAC
In the heart of Plateau-Mont-Royal, known for its vibrant communities and historic charm, homeowners face unique comfort needs. The fluctuating temperatures and humid conditions call for an HVAC system that adapts effortlessly to seasonal changes. The Sharp BU Triple Zone Heat Pump was selected for this very reason, offering superior cooling capabilities in the summer and efficient heating down to -27°C during harsh winters. With Energy Star® certification and a 24.0 SEER rating, this installation ensures not only comfort but also long-term savings on energy costs.
Installation Challenges and Solutions
The installation site, a cozy apartment in Plateau-Mont-Royal, presented a few challenges that our team expertly navigated. With the building's older architecture, there were limited options for placing the outdoor unit without compromising aesthetics or functionality. We managed to install the 33.47 x 13 x 27.94-inch exterior unit discreetly, ensuring it blended seamlessly with the building's exterior. To maintain the apartment's clean and modern interior look, we mounted the indoor units in strategic locations for optimal air distribution, thanks to SHARP's Coanda effect technology.

A Deeper Look into the Features: What Makes the Sharp BU Triple Zone Stand Out?
Advanced Plasmacluster Technology for Cleaner Air
One of the standout features of the Sharp BU Triple Zone Heat Pump is its Plasmacluster air purification technology. This system releases positive and negative ions to neutralize airborne pathogens, including bacteria, viruses, and mold. It also helps eliminate common household odors from cooking, pets, or tobacco, keeping indoor air fresh and inviting. The homeowners were particularly pleased with this feature, as it significantly improved air quality, benefiting family members with allergies and asthma.
R-32 Refrigerant for Environmental Efficiency
AirGreen is committed to sustainable practices, which is why the choice of R-32 refrigerant was ideal for this project. With a lower Global Warming Potential (GWP) compared to traditional refrigerants like R-22 or R-410A, R-32 reduces the environmental impact of heating and cooling systems. Moreover, its energy-efficient properties allow for better heat transfer, which translates to lower energy consumption and cost savings.
Harnessing the Coanda Effect for Optimal Comfort
The Coanda effect, a key feature in Sharp's technology, revolutionizes indoor air distribution. Instead of blowing air directly onto occupants, the heat pump uses this effect to direct air along walls and ceilings, resulting in even temperature distribution. This unique approach avoids drafts and creates a more consistent climate throughout the space. The homeowners reported feeling more comfortable immediately after the system was up and running, with no hot or cold spots in the apartment.
Exceptional Cold Weather Performance: The "HOT GAS PIPE" System
Montreal winters are notoriously harsh, with temperatures frequently dipping below freezing. The Sharp BU Triple Zone Heat Pump is equipped with the patented "HOT GAS PIPE" system, which ensures reliable heating even in extreme cold. By utilizing residual heat during the defrosting process, this system prevents ice buildup on the outdoor unit, maintaining optimal performance down to -27°C. This feature not only ensures year-round comfort but also enhances the system's energy efficiency by minimizing heat loss.
Installation Highlights: Bringing State-of-the-Art HVAC Solutions to Plateau-Mont-Royal
- Location: Plateau-Mont-Royal, a lively and culturally rich neighborhood in Montreal.
- System Details: Sharp BU Triple Zone Heat Pump with a 24,000 BTU compressor and three 9,000 BTU indoor units.
- Energy Efficiency: 24.0 SEER, Energy Star® certified, and R-32 refrigerant for lower environmental impact.
- Heating Capability: Effective down to -27°C, thanks to the HOT GAS PIPE system.
- Air Quality Improvement: Utilizes Plasmacluster technology to neutralize pathogens and remove odors.
- Grant Eligibility: Qualifies for a $3,000 LogisVert Grant by Hydro-Québec, making it a cost-effective choice for homeowners.
Why Choose AirGreen for Your HVAC Needs?
At AirGreen, we understand that every project comes with its own set of challenges and requirements. Our team takes pride in providing tailored HVAC solutions that not only meet the demands of the local climate but also enhance the quality of life for our customers. The Sharp BU Triple Zone Heat Pump installation in Plateau-Mont-Royal is a testament to our commitment to excellence, blending cutting-edge technology with expert craftsmanship. We ensure each installation is carried out with precision, from the placement of the units to the optimization of the system's performance.
Customer Experience: A Satisfied Homeowner's Perspective
Our customer was thrilled with the results, noting how the new system transformed their living space. They immediately felt the difference in air quality, and the home's temperature remained stable and comfortable throughout. The added benefit of the self-cleaning function also provided peace of mind, knowing that the indoor air would stay free from mold and allergens.
Key Takeaways from This Installation
- The Triple Zone configuration allows for customized comfort across multiple rooms, providing flexibility in temperature control.
- The Plasmacluster air purification system significantly enhances indoor air quality.
- Energy savings are achieved through R-32 refrigerant and a high SEER rating, reducing long-term operational costs.
- The HOT GAS PIPE system ensures reliable performance during cold Montreal winters.
- Homeowners can benefit from a $3,000 LogisVert Grant, making the Sharp BU a smart investment.
Conclusion: Setting a New Standard for Home Comfort in Plateau-Mont-Royal
The installation of the Sharp BU Triple Zone Heat Pump by AirGreen marks a new era of comfort and efficiency in Plateau-Mont-Royal. By combining innovative technology, environmental responsibility, and superior craftsmanship, we continue to set the standard for HVAC services in the region. Whether you're looking to upgrade your existing system or install a new one, trust AirGreen to deliver a solution that meets your needs and exceeds your expectations.
How it goes, from the first call to the end
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What the unit delivers when it is cold
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp BU 24 0002 Zones (Dual Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
| Sharp BU 24 0003 Zones (Triple Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
And at your place?
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
Which type of equipment for your project?
Pick what looks like your need.
Four mistakes we do not make
Flip each card to see what we do instead.
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
Useful pages for what comes next
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
Tell us about your house. We come and see it for free.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).