Home / Comparisons / 12,000 BTU wall-mounted heat pumps
HITACHI airHome 800 and the MIDEA35, one published point at a time
Two 12,000 BTU wall-mounted units, both ENERGY STAR cold climate certified and offered by AirGreen, one on R-32, the other on R-454B. Their certificates are read at the same four heating temperatures. Between −15 and −30 °C, only one of the two manufacturers publishes figures. This page shows, temperature by temperature, who documents what.
airHome 800 12,000 BTU
RAK-XJ12PHAA / RAC-XJ12WHAA · AHRI 215911631
See the product page
MIDEA35 12,000 BTU
MSESU-H12B-2A / MO1SS-H12B-2A · AHRI 215471387
See the product pageHeating: the temperatures at which a figure is published. See each point
What the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Here, both certified seasonal ratings of the MIDEA35 are the higher ones, a Region V HSPF2 of 9.5 against 8.7 and a SEER2 of 29.4 against 25.0: the calculation reflects it in winter and in summer. Electric baseboards serve as the reference point.
How this amount is calculated
- Heat to deliver over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
- Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.
AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
Six temperatures, and who publishes a figure at each
The slider stops only at temperatures where at least one of the two manufacturers publishes a heating capacity. At each stop, a solid light means a figure exists for that unit; a dashed light means there is none. Nothing is calculated between two stops.
Maximum heating capacity at each temperature. NEEP certified: value from the AHRI certificate, with its COP. Per the manufacturer: the “Max. Heating Capacity” line of the HITACHI airHome 800 brochure (December 2024), with no power or COP. Bars on the same scale, from 0 to 20,000 BTU/h.
Below −15 °C: each published figure, at its exact temperature
NEEP certifies both units at −15 °C and at −30 °C, at the same temperatures. In between, HITACHI publishes in its brochure a maximum capacity at −20 °C and at −25 °C; MIDEA publishes no capacity figure. At those two temperatures, the table gives for the MIDEA35 the two certified values on either side.
The points are not joined: the airHome 800 is higher at −15 °C, the MIDEA35 at −30 °C, and the two lines would cross at a temperature no source gives.
Two brochures, six headings: who documents what
HITACHI airHome 800 brochure (Johnson Controls Hitachi Air Conditioning, December 2024), airHome 800 technical catalogue and installation manual IA2693:A; MIDEA Canada wall-mounted systems brochure (2025-08-20), whose feature table is shared by the MIDEA35, 28 and 25 series. Base pan heater: data declared by each manufacturer to NEEP.
airHome 800: heating advertised down to −30 °C; adaptive defrost; 150 W base pan heater; optional snow protection accessory.
MIDEA35: heating advertised down to −30 °C. 150 W base pan heater: it switches on for 5 minutes after 25 minutes of heating, if the outdoor temperature stays below 3 °C for 30 seconds.
airHome 800: down to −20 °C outside.
MIDEA35: down to −30 °C outside.
airHome 800: Smart Eco, SleepSense, silent mode, motion sensor.
MIDEA35: Turbo, ECO and “Gear”, silent mode, sleep mode, 8 °C hold in heating, smart presence sensor.
airHome 800: Wi-Fi through an interface concealed in the unit, airCloud Go app; wireless remote RC-BGH1FA0N included; airPoint Room H700 wall controller and third-party thermostat through a module, both optional.
MIDEA35: Wi-Fi with the SmartHome app; optional voice control, 7-day programmable wired controller and 24 V interface; dry contact.
airHome 800: five published speeds, from “Super Low” to “High”.
MIDEA35: fan adjustable from 1 to 100%; “Follow Me”; vertical and horizontal swing.
airHome 800: PM2.5 activated carbon filter, stainless steel pre-filter, FrostWash 3.0, Mold Guard 2.0.
MIDEA35: automatic cleaning; the fan wheel comes out for deep cleaning.
A feature missing from a brochure is not necessarily missing from the unit: this page only repeats what each document writes.
Five published speeds from HITACHI, four from MIDEA
HITACHI publishes five speeds for the airHome 800, from “Super Low” to “High”. MIDEA publishes four speeds for the MIDEA35, from “Silent” to “High”; the Turbo speed has no figure in the brochure. Both give a level in dB(A).
How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is a fan speed published by the manufacturer, from the slowest to the fastest.
Why this is not a ranking. HITACHI measures a sound pressure in an anechoic chamber, 1 m from the air outlet grille. MIDEA publishes neither the distance nor the measurement conditions in the brochure consulted. A gap of a few dB(A) can come from the method as much as from the unit.
Indoor unit, in the room
Cooling, every published speed
Outdoor unit, outside
Highest published speed
Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.
Sources: HITACHI airHome 800 brochure (December 2024) and airHome 800 technical catalogue (North America), which describes the measurement conditions; MIDEA Canada wall-mounted systems brochure (2025-08-20), p. 10. The MIDEA submittal for the EP High Tier series states 42 dB(A) for the indoor unit’s “High” and “Turbo” speeds.
41.33 or 37.99 in on the wall, 100 or 82 ft of piping
Is your wall wide enough?


Width of the unit only, to scale. The side clearances required by the installation manual are added; the installer confirms them on site.
Piping length and refrigerant
Coloured band: length covered by the factory charge. Dark line: published maximum. Additions per each manufacturer: 0.11 oz/ft of R-32 after 49 ft (HITACHI installation manual IA2693:A) and 0.16 oz/ft of R-454B after 24.6 ft (MIDEA).
Indoor units to scale


Width × height × depth per the manufacturers. The airHome 800 is 3.34 in wider. HITACHI prints a height of 11.73 in next to 294 mm; 294 mm gives 11.57 in, the value used here. Photos scaled by width.
| Installation | airHome 800 | MIDEA35 |
|---|---|---|
| Maximum piping length | 100 ft | 82 ft |
| Precharged length | 49 ftInstallation manual IA2693:A: no addition up to 15 m, then 0.11 oz/ft. | 24.6 ft0.16 oz/ft added beyond. |
| Maximum height difference | 65.6 ft | 49.2 ft |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 33.46 × 25.59 × 11.73 in, 91.0 lb | 35.04 × 26.50 × 13.46 in, 99.65 lb |
| Indoor unit, weight | 30.07 lb | 28.22 lb |
| Electrical protectionPer the manufacturer | MOP 25 A (MCA 14 A) | Max. fuse 20 A (MCA 16 A) |
| Outdoor unit clearances | From 100 to 700 mm depending on the side, with at least three sides open to the airInstallation manual IA2693:A, figure; the side for each value is read on the figure. | No figure in the brochure or in the submittalThe installer follows the installation manual supplied with the unit. |
| Outdoor unit base pan heaterDeclared by the manufacturer to NEEP | Yes, 150 W | Yes, 150 WBelow 3 °C for 30 s, after 25 min of heating, for 5 min. |
| Refrigerant and factory charge | R-32, 2.65 lb (1.2 kg) | R-454B, 44.09 oz (1.25 kg) |
| Dehumidification | 3.0 L/h | 0.5 L/hEP High Tier submittal; the brochure does not print it. |
| Rated heating / cooling range | −30 to 24 °C / −20 to 46 °CBrochure table; its cover says +22 °C and +45 °C. | −30 to 24 °C / −30 to 50 °C |
Eight questions about the airHome 800 and the MIDEA35
Which one heats more on a January night?
At −15 °C, NEEP certifies 15,200 BTU/h maximum for the airHome 800 and 13,500 BTU/h for the MIDEA35. At −8.3 °C: 16,800 and 14,600 BTU/h. These are temperatures at which both are tested under the same conditions.
And at −30 °C?
Both are certified at −30 °C, and the order reverses: 7,500 BTU/h maximum for the MIDEA35, with a COP of 1.29, and 6,000 BTU/h for the airHome 800, with a COP of 1.06. No source says at exactly what temperature the two capacities meet between −15 and −30 °C.
Why does the MIDEA35 have no figure at −20 and −25 °C?
MIDEA does not publish a capacity at those temperatures, in its brochure or in its submittal. HITACHI publishes some in its brochure: 13,500 BTU/h at −20 °C and 10,500 BTU/h at −25 °C, manufacturer values, not certified. For the MIDEA35, this page shows the two neighbouring certified points, 13,500 BTU/h at −15 °C and 7,500 BTU/h at −30 °C, without calculating anything in between.
Why is the airHome 800 certified at 12,500 BTU/h in cooling?
That is the rated capacity on its AHRI certificate 215911631. The name “12,000 BTU” refers to the size; the certified capacity is the one from the test. The estimated cost at the top of the page compares the two units for the same 12,000 BTU/h zone.
One unit on R-32, the other on R-454B: what does that change?
Both refrigerants are class A2L under ASHRAE Standard 34, and each unit runs on the one its manufacturer chose. At installation, the factory charge of the airHome 800 covers 49 ft of piping, that of the MIDEA35, 24.6 ft; beyond that, the installer adds 0.11 oz/ft of R-32 or 0.16 oz/ft of R-454B. The R-32 or R-454B guide explains the two fluids.
Why is the HSPF2 of the MIDEA35 not the one in its brochure?
The MIDEA Canada brochure of August 20, 2025 gives 14.5 in Region IV and 10.0 in Region V for the MIDEA35, with a COP of 3.60 at −15 °C. Its AHRI certificate, 215471387, carries 12.7, 9.5 and 2.00; NEEP and the ENERGY STAR directory repeat those three figures. This page keeps to the certificate, including in the estimated cost.
Which one is quieter?
The manufacturers publish 30 to 48 dB(A) for the indoor unit of the airHome 800 and 19 to 41.5 dB(A) for that of the MIDEA35. HITACHI states its method, 1 m from the air outlet grille in an anechoic chamber; the MIDEA brochure does not give its conditions. These figures situate each unit; they do not allow a ranking.
Are they eligible for grants?
Eligibility depends on the official list in force on the date of purchase. This page promises no amount; the current list is checked at the time of the quote.
The two certificates, line by line
| Certified value | airHome 800 | MIDEA35 |
|---|---|---|
| Cooling | ||
| Rated capacity at 35 °C | 12,500 BTU/h | 12,000 BTU/h |
| SEER2 | 25.0 | 29.4 |
| EER2 | 14.5 | 14.2 |
| Heating, same conditions | ||
| HSPF2 Region IV | 11.5 | 12.7 |
| HSPF2 Region V | 8.7 | 9.5 |
| 8.3 °C: min. / rated / max.BTU/h | 4,700 / 12,500 / 19,000 | 4,000 / 12,000 / 17,200 |
| 8.3 °C: COP min. / rated / max. | 2.81 / 3.13 / 3.26 | 5.86 / 3.59 / 3.17 |
| −8.3 °C: min. / rated / max.BTU/h | 4,500 / 11,000 / 16,800 | 1,600 / 11,000 / 14,600 |
| −8.3 °C: COP min. / rated / max. | 1.78 / 2.93 / 2.15 | 1.88 / 2.41 / 2.26 |
| −15 °C: min. / rated / max.BTU/h | 3,500 / 10,500 / 15,200 | 900 / 13,500 / 13,500 |
| −15 °C: COP min. / rated / max. | 1.39 / 2.09 / 2.12 | 1.15 / 2.00 / 2.00 |
| Coldest point — same temperature for both, not highlighted | ||
| Test temperature | −30 °C (−22 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 1,760 / 6,000 BTU/h | 4,100 / 7,500 BTU/h |
| COP at maximum capacity | 1.06 | 1.29 |
| Power at maximum capacity | 1.66 kW | 1.70 kW |
| Listings and refrigerant | ||
| ENERGY STAR / cold climate (NEEP) | Yes / Yes | Yes / Yes |
| ENERGY STAR directory, markets listed | United States | United States, Canada |
| AHRI certificate · NEEP record | 215911631 · 484774 | 215471387 · 387352 |
| RefrigerantGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2L | R-454B · GWP 466 · A2L |
higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COPs by point are not highlighted: the order changes depending on the point read.
Both are on the AirGreen website.
A question about either one, or about the wall space needed? Our team will answer: have the room dimensions and the free wall width at hand.
Where each figure comes from
Data verified November 9, 2026. Performance: AHRI certificates and the NEEP database. Dimensions, sound, piping, refrigerant charge and features: according to the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. HITACHI, airHome, MIDEA and MIDEA35 are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer for both brands; this page is not produced, sponsored or endorsed by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong to you? Write to us: any reported value is checked again.