See it on airgreen.caThe old article pitted Bosch against Goodman to find out which one "offered more". We rebuilt it without a verdict, with one 4-ton central heat pump from each brand, using a new-generation refrigerant and sold by AirGreen. The Bosch has an inverter compressor that changes speed; the Goodman, a single-speed scroll compressor. The page shows what each manufacturer publishes, and what that difference changes when it gets cold.
Bosch · IDS Ultra
BOVA-60MTB-M19E + BIVA-48MCB-M19X · AHRI 214825961
See it on airgreen.ca
Goodman · GLZS4B
GLZS4BA4810 + AMST48CU1300 · AHRI 215213861
See it on airgreen.caAlphabetical order. Product cards from airgreen.ca, for identification.
AirGreen estimate for a 48,000 BTU/h house in Montréal, on Hydro-Québec Rate D, taxes included, with the same method as on all our comparison pages. The calculation needs the HSPF2 region V of the AHRI certificate, published by NEEP. It exists for the Bosch (8.5); the Goodman combination is listed neither by NEEP nor by ENERGY STAR. The amount below is therefore the Bosch's alone, with electric baseboards as the reference point.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
Each square is worth 0.25 kWh of heat; electric baseboards would give 4 for the same kWh.
Bosch: COP at the rated point of the AHRI certificate, published by NEEP. Goodman: COP from the heating table of sheet SS-GLZS4B-R32 (GLZS4BA4810 + AMST48CU1300, 70 °F indoors); with a single speed, it is always the full-capacity one. Each COP goes with a different amount of heat: at 17 °F, 48,500 BTU/h on one side, 27,800 on the other.
Pick a temperature. The yellow marker is the heat a house whose loss reaches 48,000 BTU/h at −23.1 °C would need. The bars show what each manufacturer publishes at that temperature. Below, a one-hour diagram: when the need is under what the machine can deliver at its lowest, it stops and restarts; when it is between its minimum and its maximum, an inverter compressor can adjust its speed.
Marker, 48,000 BTU/h house: 30,715 BTU/h
One-hour diagram: simple calculation, need ÷ published capacity. The real number of cycles per hour depends on the thermostat, the ducts and the house; the three cycles drawn are only an illustration. Bosch: AHRI certificate 214825961 published by NEEP, and at −20 °C the table of Bosch sheet BTC 762008303 A. Goodman: heating table of sheet SS-GLZS4B-R32.
At −15 °C, both have a value at the same temperature: 48,500 BTU/h certified for the Bosch, 20,520 BTU/h in the Goodman table. Lower down, the Goodman table stops at −17.8 °C (0 °F). The Bosch has a value from its own table at −20 °C and a certified point at −25 °C, its stated heating limit.
At −20 °C, the Bosch value comes from its specification sheet (1,550 CFM, 70 °F indoors), not from the certificate: read it as a manufacturer value. For the Goodman, every temperature below −17.8 °C is colder than its last published point; the table repeats that point, with its temperature, and the hatched area flags it.
Each sheet has the same lines in the same order, from the certificate published by NEEP for the Bosch and each manufacturer's specification sheet. A line marked "not stated" means the document consulted does not mention it, not that the feature is missing.
The Bosch sheet gives the noise at its lowest speed and at full load. The Goodman sheet gives a single value, that of a compressor with only one speed.
How to read these numbers. dB(A) measures a noise level; the lower the number, the quieter. Each dot is a value published by the manufacturer. An inverter compressor at low speed makes less noise than at full load; a single-speed compressor always runs at the same speed when it is on.
Why this is not a ranking. The two sheets do not describe their measurement method the same way (not comparable). To the ear, distance, the walls that bounce the sound back and where the unit sits matter as much as the number. The Bosch values are those of the BOVA19-60 outdoor unit, the same for the 4- and 5-ton systems.
Two sheets, two ways of measuring: each figure stands on its own, not as a ranking.
The Bosch unit takes 29 1/8 in per side on the ground and rises to 43 5/16 in; the Goodman takes 35 1/2 in per side for 36 1/2 in of height. To-scale drawings from the dimensions published by each manufacturer.
To-scale diagram, both units set against the wall (grey line). The distances to keep around each unit are in its installation manual and are not drawn here.
Bosch: 150 ft at most, 50 ft height difference at most, factory charge for 15 ft of 3/8 in liquid line. Goodman: the factory charge covers 15 ft; beyond that, the adjustment follows its installation instructions, and sheet SS-GLZS4B-R32 sets no maximum length. The real length is measured on site.
The page compares units of the same size using a new-generation (A2L) refrigerant, sold by AirGreen. At Goodman, the R-32 central systems in our catalogue are the GLZS4B and GLZS4M series. Another of our pages already compares a Bosch IDS Light and a Goodman GLZS4M at 3 tons; this one takes the other pair, at 4 tons, with the IDS Ultra, the Bosch designed for the cold.
A single-speed compressor always delivers the same heat when it runs; to follow a smaller need, it stops and restarts. An inverter compressor changes speed: the Bosch sheet states a range of 33 to 187%, and the certificate gives a minimum and a maximum capacity at each temperature. When the need drops below its minimum, it too stops and restarts. The "One hour of heating" section shows both situations, temperature by temperature.
The two figures do not describe the same amount of heat. At −8.3 °C, the Goodman delivers 27,800 BTU/h with a COP of 2.70 according to its table; the Bosch is certified at 48,500 BTU/h with a COP of 2.1. Delivering more heat takes more electricity per unit of heat. Always compare a COP with the capacity that goes with it.
The calculation uses the HSPF2 region V of the AHRI certificate, published by NEEP. The GLZS4BA4810 + AMST48CU1300 combination (certificate 215213861) is listed neither by NEEP nor by ENERGY STAR, and the Goodman sheet only publishes series maximums, without region V. Rather than a fragile estimate, the page shows both COPs at three temperatures.
They were removed. No document allows what was described there to be checked, and grant amounts change from year to year. The page sticks to the certificates and the manufacturers' sheets.
This page does not say so. The criteria and amounts of Hydro-Québec's LogisVert program change; eligibility is checked in the official list, with the unit's AHRI number, at the time of the application.
The free assessment visit is used to measure your house's heat loss, the space outside and the line set length; the written quote follows.
Data checked November 16, 2026. Certified values: the Bosch AHRI certificate published by NEEP. Declared values: the Bosch and Goodman sheets cited above. Cost: AirGreen estimate, method v1.1, not a promise.
Bosch, IDS Ultra, Goodman and the other brands mentioned belong to their owners. Logos and images are used only to identify the products. AirGreen is a retailer; this page is not produced, sponsored or endorsed by Bosch or Goodman.
Images: product cards from airgreen.ca, for identification. Units drawn to scale: diagram.
This article, published in June 2025, was rewritten on November 16, 2026: it now compares published values, with no verdict and no job-site results.
Does a figure look wrong to you? Write to us at sales@airgreen.ca.