Home / Comparisons / 12,000 BTU wall-mounted heat pumps
LG DUALCOOL R32 and LG ARTCOOL DELUXE R32: two certificates, degree by degree
Two 12,000 BTU LG wall-mounted heat pumps on R-32, two AHRI certificates. The NEEP record for the DUALCOOL R32 stops at −20 °C; the one for the ARTCOOL DELUXE R32 goes down to −35 °C. This page follows both certificates as the temperature drops and shows, at each published point, what each one states.
Each point is a test temperature published by NEEP. The bar covers the span of those temperatures, not the capacity.
LGDUALCOOL R32 · 12,000 BTU
KNUAB121A / KUSAB121A · AHRI 215413007
Same AHRI and NEEP certified values as the 12,000 BTU ARTCOOL MIRROR R32 (AHRI 215413008), which uses the same KUSAB121A outdoor unit.
View the product page
LGARTCOOL DELUXE R32 · 12,000 BTU
KNSAL121A / KUSAL121A · AHRI 216368960
No other NEEP record carries the KUSAL121A outdoor unit (search of Nov. 9, 2026).
View the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h (3.52 kW) at −23.1 °C, Montréal’s design temperature: 3.52 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 8,558 kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: a simplification that does not account for recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ Region V HSPF2, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.
Two thermometers, two last certified points
Each column fills down to the coldest point NEEP publishes for the unit. Move the slider or start the descent: at each temperature, you see the published value, the range between the two neighbouring values, or the last known point.
Bars: published maximum heating capacity, on the same scale from 0 to 20,000 BTU/h. Hatched bar: range between two published values. Dotted outline: last published point, at its own temperature.
15 °C separate the two last certified points. The NEEP record for the DUALCOOL R32 stops at −20 °C, with 8,010 BTU/h maximum. The one for the ARTCOOL DELUXE R32 still has a point at −35 °C, with 9,100 BTU/h. These two values were measured at different temperatures: they do not compare with each other.
What is identical, what changes
Both units carry the ENERGY STAR cold climate designation. So the difference is not in the designation: it is in the values each certificate and each brochure publishes.
Identical on both
- RefrigerantR-32
- Rated cooling capacity, certified12,000 BTU/h
- ENERGY STAR cold climate designation (NEEP)Yes
- Base pan heater, per the NEEP record90 W
- Liquid – gas piping diameters1/4 – 3/8 in
- Length without added refrigerant41 ft
- Compressor type, per LGTwin rotary
Different: DUALCOOL R32, then ARTCOOL DELUXE R32
Certified values: NEEP, records 389313 and 383065. Declared values: LG brochures of the 04_25 series. The detail, with the conditions of each measurement, is in the sections that follow.
Below −15 °C: every published value, down to −35 °C
Below −15 °C, NEEP certifies one point for each unit: −20 °C for the DUALCOOL R32, −35 °C for the ARTCOOL DELUXE R32. The 2025 LG brochure for the ARTCOOL DELUXE adds the maximum capacity at −18, −20 and −25 °C. Between two published values, we show the range; nothing is calculated.
At −15 °C, both values come from NEEP. At −20 °C, the DUALCOOL R32 value is certified and repeated in its brochure; the ARTCOOL DELUXE R32 value comes from its LG brochure: same temperature, but a certified value on one side and a manufacturer value on the other. Below −20 °C, only the ARTCOOL DELUXE R32 has published values.
What LG states as a percentage of rated capacity
The LG brochures express maximum heating capacity relative to each model’s rated capacity: 13,600 BTU/h for the DUALCOOL R32, 13,000 BTU/h for the ARTCOOL DELUXE R32. The bases differ; so the percentages are read model by model. The line marks 100%.
What LG writes for each model, feature by feature
The features come from two kinds of LG documents: the Canadian brochure for each series and the LG Electronics U.S.A. submittal sheet for the same model number. When neither mentions a feature, we say so: that does not mean the feature does not exist.
An operating range says how far down the unit is designed to heat; the capacity at each temperature is in the Extreme cold section.
Both NEEP records list a 90 W element, on at 0 °C and below in heating mode.
The Canadian brochures do not mention Wi-Fi; the submittal sheets do.
LG describes a presence sensor built into the indoor unit, which adjusts the airflow when the room is empty.
Each document names maintenance in its own words.
Airflow rates published by LG for each model, maximum speed.
Wording repeated as LG writes it.
Control features named in the submittal sheets.
Useful for a room that needs cooling even in winter.
| Documented feature | DUALCOOL R32 | ARTCOOL DELUXE R32 |
|---|---|---|
| Base pan heater | Yes brochure 04_25; NEEP record: 90 W, on at 0 °C and below, in heating mode | Yes Built-in Base Pan Heater; NEEP record: 90 W, on at 0 °C and below, in heating mode |
| Wi-Fi app | Yes ThinQ, LG U.S.A. submittal sheet | Yes ThinQ, LG U.S.A. submittal sheet |
| Built-in occupancy sensor | Not published by the manufacturer brochure 04_25 and submittal sheet | Yes Built-in Occupancy Sensor |
| Humidity sensor | Not published by the manufacturer brochure 04_25 and submittal sheet | Yes Humidity Sensor / Control |
| Filter and automatic cleaning | Yes Self-cleaning indoor coil; 3M Micro Filter | Yes Auto Clean+ |
| Refrigerant leak detection | Yes IDU R32 leak detection sensor | Not published by the manufacturer brochure 04_25 and submittal sheet |
| Automatic restart | Yes Auto Restart; 24 h timer | Yes Auto Restart / Auto Changeover |
| Published fan speeds | 4 459 / 388 / 318 / 194 CFM in cooling | 4 494 / 424 / 318 / 219 CFM in cooling |
| Cooling in cold weather | Yes down to −10 °C; −18 °C with the optional kit | Yes down to −10 °C; −18 °C with the optional kit |
| Compressor | Twin rotary brochure 04_25 | Twin rotary Twin-Rotary, brochure 04_25 |
Indoor unit sound, fan speed by fan speed
Published indoor sound pressure
Each point is a fan speed published by LG, in heating mode.
How to read these figures. The lower the decibels, the quieter the unit. Each point is one published fan speed. A rise of 10 dB(A) is heard as roughly twice as loud.
Why this is not a ranking. Both sets of values come from LG brochures of the same year, with the same labels. LG does not specify the distance or the measurement room there. The gap is 1 dB(A) at the low and high speeds, and zero at the medium speed.
Measurements taken by the manufacturer using its own method, not described in the brochures: declared values, to be read as such.
Two different sizes, inside and out
The ARTCOOL DELUXE R32 is wider and deeper on the wall, and its outdoor unit weighs 30.4 lb more. The DUALCOOL R32 accepts longer piping.
The two indoor units, widths to the same scale




Width of the unit only, per LG. The clearances around the indoor unit and the outdoor unit are given in each model’s installation manual.
The piping length between the two units
Lengths and added refrigerant per the LG brochures: minimum 9.8 ft for both; maximum 82 ft for the DUALCOOL R32 and 65.6 ft for the ARTCOOL DELUXE R32. Diagram: the exact amount is calculated by the installer.
| Installation, per the LG brochures | DUALCOOL R32 | ARTCOOL DELUXE R32 |
|---|---|---|
| Maximum piping length | 82 ft minimum 9.8 ft | 65.6 ft minimum 9.8 ft |
| Precharged length | 41 ft 0.16 oz per ft beyond | 41 ft 0.16 oz per ft beyond |
| Factory R-32 precharge | 28.9 oz | 40.6 oz |
| Maximum height difference | 49.2 ft | 39.4 ft |
| Liquid – gas line diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 30 5/16 × 21 15/32 × 11 11/32 in, 68.8 lb | 34 1/4 × 25 19/32 × 13 in, 99.2 lb |
| Indoor unit, weight | 32 15/16 × 12 1/8 × 7 7/16 in, 19.7 lb | 35 1/4 × 12 3/32 × 9 1/4 in, 24.3 lb |
| Electrical protection | MCA 12 A · MOCP 15 A | MCA 15 A · MOCP 20 A |
| Outdoor unit sound, maximum | 47 dB(A) in cooling · 51 dB(A) in heating | 48 dB(A) in cooling · 50 dB(A) in heating |
| Dehumidification | 1.3 L/h 2.75 US pints/h per LG | 1.7 L/h 3.59 US pints/h per LG |
| Stated heating / cooling range | −20 to 18 °C / −10 to 48 °C heating at wet-bulb temperature | −35 to 18 °C / −10 to 48 °C heating at wet-bulb temperature; 18.3 and 47.8 °C per LG |
Questions about this pair
Both have the ENERGY STAR cold climate designation: where is the difference?
In the certified points. At −15 °C, NEEP publishes 10,000 BTU/h maximum for the DUALCOOL R32 and 14,700 BTU/h for the ARTCOOL DELUXE R32. The coldest point of the first is at −20 °C (8,010 BTU/h), that of the second at −35 °C (9,100 BTU/h).
What does LG publish for the DUALCOOL R32 below −20 °C?
Nothing. Its brochure states a heating range from −20 to 18 °C, wet bulb, and its NEEP record stops at −20 °C. This page invents nothing colder: it shows the last published point, with its temperature.
Why does LG write 74% for one and 113% for the other at −15 °C?
LG relates maximum capacity to each model’s rated heating capacity: 10,000 ÷ 13,600 = 74% for the DUALCOOL R32, 14,700 ÷ 13,000 = 113% for the ARTCOOL DELUXE R32. The two bases are not the same; the values in BTU/h, however, compare at the same temperature.
Which one costs less to run?
With our method, the gap comes from the certified efficiencies: HSPF2 Region V of 8.0 and 8.4, SEER2 of 22.5 and 25.5. The “Cost by season” module shows the exact gap, in dollars, for your hours of use and the price per kWh.
Do the two units take up the same space?
No. The DUALCOOL R32 indoor unit is 32 15/16 in wide and 7 7/16 in deep; the ARTCOOL DELUXE R32 one, 35 1/4 in and 9 1/4 in. The outdoor unit weighs 68.8 lb for the first and 99.2 lb for the second, per LG.
Does the DUALCOOL R32 share its certificate with another model?
It has its own certificate, AHRI 215413007. The 12,000 BTU ARTCOOL MIRROR R32 (KNUAK121A) uses the same KUSAB121A outdoor unit, and its AHRI certificate 215413008 carries the same AHRI and NEEP certified values (NEEP records 389313 and 389312, consulted November 9, 2026). The indoor unit, however, is different.
What about the warranty?
LG publishes its terms for each model. The warranty documents come with the quote.
The AHRI certificate values, published by NEEP
| Certified value | DUALCOOL R32 | ARTCOOL DELUXE R32 |
|---|---|---|
| Seasonal efficiencies | ||
| SEER2 | 22.5 | 25.5 |
| EER2 | 12.8 | 13.8 |
| HSPF2 Region IV | 10.5 | 11.2 |
| HSPF2 Region V | 8.0 | 8.4 |
| Rated capacity at 35 °C (cooling) | 12,000 BTU/h | 12,000 BTU/h |
| Heating, min. / rated / max. capacity | ||
| Min. / rated / max. capacity at 8.3 °C | 1,023 / 13,600 / 19,040 | 3,070 / 13,000 / 20,000 |
| Min. / rated / max. capacity at −8.3 °C | 1,877 / 8,500 / 12,400 | 2,627 / 8,400 / 16,820 |
| Min. / rated / max. capacity at −15 °C | 1,706 / 10,000 / 10,000 | 2,388 / 14,700 / 14,700 |
| Min. / rated / max. COP at 8.3 °C | 1.50 / 3.83 / 2.83 | 4.74 / 4.10 / 2.93 |
| Min. / rated / max. COP at −8.3 °C | 1.49 / 2.86 / 2.19 | 1.92 / 2.71 / 2.14 |
| Min. / rated / max. COP at −15 °C | 1.43 / 1.99 / 1.99 | 1.79 / 2.05 / 2.05 |
| Coldest point (different temperatures) | ||
| Test temperature | −20 °C (−4 °F) | −35 °C (−31 °F) |
| Max. capacity at the coldest point | 8,010 BTU/h | 9,100 BTU/h |
| Max. COP at the coldest point | 1.79 | 1.33 |
| Certification | ||
| Refrigerant | R-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34) | R-32 GWP 675 (IPCC AR4), class A2L (ASHRAE 34) |
| ENERGY STAR · cold climate | Yes NEEP, Nov. 9, 2026 | Yes NEEP, Nov. 9, 2026 |
| AHRI certificate · NEEP record | 215413007 · 389313 | 216368960 · 383065 |
“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. The “min. / rated / max.” capacities are those NEEP publishes for each test temperature.
Both are on the AirGreen website.
For an estimate visit or a quote on either of these units.
Documents consulted
Data verified on November 9, 2026. Certified values: AHRI certificates published by NEEP. Declared values (sound, dimensions, piping, features): the manufacturer’s documents cited above. When two sources differ, the AHRI certificate prevails.
LG, DUALCOOL, ARTCOOL, LGRED and ThinQ are trademarks of their respective owners. Logos are used only to identify the products. AirGreen is a dealer for this brand; this page is not produced, sponsored or endorsed by the manufacturer.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca.