Air-to-water or air-to-air heat pump

Home / Comparisons / Guides by equipment type

Guide · Air-to-water or air-to-air · 5-ton example

Air-to-water or air-to-air heat pump: heating water, or heating air

Both draw heat from the outdoor air. An air-to-air unit blows it into the house, through indoor units or ducts. An air-to-water unit hands it to water, which then circulates through a radiant floor, radiators or fan coils. To make the difference concrete, this guide follows two MIDEA units of similar size, sold by AirGreen, with what their documents publish.

Adjustable heating water: 25 to 65 °C COP at 7 °C, water at 35 °C: 4.50 Heating stated down to −25 °C and −30 °C
MIDEA M Thermal Arctic, air-to-water heat pump (AirGreen image)
Air-to-water exampleMIDEA

M Thermal Arctic · 16 kW

MHA-V16WD2MN8-B2 / HB-A160CMDM30GN8-B2 · manufacturer sheet (no AHRI certificate)

View the product page
MIDEA EVOX G3, air-to-air central heat pump (AirGreen image)
Air-to-air exampleMIDEA

EVOX G3 · 5 tons

MAUSE-H60B-2A / MO1HE-H60B-2A · AHRI 215471345

View the product page
Season cost

What 1 kWh of electricity delivers, depending on the water temperature

On our other pages, a season’s cost is calculated with the HSPF2 and SEER2 from the AHRI certificate. Those ratings belong to air-to-air heat pumps: the MIDEA M Thermal Arctic has none, so the same method does not apply to it. Here is what MIDEA publishes instead: the heat produced per 1 kWh of electricity, depending on the outdoor air and the water sent into the system, and what that means in dollars at one test point.

Water sent into the system (heat pump outlet)
Outdoor air temperature
Air-to-water · M Thermal Arctic
Electric baseboards1 kWh of electricity gives 1 kWh of heat
1.00

Each square = 0.1 kWh of heat obtained per 1 kWh of electricity.

100 kWh of heat, in dollars

At Hydro-Québec’s Rate D average price, 9.104¢ per kWh, taxes included; one coin = $1.

    And the air-to-air example? Its NEEP-certified COP is measured differently: indoor air at 21.1 °C, not water at a given temperature. EVOX G3 5 tons at rated output: COP 3.36 at 8.3 °C, 2.50 at −8.3 °C and 1.90 at −15 °C. Its values therefore do not fit in the same table; its season cost is calculated with the method of our comparison pages, for example MIDEA EVOX G3 and MIDEA ATOM X.
    How this amount is calculated
    1. Electricity for 100 kWh of heat. 100 ÷ COP. The COP is the one MIDEA publishes in the M Thermal Arctic brochure (HA-SA202503V4), for the 16 kW model, at the chosen air and water temperature. For electric baseboards: 100 kWh.
    2. Price. Hydro-Québec Rate D average price in effect April 1, 2026, 9.104¢ per kWh, multiplied by 1.14975 for GST and QST. The system access charge is not counted.
    3. What this calculation is not. One test point is not a season: the air and water temperatures change all winter, and electric backup may kick in. This amount helps read the COP in dollars; it does not predict a bill.

    AirGreen method, November 9, 2026. The real bill depends on the house, the insulation, the water system, the settings and the use; this amount is not a promise.

    Water or air, in the house

    One house, cut in two: water on one side, air on the other

    On the left, the air-to-water heat pump heats the water of a radiant floor and a radiator. On the right, the air-to-air heat pump pushes air through ducts. Switch to cooling: both reverse their cycle, but cold water needs a system that can distribute it.

    On a small screen, swipe the drawing sideways.

    Air-to-water · MIDEA M Thermal Arctic
    1. The outdoor unit (photo): 1,118 × 865 × 523 mm, 97 kg, single fan.
    2. The hydronic module (photo), wall-mounted: 420 × 790 × 270 mm, 40 kg; plate heat exchanger, pump, 5 L expansion tank.
    3. The refrigerant only goes as far as the module: R-32, 3/8 and 5/8 in lines.
    4. The water flows from the module to the radiant floor and the radiator: adjustable from 25 to 65 °C in heating, 5 to 25 °C in cooling.
    5. Two zones of water possible, plus domestic hot water with a tank (20 to 60 °C).
    Air-to-air · MIDEA EVOX G3 5 tons
    1. The outdoor unit (diagram): 37 1/2 × 52 1/2 × 16 3/8 in, 243 lb, per the submittal sheet.
    2. The air handler (diagram): 21 1/2 × 21 1/2 × 60 1/8 in, 188 lb.
    3. The refrigerant goes as far as the air handler coil: R-454B, 3/8 and 3/4 in lines.
    4. The air is blown into the ducts: up to 1,801 CFM at turbo speed.
    5. Electric backup of up to 25 kW can be added in the air handler as an option.

    All four units are to the same scale, that of the 1 m bar. Photos: MIDEA M Thermal Arctic units from the AirGreen product page. On the air-to-air side, the units are drawn as diagrams at their published dimensions; the EVOX G3 photo is in the card at the top. The house itself is not to scale.

    Water temperature

    Your water system decides almost everything

    Natural Resources Canada describes air-to-water as less common in Canada, and a better match for water under 45 to 50 °C: radiant floors, fan coils, low-temperature radiators. High-temperature radiators that need more than 60 °C may exceed what most residential heat pumps produce. Choose your system to see where it falls, next to the range MIDEA publishes.

    Extreme cold

    Below −15 °C: what each sheet publishes

    MIDEA’s air-to-water sheet gives a last point at −15 °C, with water at 43.3 °C. NEEP certifies the air-to-air unit at −15 °C and then at −30 °C, with indoor air at 21.1 °C. The two units do not have the same rated capacity (about 54,600 and 55,000 BTU/h according to their documents) or the same test method: read each column on its own.

    What MIDEA states below −15 °C. M Thermal Arctic (brochure HA-SA202503V4): heating range stated down to −25 °C (−13 °F), and no capacity figure below −15 °C; the brochure also states no capacity drop at −10 °C (14 °F), with no table to back it. EVOX G3 5 tons (submittal sheet MAUSE-H60B-2A / MO1HE-H60B-2A): standard heating operating range of −30 to 24 °C; NEEP certifies 37,300 BTU/h at −30 °C. The sheet’s “100% capacity at −13 °F” statement refers, according to its own note, to the 3-ton match: it is not repeated here.
    Documented features

    What MIDEA states for each, line by line

    The features come from the air-to-water brochure and the air-to-air submittal sheet. They describe what each unit can do; they do not all compare, since one heats water and the other heats air.

    Weather-compensation curves

    Air-to-water: 8 heating curves, 8 cooling curves and one custom curve; the water temperature follows the outdoor temperature.

    Air-to-air: constant airflow up to 1.0 in w.c., adaptive control.

    Domestic hot water

    Air-to-water: hot water from 20 to 60 °C with a tank; 60 °C only with the tank’s backup element; disinfection cycle and fast DHW function.

    Air-to-air: not applicable, the unit heats air.

    Heating zones

    Air-to-water: two water zones (zone 2 pump and valve).

    Air-to-air: one zone per unit, set by a thermostat.

    Electric backup heat

    Air-to-water: 3 kW element in the module, optional.

    Air-to-air: backup kit up to 25 kW, optional.

    Quiet mode

    Air-to-water: two levels; minimum outdoor-unit sound pressure of 45 dB(A).

    Air-to-air: “quiet” indoor-unit speed, 37 dB(A).

    Controls, Wi-Fi and app

    Air-to-water: multifunction wired control and app; power-input limiting.

    Air-to-air: two-way wired control with Wi-Fi (120N, X6W), remote or 24 V thermostat.

    Base pan heater

    Air-to-water: not stated by the manufacturer in the brochure.

    Air-to-air: base pan heater and crankcase heater as standard.

    Refrigerant leak detection

    Air-to-water: the refrigerant stays in the outdoor unit and the module; not stated by the manufacturer in the brochure.

    Air-to-air: R-454B refrigerant sensor in the indoor unit (series spec sheet).

    Indoor unit installation

    Air-to-water: wall-mounted module, 1 in NPT water connections.

    Air-to-air: several positions (horizontal left or right, vertical up or down).

    Sound

    How loud each one is, according to MIDEA

    The air-to-water brochure gives a sound pressure measured at 1 m; the air-to-air sheet gives levels by speed without stating the measuring distance. The numbers are placed on the same scale for reading, not for ranking.

    dB(A)

    How to read these numbers. dB(A) measures a noise level as the ear perceives it: the lower the number, the quieter the unit. Each dot is a published value.

    Why this is not a ranking. The two sheets do not measure the same way (distance, conditions, speed). Different method: not comparable.

    Outside, the outdoor unit

    Published values

    In the house, the indoor unit

    Hydronic module or air handler

    Measurements taken by the manufacturer with each document’s own method: read them as reference points, not as a ranking.

    Installation

    What each installation requires, according to MIDEA

    Air-to-water adds a water system, with its fittings, pump and expansion tank. Air-to-air adds air ducts. The table lists the published limits for each unit.

    InstallationAir-to-water · M Thermal ArcticAir-to-air · EVOX G3 5 tons
    Connection inside the houseWater system, 1 in NPT fittingsAir ducts, static pressure up to 0.8 in w.c.
    Maximum line-set lengthRefrigerant, between the two units98 ft246 ft
    Minimum line-set length6.5 ftNot published by the manufacturer in the submittal sheet.
    Precharged lengthNot published by the manufacturer in the brochure.25 ft
    Maximum height difference65.5 ft98 ft
    Liquid – gas diameters3/8 – 5/8 in3/8 – 3/4 in
    Outdoor unit W × H × D, weight44 × 34 1/16 × 20 9/16 in, 214 lb37 1/2 × 52 1/2 × 16 3/8 in, 243 lb
    Indoor unit, weightModule 16 9/16 × 31 1/8 × 10 5/8 in, 88 lbAir handler 21 1/2 × 21 1/2 × 60 1/8 in, 188 lb
    Outdoor unit power supply208/230 V, 1 phase, 60 Hz208/230 V, 1 phase, 60 Hz; MCA 40 A, MOP 40 A
    Water or air flowWater: 0.7 to 3 m³/h (3.08 to 13.21 gal/min)Air: 1,236 to 1,801 CFM
    Stated heating / cooling range−25 to 35 °C / −5 to 43 °C−30 to 24 °C / −30 to 50 °C
    RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-454B · GWP 466 · A2L

    Sources: MIDEA brochure “NA M thermal Arctic Split Series”, HA-SA202503V4 (16 kW model); MIDEA submittal sheet MAUSE-H60B-2A / MO1HE-H60B-2A, Extreme Heat AHU series, undated; 246 ft maximum length: MIDEA EVOX Extreme Heat installation manual, rev. 5 (10/23/2025), the submittal sheet leaving the field blank. The installer always follows the installation manual and the nameplate.

    Frequently asked questions

    What people ask us about air-to-water

    Can my hot-water radiators work with an air-to-water heat pump?

    It depends on the water temperature they need in extreme cold. Natural Resources Canada warns about high-temperature radiators that need more than 60 °C. MIDEA publishes heating water adjustable up to 65 °C for the M Thermal Arctic, but its COP drops as the water gets hotter: 4.50 at 35 °C and 2.90 at 55 °C, at 7 °C outside. Compatibility is checked on site, room by room.

    My radiant floor is electric. Can an air-to-water unit connect to it?

    No. A floor heated by electric cables contains no water. An air-to-air heat pump can be added alongside it.

    Does an air-to-water unit cool?

    MIDEA publishes a cooling mode, with water from 5 to 25 °C. To cool the rooms, you need a system that can distribute that cold water, such as fan coils. A radiant floor is not designed to blow air.

    Can the boiler be kept as backup?

    Natural Resources Canada describes hybrid systems where the heat pump uses a backup system, such as a boiler; these systems do not run at the same time as the heat pump. The connection is designed on site with the existing system.

    Why no dollar estimate for the season?

    Our seasonal estimate, the same on all our comparison pages, relies on the HSPF2 and SEER2 from the AHRI certificates of air-to-air heat pumps. The MIDEA M Thermal Arctic is described by a COP at specific air and water temperatures. Applying the same method would be inaccurate, so the page shows what 1 kWh is worth at each published point.

    Is an air-to-water heat pump eligible for grants?

    Eligibility depends on the program, its official list on the purchase date and the exact unit. This page promises no amount.

    Specs

    The published values, unit by unit

    The air-to-water unit is described by the manufacturer’s brochure; the air-to-air unit by its AHRI certificate, published by NEEP. The test conditions differ: nothing is highlighted.

    Published valueAir-to-water · M Thermal ArcticAir-to-air · EVOX G3 5 tons
    Heating, under each document’s conditions
    Rated heating capacityDifferent conditions, not directly comparable54,589 BTU/h (16 kW), air 7 °C, water 35 °C55,000 BTU/h, air 8.3 °C, indoor air 21.1 °C
    COP at rated capacityDifferent conditions4.50 (air 7 °C, water 35 °C)3.36 (air 8.3 °C)
    Capacity at −15 °CDifferent conditions33,780 BTU/h, water 43.3 °C54,000 BTU/h
    COP at −15 °CDifferent conditions2.061.90
    HSPF2 Region IV / VNot applicable: a rating for air-to-air heat pumps9.5 / 7.7
    Cooling
    Cooling capacity47,765 BTU/h, air 35 °C, water 7 °C54,000 BTU/h at 35 °C
    Published cooling efficiencyEER 8.37 (air 35 °C, water 7 °C)SEER2 17.5 · EER2 12
    Certifications and refrigerant
    ENERGY STAR / cold climate (NEEP)Not listed by NEEPYes / Yes
    AHRI certificate · NEEP recordNone: manufacturer sheet215471345 · 387394
    RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-454B · GWP 466 · A2L

    Nothing is highlighted in this table: the two units are not measured under the same conditions. On our other pages, “higher” marks the higher value of the same measurement under the same conditions; it is never a recommendation.

    Both are on the AirGreen website.

    To choose for your home, talk to our team: bring the type of system you have (water, ducts or baseboards), the water temperature it needs and the area to heat.

    Sources and documents

    Where every number comes from