Project

Installation of a MIDEA EVOX G3 Central Heat Pump in Mercier–Hochelaga-Maisonneuve

HVAC installation of a MIDEA EVOX G3 central heat pump in Mercier–Hochelaga-Maisonneuve. A high-performance, subsidized solution adapted to Montreal winters with AirGreen expertise.

By AirGreen Climatisation & Chauffage Admin5 min read
Installation of a MIDEA EVOX G3 Central Heat Pump in Mercier–Hochelaga-Maisonneuve
Installation of a MIDEA EVOX G3 Central Heat Pump in Mercier–Hochelaga-Maisonneuve
–chapters in this story
5 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: central heat pump, indoor module and ducts

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.

  2. The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.

  3. A shut-off switch near the outdoor unit isolates it safely for service.

  4. Sitting on the indoor module, it moves heat between the house air and the refrigerant.

  5. Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.

  6. Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.

  7. It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.

  8. It runs the heat pump and the backup heat. It must be compatible with the installed system.

The job

A Complete Transformation of Residential Comfort in the Heart of Mercier–Hochelaga-Maisonneuve

At AirGreen, every HVAC installation is an opportunity to solve concrete challenges while optimizing comfort and energy efficiency. In this project completed in Mercier–Hochelaga-Maisonneuve, we installed a MIDEA EVOX G3 1.5-ton (18,000 BTU) central heat pump in a typical single-family home in the area, with a challenging outdoor configuration and very real space constraints.

From the first visit, our team identified a key issue: the outdoor unit had to be installed in a restricted space, between two brick walls, with already established vegetation and limited air circulation. This type of situation is common in densely built neighborhoods of Montreal, and requires a precise technical approach to ensure the long-term performance of the system.


A Central Heat Pump Designed for Quebec's Climate

Exceptional Performance Down to -30°C

The MIDEA EVOX G3 is specifically designed for Quebec's harsh winters. Unlike many standard systems, it maintains stable heating capacity even when temperatures drop drastically.

Key technical features:

  • Heating Capacity: 18,000 BTU down to -30°C
  • SEER2: 19.0
  • HSPF2: 10.1
  • EER2: 12.5
  • ENERGY STAR® (cold climate) Certification
  • Eco-friendly refrigerant R-454B
  • Outdoor sound level: 56.5 dB(A)

This level of performance allows homeowners to reduce their reliance on auxiliary systems while maintaining constant comfort, even during cold snaps in Montreal, Laval, or on the South Shore.


Project Analysis: Constraints and Custom Solutions

Optimized Exterior Wall Installation

In this project, the installation of the outdoor unit represented the main technical challenge. The available space was:

  • Narrow (wall corner)
  • Partially obstructed by branches
  • Located near a metal railing

We opted for an installation on reinforced wall brackets, in order to:

  • Avoid ground vibrations
  • Protect the unit from snow accumulation
  • Maximize air circulation around the condenser

Our refrigeration technicians also adjusted the installation height to ensure optimal hot air exhaust in heating mode, a detail often overlooked but crucial for winter performance.

Piping and Drainage Management

The system requires 3/8 - 3/4 piping, which we carefully integrated along the exterior wall with complete mechanical protection. The challenge here was twofold:

  1. Maintain a clean and discreet aesthetic
  2. Ensure perfect insulation against thermal losses

We also installed a secure drainage system, essential to prevent water accumulation and the risk of freezing in winter.


Indoor Installation: Integration into an Existing System

Adaptation to a Typical Residential Configuration

The house was already equipped with a forced-air duct network. We therefore integrated the MIDEA EVOX G3 with a MAUSE-H18B-2A air handler, compatible with existing installations.

The advantages of this approach:

  • Reduced installation costs
  • Less invasive work
  • Optimized airflow in all rooms

Flexible Configuration

The indoor unit allows several configurations:

  • Upflow
  • Downflow
  • Horizontal left/right

In this specific case, we opted for an upflow configuration, ideal for uniform air distribution on the upper floors.


Concrete Energy Efficiency for the Client

LogisVert Subsidy: $1764

This project is eligible for a $1764 subsidy, which represents a significant financial advantage for the client.

At AirGreen, we systematically assist our clients with:

  • Eligibility verification
  • Document preparation
  • Submission of the application

Reduced Energy Consumption

Thanks to its high efficiency, the central heat pump allows for:

  • A significant reduction in heating costs
  • Better management of air conditioning in summer
  • Consistent thermal stability

Technical Details of the Installation

Complete Specifications

  • Outdoor model: MO1HE-H18B-2A
  • Indoor model: MAUSE-H18B-2A
  • Voltage: 220V
  • WiFi: Included
  • Outdoor dimensions: 35 x 13.5 x 26.5 inches
  • Indoor sound level: 37 / 42.5 dB(A)

Exceptional Warranty

  • Compressor: 12 years
  • Parts: 12 years
  • Labor: 10 years

This comprehensive coverage reflects the system's reliability and our commitment to customer satisfaction.


Common Errors Avoided in This Project

Over the years, we have identified several common errors in similar HVAC installations:

  • Installing the outdoor unit too close to a wall (poor ventilation)
  • Neglecting duct insulation
  • Undersizing the system's capacity
  • Ignoring drainage management in winter

In this project, each of these errors was carefully avoided through rigorous planning and precise execution.


Why Choose AirGreen for Your HVAC Installation in Montreal

An Approach Based on Field Expertise

At AirGreen, we don't just install systems. We analyze each situation to offer a truly adapted solution.

Our commitments:

  • Free on-site estimate
  • No payment until complete satisfaction
  • Certified and experienced refrigeration technicians
  • Fast and efficient after-sales service

A Strong Local Presence

We operate daily in:

  • Montreal
  • Laval
  • Longueuil
  • North Shore
  • South Shore

This proximity allows us to understand the specific realities of each neighborhood, as here in Mercier–Hochelaga-Maisonneuve.


Final Result: Durable and Smart Comfort

At the end of the installation, the client benefits from:

  • A quiet and efficient system
  • Smart control via WiFi
  • Stable temperature throughout the house
  • Significant energy savings

This project perfectly illustrates how a MIDEA EVOX G3 central heat pump can transform the comfort of a Montreal home, even under complex installation conditions.

At AirGreen, every detail counts — and that's what makes the difference.

The unit

The unit on this job, in figures

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Midea EVOX G3 · 1.5 tons14,70018,600−30 °C: 11,8002.1219.010.1$1,764
Midea EVOX G3 · 2 tons20,80020,600−30 °C: 12,1002.1418.610.0$2,496
Midea EVOX G3 · 2.5 tons24,00033,200−30 °C: 17,9001.9717.210.8$2,880
Midea EVOX G3 · 3 tons33,00037,400−30 °C: 27,6001.918.010.0$3,960
Midea EVOX G3 · 4 tons39,50048,000−30 °C: 27,2002.017.59.5$4,740
Midea EVOX G3 · 5 tons45,00054,000−30 °C: 37,3001.917.59.5$5,400

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.

  1. The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
  2. The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
  3. Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
  4. The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
  5. The outdoor unitOn a level base, raised above the snow, with free space all around.
  6. The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
  7. Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
  8. Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
  9. The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour electric furnace, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Check the indoor module's filter.
    • Clear winter debris from the outdoor unit.
    • Test cooling before the heat arrives.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. A central heat pump uses the house's ducts.

    2. In extreme cold, electric backup heat can take over.

    3. The filter only gets changed when the unit breaks down.

    4. You can reuse the old unit's size without checking.

    Frequently asked questions

    What people ask us about this kind of work

    11 questions
    Can I keep my current ducts?
    Often, yes: the central heat pump connects to the existing ducts. We check their condition and size during the estimate.
    What happens in extreme cold?
    The indoor module (furnace or air handler) works with the central heat pump and takes over in extreme cold.
    Furnace, air handler, ducted: what is the difference?
    The furnace or air handler is the indoor module of the central system. A ducted system hides in the ceiling: all you see are small supply grilles.
    Are there grants?
    Depending on the equipment and your situation, assistance programs may apply. AirGreen checks the exact combination before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city. See permits and by-laws, and we check for your address.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Will my current thermostat work?
    Not always: the thermostat has to run the heat pump and the backup heat. We check compatibility during the estimate.
    Central or wall units: which one?
    If the house has ducts in good shape, a central system heats and cools every room at once. Without ducts, wall units or a multi-zone are often simpler. We compare on site.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment