Smart heating in Québec: what the word means, from the compressor to Hydro-Québec peaks
The gist
"Smart" heating comes in three layers: the kWh price during Hydro-Québec peaks (Rate D, Winter Credit, Flex D), a compressor that slows down instead of stopping, and controls documented by each manufacturer. Real examples sold by AirGreen.
In detail
"Smart" heating comes in three layers. Here is what each one does, with the numbers.
The word "smart" appears in no certificate. What can be measured is a compressor that slows down instead of stopping, controls that set the temperature for you, and a kWh price that changes during Hydro-Québec peaks. This page shows all three, with units sold by AirGreen and the prices published by Hydro-Québec.
The price of the hour
Hydro-Québec changes the value of a kWh during winter peaks. A programmed control takes it into account for you.
A peak dayThe compressor
A variable-speed compressor slows down instead of stopping. The certificates publish how far.
Slowing down, in numbersThe controls
Remote, thermostat, app: what each manufacturer documents, and what it does not say.
Line by line


A January peak day, hour by hour
From December 1 to March 31, Hydro-Québec can announce peak events between 6 and 10 a.m. and between 4 and 8 p.m. Pick a rate option, then move the hour: the chart shows what a kWh is worth at that moment, per the April 1, 2026 rate grid.
Prices before taxes, Hydro-Québec rate grid of April 1, 2026 (s. 2.5, 2.64 and 2.72). Network access charge: 46.154¢ per day in all three cases. The chart shows a day with an event announced in each window; most winter days have none.
Slowing down instead of stopping: what the certificates publish
A variable-speed compressor follows the house's demand: it goes down to its minimum capacity when it is mild and up to its maximum capacity in deep cold. Pick a temperature: each band runs from the certified minimum to the certified maximum, and the yellow tick marks the rated capacity.
What each manufacturer documents, line by line
Three ways to control heating, three documents. When a document says nothing on a point, the cell says so too: silence does not mean absence.
| Layer | Central heat pumpARCOAIRE | Wall heat pumpFUJITSU AIRSTAGE | Baseboards and thermostatMYSA |
|---|---|---|---|
| The example | |||
| Example sold by AirGreen | ARCOAIRE QuietComfort Compact 3 tonsD5CUHAH36AAK + D5FUAAH36XAK | FUJITSU AIRSTAGE ORION XLTH 12,000ASUH12KZAS + AOUH12KZAH1 | MYSA for electric baseboards V2installed on existing baseboards |
| The machine | |||
| Compressor | Inverter that "continually adjusts its speed"brochure DLS-045-AR-00; 11,000 to 48,000 BTU/h at 8.3 °C per NEEP | Variable speed3,500 to 23,600 BTU/h at 8.3 °C per NEEP | None: the baseboard is a resistance |
| Heat per kWh at 8.3 °CNEEP-certified COP, at maximum then at minimum | 3.22 to 4.88 | 3.07 to 5.13 | 1, at any output |
| The controls | |||
| Control supplied | Not stated in the brochure | Backlit wireless remote, included | The MYSA thermostat replaces the baseboard thermostat |
| Wall control | Wall thermostatthe brochure names no model | FUJITSU AIRSTAGE wall controls (KAGAMI, wired) or a 24 V thermostat through the UTY-TTRXZ1 interface, optional | It is the wall thermostat itself, at 120/240 Vup to 3,800 W at 240 V |
| App and Wi-Fi | Not stated by the manufacturer | Built-in Wi-Fi, AIRSTAGE Mobile app | 2.4 GHz Wi-Fi, MYSA app |
| Voice assistants | Not stated by the manufacturer | Not stated in the sheet consulted | Google Home, Alexa, Apple HomeKit |
| Modes and sensors | Not stated by the manufacturer | Economy, Energy Saving, Powerful, Minimum Heat and Occupancy | Humidity sensor, energy monitoring |
| Link with other equipment | Dual fuel: switches to an oil or gas furnace based on the outdoor temperature | External inputs and outputs, to coordinate backup heat | Controls the baseboard circuit it is installed on |
| The grid | |||
| Feature specific to Hydro-Québec peak eventsthe response comes from the schedule and set point | Not stated by the manufacturer | Not stated by the manufacturer | Not stated by the manufacturer |
Columns in alphabetical order of brands. No row is highlighted: the right control depends on the system already in place.
The questions people ask us
Does a "smart" unit use less energy?
The word has no definition in the certificates. What is measured is the HSPF2, the SEER2 and the COPs published by AHRI and NEEP: an app or Wi-Fi does not change them. What controls change is the timing and the set point: heating less during a peak window, or not heating an empty room.
Do I need an app to use Flex D or the Winter Credit?
No. Both options apply to your electricity account: any drop in consumption during an event counts, whether it comes from a schedule, an app or a manual setting. Hydro-Québec sends its event notices by email; a valid address must be on file in your Customer Space.
Winter Credit or Flex D: what is the difference?
With the Winter Credit, you pay the Rate D price and receive 58.490¢ per kWh curtailed during an event, calculated against your reference consumption. With Flex D, a winter kWh costs less outside events (4.886¢ and 9.103¢) and more during an event (46.463¢). We do not choose for you: Hydro-Québec publishes both options and their conditions.
Does my heat pump stop during a peak event?
These rate options do not stop any equipment: they change the price of a kWh or add a credit. What the unit does depends on your settings. A variable-speed heat pump can also slow down rather than stop; the certificates publish its minimum capacity.
Is a smart thermostat enough for baseboards?
For electric baseboards, the thermostat must run at 120/240 V: that is the case of the MYSA for baseboards V2, which does not suit 24 V systems. Our page on smart thermostats details the wiring, system by system.
What about dual fuel with a gas or oil furnace?
The ARCOAIRE brochure describes an automatic switch to an oil or gas furnace based on the outdoor temperature. Work on gas or oil appliances, boilers and hydronic systems is handled by a licensed partner; AirGreen (RBQ licence 5645-9605-01) handles the heat pump, ventilation, refrigeration and electrical work.
We look at your heating before talking controls.
Heat pump, baseboards or ducts: the estimate visit is free and the quote arrives within 24 hours.
Documents consulted
Data verified on November 17, 2026. Every value comes from a manufacturer document, named in the list above. When a document says nothing on a point, we say so rather than guess.
Trademarks and logos belong to their respective owners; images are used only to identify the products. AirGreen sells and installs these products. This page is not produced, sponsored or approved by the manufacturers.
Does a value look wrong? Write to us at sales@airgreen.ca.
Related questions
From reading to your home.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.
- RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16
- Free on-site estimateAn advisor assesses your needs
- Quote within 24 hoursClear and detailed