Head to head · Central heat pumps

Bosch IDS Ultra and Goodman GLZS4B: two 4-ton central heat pumps, figure by figure

10 min
Comparison · Central heat pump · 4 tons

Bosch IDS Ultra and Goodman GLZS4B: two 48,000 BTU/h central systems, two ways of following the cold

The old article pitted Bosch against Goodman to find out which one "offered more". We rebuilt it without a verdict, with one 4-ton central heat pump from each brand, using a new-generation refrigerant and sold by AirGreen. The Bosch has an inverter compressor that changes speed; the Goodman, a single-speed scroll compressor. The page shows what each manufacturer publishes, and what that difference changes when it gets cold.

Nominal size 48,000 BTU/h for both Refrigerant R-454B and R-32 Compressor inverter and single speed Coldest published point −25 °C and −17.8 °C
Outdoor unit of the Bosch IDS Ultra 4-ton central heat pump, AirGreen product card Bosch · IDS Ultra

IDS Ultra R-454B · 4 tons

BOVA-60MTB-M19E + BIVA-48MCB-M19X · AHRI 214825961

See it on airgreen.ca
Outdoor unit of the Goodman GLZS4B central heat pump, AirGreen product card Goodman · GLZS4B

GLZS4B R-32 · 4 tons

GLZS4BA4810 + AMST48CU1300 · AHRI 215213861

See it on airgreen.ca

Alphabetical order. Product cards from airgreen.ca, for identification.

Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for a 48,000 BTU/h house in Montréal, on Hydro-Québec Rate D, taxes included, with the same method as on all our comparison pages. The calculation needs the HSPF2 region V of the AHRI certificate, published by NEEP. It exists for the Bosch (8.5); the Goodman combination is listed neither by NEEP nor by ENERGY STAR. The amount below is therefore the Bosch's alone, with electric baseboards as the reference point.

How this amount is calculated
  1. Heat needed over the winter. A house whose heat loss reaches 48,000 BTU/h (0 kW) at −23.1 °C, Montréal's design temperature: 0 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 0 kWh of heat for heating 24 hours a day, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day ("Heating" slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 region V, the value of the AHRI certificate published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 48,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the SEER2 seasonal efficiency of the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes nominal capacity all day: a maximum, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065 ¢ per kWh up to 40 kWh a day, 11.142 ¢ above; the average price, 9.104 ¢, is the one Hydro-Québec's calculators use. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Heat delivered per 1 kWh of electricity, for both

Each square is worth 0.25 kWh of heat; electric baseboards would give 4 for the same kWh.

Bosch: COP at the rated point of the AHRI certificate, published by NEEP. Goodman: COP from the heating table of sheet SS-GLZS4B-R32 (GLZS4BA4810 + AMST48CU1300, 70 °F indoors); with a single speed, it is always the full-capacity one. Each COP goes with a different amount of heat: at 17 °F, 48,500 BTU/h on one side, 27,800 on the other.

One hour of heating

Slow down or stop: what each compressor does facing the same need

Pick a temperature. The yellow marker is the heat a house whose loss reaches 48,000 BTU/h at −23.1 °C would need. The bars show what each manufacturer publishes at that temperature. Below, a one-hour diagram: when the need is under what the machine can deliver at its lowest, it stops and restarts; when it is between its minimum and its maximum, an inverter compressor can adjust its speed.

−8.3 °C17 °F

Marker, 48,000 BTU/h house: 30,715 BTU/h

Certified range or published valueRange between two published valuesLast published value, at a milder temperatureNeed marker

One-hour diagram: simple calculation, need ÷ published capacity. The real number of cycles per hour depends on the thermostat, the ducts and the house; the three cycles drawn are only an illustration. Bosch: AHRI certificate 214825961 published by NEEP, and at −20 °C the table of Bosch sheet BTC 762008303 A. Goodman: heating table of sheet SS-GLZS4B-R32.

Deep cold

Below −15 °C: every published value, with its source

At −15 °C, both have a value at the same temperature: 48,500 BTU/h certified for the Bosch, 20,520 BTU/h in the Goodman table. Lower down, the Goodman table stops at −17.8 °C (0 °F). The Bosch has a value from its own table at −20 °C and a certified point at −25 °C, its stated heating limit.

At −20 °C, the Bosch value comes from its specification sheet (1,550 CFM, 70 °F indoors), not from the certificate: read it as a manufacturer value. For the Goodman, every temperature below −17.8 °C is colder than its last published point; the table repeats that point, with its temperature, and the hatched area flags it.

Each machine's sheet

The same lines for both

Each sheet has the same lines in the same order, from the certificate published by NEEP for the Bosch and each manufacturer's specification sheet. A line marked "not stated" means the document consulted does not mention it, not that the feature is missing.

Sound

At low speed or full speed: the decibels published for each outdoor unit

Outdoor unit, outside

The Bosch sheet gives the noise at its lowest speed and at full load. The Goodman sheet gives a single value, that of a compressor with only one speed.

dB

How to read these numbers. dB(A) measures a noise level; the lower the number, the quieter. Each dot is a value published by the manufacturer. An inverter compressor at low speed makes less noise than at full load; a single-speed compressor always runs at the same speed when it is on.

Why this is not a ranking. The two sheets do not describe their measurement method the same way (not comparable). To the ear, distance, the walls that bounce the sound back and where the unit sits matter as much as the number. The Bosch values are those of the BOVA19-60 outdoor unit, the same for the 4- and 5-ton systems.

Two sheets, two ways of measuring: each figure stands on its own, not as a ranking.

Installation

Outside: one unit taller and narrower, the other wider and lower

The Bosch unit takes 29 1/8 in per side on the ground and rises to 43 5/16 in; the Goodman takes 35 1/2 in per side for 36 1/2 in of height. To-scale drawings from the dimensions published by each manufacturer.

Bosch · BOVA-60MTB-M19E

Goodman · GLZS4BA4810

Top view: ground space taken

To-scale diagram, both units set against the wall (grey line). The distances to keep around each unit are in its installation manual and are not drawn here.

40 ft

Bosch: 150 ft at most, 50 ft height difference at most, factory charge for 15 ft of 3/8 in liquid line. Goodman: the factory charge covers 15 ft; beyond that, the adjustment follows its installation instructions, and sheet SS-GLZS4B-R32 sets no maximum length. The real length is measured on site.

Bosch · BOVA-60MTB-M19E

R-454B
  • Class A2L (ASHRAE 34), mildly flammable; GWP 466 (IPCC, 4th report).
  • Factory charge: 10 lb 8 oz, for 15 ft, per the Bosch sheet.
  • Lines: liquid 3/8 in, suction 7/8 in.

Goodman · GLZS4BA4810

R-32
  • Class A2L (ASHRAE 34), mildly flammable; GWP 675 (IPCC, 4th report).
  • Factory charge: 174 oz, for 15 ft, per the Goodman sheet.
  • Lines: liquid 3/8 in, suction 1 1/8 in (7/8 in connection on the unit; adapter supplied by the installer, per the sheet).
Questions

What people ask us about Bosch and Goodman

Why the IDS Ultra and the GLZS4B, and not the IDS Premium and the GSZV9 from the old article?

The page compares units of the same size using a new-generation (A2L) refrigerant, sold by AirGreen. At Goodman, the R-32 central systems in our catalogue are the GLZS4B and GLZS4M series. Another of our pages already compares a Bosch IDS Light and a Goodman GLZS4M at 3 tons; this one takes the other pair, at 4 tons, with the IDS Ultra, the Bosch designed for the cold.

Single speed or inverter: what does it change in practice?

A single-speed compressor always delivers the same heat when it runs; to follow a smaller need, it stops and restarts. An inverter compressor changes speed: the Bosch sheet states a range of 33 to 187%, and the certificate gives a minimum and a maximum capacity at each temperature. When the need drops below its minimum, it too stops and restarts. The "One hour of heating" section shows both situations, temperature by temperature.

At 17 °F, the Goodman's COP is higher than the Bosch's. How is that possible?

The two figures do not describe the same amount of heat. At −8.3 °C, the Goodman delivers 27,800 BTU/h with a COP of 2.70 according to its table; the Bosch is certified at 48,500 BTU/h with a COP of 2.1. Delivering more heat takes more electricity per unit of heat. Always compare a COP with the capacity that goes with it.

Why is there no dollar cost for the Goodman?

The calculation uses the HSPF2 region V of the AHRI certificate, published by NEEP. The GLZS4BA4810 + AMST48CU1300 combination (certificate 215213861) is listed neither by NEEP nor by ENERGY STAR, and the Goodman sheet only publishes series maximums, without region V. Rather than a fragile estimate, the page shows both COPs at three temperatures.

Where are the projects in Laval, Blainville, Saint-Hubert and Repentigny, and the grant amounts?

They were removed. No document allows what was described there to be checked, and grant amounts change from year to year. The page sticks to the certificates and the manufacturers' sheets.

Are these two heat pumps eligible for LogisVert?

This page does not say so. The criteria and amounts of Hydro-Québec's LogisVert program change; eligibility is checked in the official list, with the unit's AHRI number, at the time of the application.

Both are on the AirGreen website.

The free assessment visit is used to measure your house's heat loss, the space outside and the line set length; the written quote follows.

Sources

Documents consulted

NEEP, listing 422773 (Bosch, BOVA-60MTB-M19E)AHRI 214825961, IDS Ultra series · consulted November 16, 2026
Bosch, "IDS Heat Pump Ultra Series Condensing Unit", product specificationsBTC 762008303 A (08.2024) · features, ranges, sound, line set, electrical, dimensions, 4-ton extended heating · consulted November 16, 2026
Goodman, "GLZS4B Energy-Efficient Standard Family R-32 Split System Heat Pump" sheetSS-GLZS4B-R32 (08/26) · features, expanded heating, cooling, dimensions · consulted November 16, 2026
ENERGY STAR, heat pump databaseSearch for certificate 215213861: no record · consulted November 16, 2026
IPCC, Fourth Assessment Report (AR4)100-year global warming potentials: R-454B 466, R-32 675
ASHRAE 34Refrigerant safety classes: R-454B and R-32, A2L
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · consulted November 16, 2026
NRCan, HOT2000 climate mapMontréal Intl: 4,167 degree-days (base 18 °C), design temperature −23.1 °C