MIDEA EVOX G3 and SAMSUNG Hylex Premium, 36,000 BTU

Home / Comparisons / 3-ton central heat pumps

Comparison · Central heat pump · R-454B · 3 tons

MIDEA EVOX G3 and SAMSUNG Hylex Premium, 3 tons, step by step

Two 3-ton central heat pumps on R-454B, offered by AirGreen and ENERGY STAR cold climate per NEEP. Their certificates give the same cooling capacity, 36,000 BTU/h. In heating, NEEP tests them at the same three temperatures, then one last time at −30 °C for the EVOX G3 and at −25 °C for the Hylex Premium.

SEER218.0and17.5
HSPF2 Region V8.2and6.8
BTU/h max. at −15 °C37,400and39,000
Coldest point−30 °Cand−25 °C
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 36,000 BTU/h house in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. Both systems are certified at 36,000 BTU/h in cooling; the winter gap comes from their Region V HSPF2, 8.2 and 6.8.

How this amount is calculated
  1. Heat needed over the winter. A house whose heat loss reaches 36,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 36,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. The network access fee, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

Four steps

Two certified staircases on the same temperature axis

Each step is a test temperature from the certificate, placed at its true position on the axis. Its height is the certified maximum heating capacity. At the first three temperatures, the steps of the two units sit side by side; the last one is at −30 °C for the EVOX G3 and at −25 °C for the Hylex Premium.

EVOX G3 MIDEAHylex Premium SAMSUNGYellow band: same test temperature for both. Dotted lines: they link each unit’s steps; nothing is measured between two steps. Source: NEEP, records 387396 and 506852.

At −8.3 °C, the Hylex Premium certificate gives a minimum capacity of 20,200 BTU/h, a rated capacity of 21,000 and a maximum capacity of 42,000; the page repeats these values as they are published. At the last step, the certificate gives a minimum capacity and a maximum capacity, with no rated value.

Extreme cold

Below −15 °C: every published figure, at its exact temperature

Only one row compares directly: −15 °C, where NEEP certifies both units. Lower down, the temperatures or the sources differ. SAMSUNG publishes a capacity table for the Hylex Premium outdoor unit; MIDEA does not publish one for the EVOX G3. At each temperature, the page says where the figure comes from.

What each manufacturer also writes. MIDEA: the submittal sheet for this combination states “100% heating output down to −13°F” and specifies in a note that its rated heating capacity at −25 °C (−13 °F) is 100%. SAMSUNG: the Hylex brochure states 100% of rated heating capacity at −20 °C (−4 °F) for the 3-ton Premium, and a heating range down to −25 °C. These statements are percentages; the page does not convert them to BTU/h.
Documented features

What each manufacturer writes, row by row

MIDEA EVOX G3 submittal sheet, installation manual and leaflet; SAMSUNG Hylex submittal sheet, technical data book, installation manual and brochure. Each row repeats what the manufacturer writes.

Compressor

EVOX G3: twin-cylinder rotary EKPQ420D1UMUA; “M-Powevi” vapour injection in extreme cold (leaflet).

Hylex Premium: variable-speed twin BLDC rotary UF5LF3450FJXSG; two outdoor fans (data book).

Extreme cold and defrost

EVOX G3: heating stated down to −30 °C; enhanced defrost setting; base pan and crankcase heaters included as standard.

Hylex Premium: heating stated down to −25 °C; base pan heater included as standard and crankcase heating; adjustable compressor shut-off (brochure).

Fan and airflow

EVOX G3: 5 speeds, 971 to 1,236 CFM; constant airflow up to 1.0 in w.c.

Hylex Premium: ECM motor with 5 settings; 1,389 CFM at the factory setting at 0.1 in w.c., up to 1,534; table up to 1.0 in w.c. (installation manual).

Controls and thermostat

EVOX G3: MIDEA 120N wall controller, offered with built-in Wi-Fi, a wireless remote or another manufacturer’s 24 V thermostat (submittal sheet).

Hylex Premium: 24 V thermostat through the ACU module MXD-U001XN, which SAMSUNG requires and sells separately; SmartThings Wi-Fi through this module. The Hylex package sold by AirGreen includes a thermostat.

Optional electric backup heat

EVOX G3: three-stage kit, up to 25 kW (submittal sheet, leaflet).

Hylex Premium: kits HA05E0CH1 to HA20E0CH1 (brochure); dual-fuel operation possible with a furnace.

Refrigerant and leak detection

EVOX G3: R-454B, 127 oz from the factory. Leak detection is not described in the submittal sheet; that does not mean it is absent.

Hylex Premium: R-454B, 158.4 oz from the factory; leak sensor connected to a safety board in the indoor unit (installation manual).

Sound

The sound of each one, per its manufacturer

MIDEA publishes a “Noise Level” for the indoor unit, by speed, and for the outdoor unit, with no method. SAMSUNG publishes the sound pressure of the outdoor unit, measured in an anechoic chamber, in cooling and in heating. The methods differ: read the values separately.

dB(A)

How to read these numbers. dB(A) measures noise level as the ear perceives it: the lower the number, the quieter the unit. Each dot is a value published by the manufacturer.

Why this is not a ranking. MIDEA does not state its method; SAMSUNG measures in an anechoic chamber. Different method — not comparable.

Indoor unit, in the basement or a closet

Published values

Hylex Premium: the SAMSUNG documents consulted (submittal sheet, data book, installation manual) do not give the sound of the HH36MACC11H1 indoor unit.

Outdoor unit, outside

Published values

SAMSUNG also publishes a sound power of 75 dB(A) under the ISO 3741 standard; that is a different quantity from sound pressure.

Measurements taken by each manufacturer with its own method: read them separately, not as a ranking.

Installation

Outside, at the same scale, then the piping

Outdoor units, width and height to scale

MIDEA MO1SE-H36B-2A outdoor unit
SAMSUNG AC036FCUPCG outdoor unit
EVOX G3 38 9/16 in wide, 38 3/8 in high, 204 lbHylex Premium 37 in wide, 55 7/8 in high, 229.3 lb

Frames drawn at the published width and height, at the same scale; each photo is placed in its frame. Depth: 16 3/8 in and 13 in. The EVOX G3 has one fan, the Hylex Premium has two.

Line-set length and refrigerant to add

AirGreen calculation from the manufacturers’ documents: length beyond 25 ft × 0.7 oz per foot (MIDEA) or 0.5 oz per foot (SAMSUNG). SAMSUNG precharges the unit for 24.6 ft (7.5 m). Maximum published length: 246 ft (MIDEA) and 164 ft (SAMSUNG).

InstallationEVOX G3Hylex Premium
Maximum piping length246 ftMIDEA submittal sheet and installation manual, rev. 5.164 ftSAMSUNG submittal sheet and data book (50 m).
Precharged length25 ft0.7 oz of R-454B per foot beyond.24.6 ft0.5 oz of R-454B per foot beyond 25 ft.
Maximum height difference98 ft98 ft
Liquid – gas line diameters3/8 – 3/4 in3/8 – 7/8 inGas: 3/4 in minimum, 1 1/8 in maximum, per the submittal sheet.
Outdoor unit W × H × D, weight38 9/16 × 38 3/8 × 16 3/8 in, 204 lb37 × 55 7/8 × 13 in, 229.3 lb
Indoor unit, weight17 1/2 × 58 1/8 × 21 1/2 in, 149 lbDimensions and weight are not in the SAMSUNG documents consultedIndoor unit submittal sheet, data book and installation manual.
Electrical protectionoutdoor unit, 208/230 VMCA 29 A · MOP 30 AMCA 33.3 A · max. breaker 40 A
Factory refrigerant charge127 oz of R-454B158.4 oz of R-454B
Stated heating / cooling range−30 to 24 °C / −30 to 50 °C−25 to 24 °C / −20 to 52 °C

Sources: MIDEA “Extreme Heat AHU Series” submittal sheet and MIDEA EVOX Extreme Heat installation manual; SAMSUNG AC036FCUPCG/AA submittal sheet, SAMSUNG Hylex technical data book v2.0 and SAMSUNG installation manual IM-HFAH-A2L-679608-01. No minimum line-set length appears in the documents consulted from either manufacturer.

Frequently asked questions

What people ask about these two central systems

Where do the two systems differ the most?

On seasonal heating efficiency. The certified Region V HSPF2, the coldest region in the standard, is 8.2 for the EVOX G3 and 6.8 for the Hylex Premium; in Region IV, 10.0 and 8.5. The certified maximum capacities are close at −8.3 °C (41,500 and 42,000 BTU/h) and at −15 °C (37,400 and 39,000 BTU/h).

Why is the last step not at the same temperature?

Each manufacturer has its unit certified at the coldest temperature of its choice. NEEP publishes −30 °C for the EVOX G3 (27,600 BTU/h maximum) and −25 °C for the Hylex Premium (27,000 BTU/h maximum). These two values do not compare directly.

What is known about the Hylex Premium below −25 °C?

SAMSUNG states a heating range down to −25 °C and publishes no capacity lower down. At −30 °C, the page therefore repeats the last published point, 27,000 BTU/h at −25 °C.

Is the thermostat included?

The SAMSUNG Hylex package sold by AirGreen includes a thermostat. SAMSUNG also requires the ACU module MXD-U001XN, which it sells separately. For the EVOX G3, the written quote specifies the control supplied.

Is the winter cost very different?

The estimated cost uses Region V HSPF2, 8.2 and 6.8: the gap shown above follows from that, under the same calculation conditions. In summer, the SEER2 values are 18.0 and 17.5.

Which one makes less noise?

MIDEA publishes 63 dB(A) for the outdoor unit, with no method; SAMSUNG publishes 55 dB(A) in cooling and 57 dB(A) in heating, as sound pressure measured in an anechoic chamber. The methods differ: these numbers cannot be used to rank the units.

Are they eligible for rebates?

Per NEEP, both combinations are ENERGY STAR and ENERGY STAR cold climate. Eligibility depends on the official list in force on the date of purchase; this page promises no amount.

Certified data sheet

All the AHRI and NEEP values

Certified valueEVOX G3Hylex Premium
Cooling
Rated capacity at 35 °C36,000 BTU/h36,000 BTU/h
SEER218.017.5
EER212.012.0
Heating, same conditions
HSPF2 Region IV10.08.5
HSPF2 Region V8.26.8
8.3 °C: min. / rated / max.BTU/h11,400 / 37,000 / 47,00011,000 / 36,000 / 55,000
8.3 °C: COP min. / rated / max.4.45 / 3.50 / 3.274.61 / 3.40 / 2.27
−8.3 °C: min. / rated / max.BTU/h11,000 / 33,000 / 41,50020,200 / 21,000 / 42,000
−8.3 °C: COP min. / rated / max.2.58 / 2.50 / 2.212.79 / 2.48 / 2.43
−15 °C: min. / rated / max.BTU/h8,900 / 37,400 / 37,40015,600 / 39,000 / 39,000
−15 °C: COP min. / rated / max.2.16 / 1.90 / 1.902.48 / 1.90 / 1.90
Coldest point — different temperatures, not comparable
Test temperature−30 °C (−22 °F)−25 °C (−13 °F)
Min. / max. capacity4,700 / 27,600 BTU/h12,000 / 27,000 BTU/h
COP at maximum capacity1.561.70
Listings and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
AHRI certificate · NEEP record215471343 · 387396218158147 · 506852
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-454B · GWP 466 · A2LR-454B · GWP 466 · A2L

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COPs at each point are not highlighted; they are compared in “Four steps” and “Extreme cold”.

Both are on the AirGreen website.

To choose for your home, talk it over with our team: bring the heated floor area, the condition of your ducts and your current heating.

Sources and documents

Where every figure comes from

NEEP, record 387396 (MIDEA EVOX G3)AHRI 215471343 · consulted November 9, 2026 NEEP, record 506852 (SAMSUNG Hylex Premium)AHRI 218158147 · consulted November 9, 2026 MIDEA, MAUSE-H36B-2A / MO1SE-H36B-2A submittal sheet“Extreme Heat AHU Series” · undated · sound, dimensions, weight, electrical, piping · consulted November 9, 2026 MIDEA, EVOX Extreme Heat installation manual (MO1HE and MO1SE)Rev. 5, October 23, 2025 · piping, ranges · consulted November 9, 2026 MIDEA, EVOX G3 Central Ducted Systems leaflet2025 · compressor, electric backup heat
SAMSUNG, AC036FCUPCG/AA submittal sheet (CCG36UPF)© 2026 Samsung HVAC, file dated February 11, 2026 · dimensions, weight, sound, electrical, piping, ranges, accessories · verified November 9, 2026
SAMSUNG, Hylex Standard and Premium technical data book (R-454B, 60 Hz)Ver. 2.0, August 29, 2025 · p. 12, 49, 55 (heating capacity table), 104 (ranges), 127 · verified November 9, 2026
SAMSUNG, indoor unit installation manual IM-HFAH-A2L-679608-01March 2026 · airflow, clearances, leak sensor, ACU module · verified November 9, 2026
SAMSUNG, Hylex R-454B brochure (HYLEXBR 02.2026-V2, rev. 260413B)February 2026 · extreme-cold statements, backup heat kits, ACU module · verified November 9, 2026
Hydro-Québec, Electricity RatesIn effect April 1, 2026 · Rate D, article 2.5 · estimated operating cost Natural Resources Canada, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C), design temperature −23.1 °C · consulted November 9, 2026