LG DUALCOOL R32 and LG ARTCOOL DELUXE R32, 12,000 BTU

Home / Comparisons / 12,000 BTU wall-mounted heat pumps

Comparison · wall-mounted heat pump · 12,000 BTU

LG DUALCOOL R32 and LG ARTCOOL DELUXE R32: two certificates, degree by degree

Two 12,000 BTU LG wall-mounted heat pumps on R-32, two AHRI certificates. The NEEP record for the DUALCOOL R32 stops at −20 °C; the one for the ARTCOOL DELUXE R32 goes down to −35 °C. This page follows both certificates as the temperature drops and shows, at each published point, what each one states.

SEER222.5·25.5
HSPF2 Region IV10.5·11.2
Max. at −15 °C, certified (BTU/h)10,000·14,700
ENERGY STAR cold climate designationYes·Yes
LG DUALCOOL R32 12,000 BTU (AirGreen image) LG

DUALCOOL R32 · 12,000 BTU

KNUAB121A / KUSAB121A · AHRI 215413007

−20 °CLast certified point8,010 BTU/h maximum, COP 1.79 (NEEP)

Same AHRI and NEEP certified values as the 12,000 BTU ARTCOOL MIRROR R32 (AHRI 215413008), which uses the same KUSAB121A outdoor unit.

View the product page
LG ARTCOOL DELUXE R32 12,000 BTU (AirGreen image) LG

ARTCOOL DELUXE R32 · 12,000 BTU

KNSAL121A / KUSAL121A · AHRI 216368960

−35 °CLast certified point9,100 BTU/h maximum, COP 1.33 (NEEP)

No other NEEP record carries the KUSAL121A outdoor unit (search of Nov. 9, 2026).

View the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h (3.52 kW) at −23.1 °C, Montréal’s design temperature: 3.52 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 8,558 kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: a simplification that does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ Region V HSPF2, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

From standard to extreme cold

Two thermometers, two last certified points

Each column fills down to the coldest point NEEP publishes for the unit. Move the slider or start the descent: at each temperature, you see the published value, the range between the two neighbouring values, or the last known point.

DUALCOOL R32 LG
ARTCOOL DELUXE R32 LG

Bars: published maximum heating capacity, on the same scale from 0 to 20,000 BTU/h. Hatched bar: range between two published values. Dotted outline: last published point, at its own temperature.

15 °C separate the two last certified points. The NEEP record for the DUALCOOL R32 stops at −20 °C, with 8,010 BTU/h maximum. The one for the ARTCOOL DELUXE R32 still has a point at −35 °C, with 9,100 BTU/h. These two values were measured at different temperatures: they do not compare with each other.

The two certificates side by side

What is identical, what changes

Both units carry the ENERGY STAR cold climate designation. So the difference is not in the designation: it is in the values each certificate and each brochure publishes.

Identical on both

  • RefrigerantR-32
  • Rated cooling capacity, certified12,000 BTU/h
  • ENERGY STAR cold climate designation (NEEP)Yes
  • Base pan heater, per the NEEP record90 W
  • Liquid – gas piping diameters1/4 – 3/8 in
  • Length without added refrigerant41 ft
  • Compressor type, per LGTwin rotary

Different: DUALCOOL R32, then ARTCOOL DELUXE R32

Last NEEP certified point−20 °C−35 °C
Certified maximum capacity at −15 °C10,00014,700 BTU/h
Heating range stated by LG (wet bulb)−20 °C−35 °C
HSPF2 Region V8.08.4
SEER222.525.5
Outdoor unit weight68.8 lb99.2 lb
Maximum piping length82 ft65.6 ft
Maximum electrical protection (MOCP)15 A20 A

Certified values: NEEP, records 389313 and 383065. Declared values: LG brochures of the 04_25 series. The detail, with the conditions of each measurement, is in the sections that follow.

Extreme cold

Below −15 °C: every published value, down to −35 °C

Below −15 °C, NEEP certifies one point for each unit: −20 °C for the DUALCOOL R32, −35 °C for the ARTCOOL DELUXE R32. The 2025 LG brochure for the ARTCOOL DELUXE adds the maximum capacity at −18, −20 and −25 °C. Between two published values, we show the range; nothing is calculated.

At −15 °C, both values come from NEEP. At −20 °C, the DUALCOOL R32 value is certified and repeated in its brochure; the ARTCOOL DELUXE R32 value comes from its LG brochure: same temperature, but a certified value on one side and a manufacturer value on the other. Below −20 °C, only the ARTCOOL DELUXE R32 has published values.

What LG states as a percentage of rated capacity

The LG brochures express maximum heating capacity relative to each model’s rated capacity: 13,600 BTU/h for the DUALCOOL R32, 13,000 BTU/h for the ARTCOOL DELUXE R32. The bases differ; so the percentages are read model by model. The line marks 100%.

DUALCOOL R32 brochure PO_LG_R32_High_Efficiency_04_25
91%at −8 °C · 12,400 BTU/h
74%at −15 °C · 10,000 BTU/h
59%at −20 °C · 8,010 BTU/h
ARTCOOL DELUXE R32 brochure PO_LG_R32_ArtCool_Mirror_Deluxe_04_25
113%at −15 °C · 14,700 BTU/h
108%at −20 °C · 14,000 BTU/h
100%at −25 °C · 13,000 BTU/h
Features

What LG writes for each model, feature by feature

The features come from two kinds of LG documents: the Canadian brochure for each series and the LG Electronics U.S.A. submittal sheet for the same model number. When neither mentions a feature, we say so: that does not mean the feature does not exist.

Heating in extreme cold
DUALCOOL R32: stated heating range from −20 to 18 °C (wet bulb).ARTCOOL DELUXE R32: “Extreme Cold Performance”, 100% of heating capacity at −25 °C and heating down to −35 °C, per LG.

An operating range says how far down the unit is designed to heat; the capacity at each temperature is in the Extreme cold section.

Base pan heater
DUALCOOL R32: “built-in heating element for the condensate pan”, under “reliable defrost” (French brochure).ARTCOOL DELUXE R32: “Built-in Base Pan Heater”, per the submittal sheet.

Both NEEP records list a 90 W element, on at 0 °C and below in heating mode.

Wi-Fi app
DUALCOOL R32: “Built-in Wi-Fi via ThinQ app”, per the submittal sheet.ARTCOOL DELUXE R32: “Built-in Wi-Fi via Smart ThinQ app”, per the submittal sheet.

The Canadian brochures do not mention Wi-Fi; the submittal sheets do.

Presence and humidity sensing
DUALCOOL R32: not stated in the documents consulted.ARTCOOL DELUXE R32: “Built-in Occupancy Sensor” in the brochure; “Human Detection” and “Humidity Sensor / Control” in the submittal sheet.

LG describes a presence sensor built into the indoor unit, which adjusts the airflow when the room is empty.

Maintenance and cleaning
DUALCOOL R32: “Self-cleaning indoor coil”, “3M Micro Filter”, per the submittal sheet.ARTCOOL DELUXE R32: Auto Clean+; Freeze Clean (with ThinQ only), per the brochure.

Each document names maintenance in its own words.

Air delivery and louver
DUALCOOL R32: “4-Way auto swing”, “Jet Cool/Jet Heat”, per the submittal sheet; maximum airflow of 459 CFM in cooling.ARTCOOL DELUXE R32: “Efficient Airflow”, dual vane, upward in cooling and downward in heating; “Jet Cool / Jet Heat”, per the submittal sheet; maximum airflow of 494 CFM in cooling.

Airflow rates published by LG for each model, maximum speed.

Refrigerant leak detection
DUALCOOL R32: “IDU R32 leak detection sensor”, per the submittal sheet.ARTCOOL DELUXE R32: not stated in the documents consulted.

Wording repeated as LG writes it.

Timer and automatic restart
DUALCOOL R32: “24-Hour on/off timer”, “Auto Restart”, “Auto Changeover”, per the submittal sheet.ARTCOOL DELUXE R32: “Auto Restart / Auto Changeover”, per the submittal sheet; the timer is not named there.

Control features named in the submittal sheets.

Cooling in cold weather
DUALCOOL R32: down to −10 °C; down to −18 °C with the optional wind and low-temperature protection kit.ARTCOOL DELUXE R32: down to −10 °C; down to −18 °C with the optional kit (“Low ambient cooling down to 14 °F (0 °F with Wind Baffle Kit)”, submittal sheet).

Useful for a room that needs cooling even in winter.

Documented featureDUALCOOL R32ARTCOOL DELUXE R32
Base pan heaterYes brochure 04_25; NEEP record: 90 W, on at 0 °C and below, in heating modeYes Built-in Base Pan Heater; NEEP record: 90 W, on at 0 °C and below, in heating mode
Wi-Fi appYes ThinQ, LG U.S.A. submittal sheetYes ThinQ, LG U.S.A. submittal sheet
Built-in occupancy sensorNot published by the manufacturer brochure 04_25 and submittal sheetYes Built-in Occupancy Sensor
Humidity sensorNot published by the manufacturer brochure 04_25 and submittal sheetYes Humidity Sensor / Control
Filter and automatic cleaningYes Self-cleaning indoor coil; 3M Micro FilterYes Auto Clean+
Refrigerant leak detectionYes IDU R32 leak detection sensorNot published by the manufacturer brochure 04_25 and submittal sheet
Automatic restartYes Auto Restart; 24 h timerYes Auto Restart / Auto Changeover
Published fan speeds4 459 / 388 / 318 / 194 CFM in cooling4 494 / 424 / 318 / 219 CFM in cooling
Cooling in cold weatherYes down to −10 °C; −18 °C with the optional kitYes down to −10 °C; −18 °C with the optional kit
CompressorTwin rotary brochure 04_25Twin rotary Twin-Rotary, brochure 04_25
Sound

Indoor unit sound, fan speed by fan speed

Published indoor sound pressure

Each point is a fan speed published by LG, in heating mode.

dB

How to read these figures. The lower the decibels, the quieter the unit. Each point is one published fan speed. A rise of 10 dB(A) is heard as roughly twice as loud.

Why this is not a ranking. Both sets of values come from LG brochures of the same year, with the same labels. LG does not specify the distance or the measurement room there. The gap is 1 dB(A) at the low and high speeds, and zero at the medium speed.

Measurements taken by the manufacturer using its own method, not described in the brochures: declared values, to be read as such.

Installation

Two different sizes, inside and out

The ARTCOOL DELUXE R32 is wider and deeper on the wall, and its outdoor unit weighs 30.4 lb more. The DUALCOOL R32 accepts longer piping.

The two indoor units, widths to the same scale

DUALCOOL R3232 15/16 in · 837 mm
LG DUALCOOL R32 indoor unit
32 15/16 in · 837 mm
ARTCOOL DELUXE R3235 1/4 in · 895 mm
LG ARTCOOL DELUXE R32 indoor unit
35 1/4 in · 895 mm
40 in
DUALCOOL R32

ARTCOOL DELUXE R32

Width of the unit only, per LG. The clearances around the indoor unit and the outdoor unit are given in each model’s installation manual.

The piping length between the two units

25 ft
DUALCOOL R32
ARTCOOL DELUXE R32
0 ft45 ft90 ft
precharged, up to 41 ftadd 0.16 oz of R-32 per footbeyond the published maximum length

Lengths and added refrigerant per the LG brochures: minimum 9.8 ft for both; maximum 82 ft for the DUALCOOL R32 and 65.6 ft for the ARTCOOL DELUXE R32. Diagram: the exact amount is calculated by the installer.

Installation, per the LG brochuresDUALCOOL R32ARTCOOL DELUXE R32
Maximum piping length82 ft minimum 9.8 ft65.6 ft minimum 9.8 ft
Precharged length41 ft 0.16 oz per ft beyond41 ft 0.16 oz per ft beyond
Factory R-32 precharge28.9 oz40.6 oz
Maximum height difference49.2 ft39.4 ft
Liquid – gas line diameters1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight30 5/16 × 21 15/32 × 11 11/32 in, 68.8 lb34 1/4 × 25 19/32 × 13 in, 99.2 lb
Indoor unit, weight32 15/16 × 12 1/8 × 7 7/16 in, 19.7 lb35 1/4 × 12 3/32 × 9 1/4 in, 24.3 lb
Electrical protectionMCA 12 A · MOCP 15 AMCA 15 A · MOCP 20 A
Outdoor unit sound, maximum47 dB(A) in cooling · 51 dB(A) in heating48 dB(A) in cooling · 50 dB(A) in heating
Dehumidification1.3 L/h 2.75 US pints/h per LG1.7 L/h 3.59 US pints/h per LG
Stated heating / cooling range−20 to 18 °C / −10 to 48 °C heating at wet-bulb temperature−35 to 18 °C / −10 to 48 °C heating at wet-bulb temperature; 18.3 and 47.8 °C per LG
Questions

Questions about this pair

Both have the ENERGY STAR cold climate designation: where is the difference?

In the certified points. At −15 °C, NEEP publishes 10,000 BTU/h maximum for the DUALCOOL R32 and 14,700 BTU/h for the ARTCOOL DELUXE R32. The coldest point of the first is at −20 °C (8,010 BTU/h), that of the second at −35 °C (9,100 BTU/h).

What does LG publish for the DUALCOOL R32 below −20 °C?

Nothing. Its brochure states a heating range from −20 to 18 °C, wet bulb, and its NEEP record stops at −20 °C. This page invents nothing colder: it shows the last published point, with its temperature.

Why does LG write 74% for one and 113% for the other at −15 °C?

LG relates maximum capacity to each model’s rated heating capacity: 10,000 ÷ 13,600 = 74% for the DUALCOOL R32, 14,700 ÷ 13,000 = 113% for the ARTCOOL DELUXE R32. The two bases are not the same; the values in BTU/h, however, compare at the same temperature.

Which one costs less to run?

With our method, the gap comes from the certified efficiencies: HSPF2 Region V of 8.0 and 8.4, SEER2 of 22.5 and 25.5. The “Cost by season” module shows the exact gap, in dollars, for your hours of use and the price per kWh.

Do the two units take up the same space?

No. The DUALCOOL R32 indoor unit is 32 15/16 in wide and 7 7/16 in deep; the ARTCOOL DELUXE R32 one, 35 1/4 in and 9 1/4 in. The outdoor unit weighs 68.8 lb for the first and 99.2 lb for the second, per LG.

Does the DUALCOOL R32 share its certificate with another model?

It has its own certificate, AHRI 215413007. The 12,000 BTU ARTCOOL MIRROR R32 (KNUAK121A) uses the same KUSAB121A outdoor unit, and its AHRI certificate 215413008 carries the same AHRI and NEEP certified values (NEEP records 389313 and 389312, consulted November 9, 2026). The indoor unit, however, is different.

What about the warranty?

LG publishes its terms for each model. The warranty documents come with the quote.

Certified data sheet

The AHRI certificate values, published by NEEP

Certified valueDUALCOOL R32ARTCOOL DELUXE R32
Seasonal efficiencies
SEER222.525.5
EER212.813.8
HSPF2 Region IV10.511.2
HSPF2 Region V8.08.4
Rated capacity at 35 °C (cooling)12,000 BTU/h12,000 BTU/h
Heating, min. / rated / max. capacity
Min. / rated / max. capacity at 8.3 °C1,023 / 13,600 / 19,0403,070 / 13,000 / 20,000
Min. / rated / max. capacity at −8.3 °C1,877 / 8,500 / 12,4002,627 / 8,400 / 16,820
Min. / rated / max. capacity at −15 °C1,706 / 10,000 / 10,0002,388 / 14,700 / 14,700
Min. / rated / max. COP at 8.3 °C1.50 / 3.83 / 2.834.74 / 4.10 / 2.93
Min. / rated / max. COP at −8.3 °C1.49 / 2.86 / 2.191.92 / 2.71 / 2.14
Min. / rated / max. COP at −15 °C1.43 / 1.99 / 1.991.79 / 2.05 / 2.05
Coldest point (different temperatures)
Test temperature−20 °C (−4 °F)−35 °C (−31 °F)
Max. capacity at the coldest point8,010 BTU/h9,100 BTU/h
Max. COP at the coldest point1.791.33
Certification
RefrigerantR-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)R-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34)
ENERGY STAR · cold climateYes NEEP, Nov. 9, 2026Yes NEEP, Nov. 9, 2026
AHRI certificate · NEEP record215413007 · 389313216368960 · 383065

“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. The “min. / rated / max.” capacities are those NEEP publishes for each test temperature.

Both are on the AirGreen website.

For an estimate visit or a quote on either of these units.

Sources

Documents consulted

NEEP, record 389313 (AHRI 215413007)LG KNUAB121A / KUSAB121A · consulted Nov. 9, 2026
NEEP, record 383065 (AHRI 216368960)LG KNSAL121A / KUSAL121A · consulted Nov. 9, 2026
NEEP, record 389312 (AHRI 215413008)LG KNUAK121A / KUSAB121A (ARTCOOL MIRROR R32), for the statement of the same certified values · consulted Nov. 9, 2026
LG, DUALCOOL, brochure “Climatiseur résidentiel pour zone unique” (in French)PO_LG_R32_High_Efficiency_04_25_CA_FR (© 2025) · consulted Nov. 9, 2026
LG, ARTCOOL Deluxe, brochure “Reliable Comfort, For Every Season”PO_LG_R32_ArtCool_Mirror_Deluxe_04_25_CA_EN (© 2025) · consulted Nov. 9, 2026
LG Electronics U.S.A., submittal sheet “R32 Single Zone High Efficiency Wall Mounted”, KSUAB121ASB_SZ_HighEfficiency_R32_KSUAB121A_2026_02_19_112910 · consulted Nov. 10, 2026
LG Electronics U.S.A., submittal sheet “R32 Single-Zone Art Cool Deluxe”, KSSAL121ASB_SZ_Art_Cool_Deluxe_R32_KSSAL121A_02_26 · consulted Nov. 10, 2026
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5
NRCan, HOT2000 climate mapMontréal Intl: 4,167 degree-days, −23.1 °C