Comparisons · Floor consoles
HITACHI RAF-FJ12QHAA and MIDEA MFAHU-H12B-2A, two 12,000 BTU consoles
Two floor consoles, and the question installers hear most: does it stand on the floor, hang on the wall or go into the wall? Here is what each manufacturer documents, with one basic difference: the HITACHI console is sold with a multi-zone outdoor unit, the MIDEA with its own outdoor unit.


airHome Multi console
Indoor RAF-FJ12QHAA · with a multi-zone outdoor unit, for example RAM-G24N3HAA
Sold on a multi-zone system; no single-zone AHRI certificate for this console.
View the product pageXtreme Heat floor console
Indoor MFAHU-H12B-2A · outdoor MO1HS-H12B-2A · AHRI 215471433
Single-zone, R-454B refrigerant.
View the product pageWhy this page does not put a figure on electricity cost
Our comparison pages calculate the cost of two single-zone systems from their certified HSPF2 Region V and SEER2. The HITACHI console is only sold with a multi-zone outdoor unit: its efficiency depends on the whole combination, and no certificate gives it its own SEER2 and HSPF2 comparable with the MIDEA’s. The calculation would not be made under the same conditions, so we do not make it.
How each console is mounted, according to its manufacturer
Pick a way to mount the unit. Each console appears on a wall section to scale when its document shows or describes that option; otherwise its outline stays dashed.
HITACHI RAF-FJ12QHAA
MIDEA MFAHU-H12B-2A
Side sections to the same scale (1 mm = 0.42 px), diagram. HITACHI: the RAF-FJ12QHAA submittal (Nov. 2024) shows floor mounting, with floor fixing holes and a rear anchor-bolt hole, and a “built-in installation” (recessed) variant; it does not describe hanging the unit on the wall. MIDEA: Midea’s “Console” brochure presents it standing on the floor or hung low on the wall, under a window; the submittal does not describe recessed mounting. Each manufacturer’s installation manual sets the clearances and the mounting details.
Below −15 °C, what is published
The MIDEA has two certified points below −8 °C: at −15 °C and at −30 °C. The capacity of a HITACHI console depends on the multi-zone outdoor unit and the other heads connected: no document puts a figure on it for the console alone.
What each manufacturer writes, line by line
Only the features named in each manufacturer’s submittal. A feature a sheet does not name is not necessarily missing.
| Feature | HITACHI RAF-FJ12QHAA | MIDEA MFAHU-H12B-2A |
|---|---|---|
| Wi-Fi and app | Optional: SPX-WFA01 adapterHITACHI sheet | Yes, with the Wi-Fi dongle or a Wi-Fi wall controlMIDEA sheet |
| Wireless remote | Yes, included: RAF-FJ07QHAA005HITACHI sheet | Yes, offered among the controlsMIDEA sheet |
| Wired wall control | Optional: SPX-URFG1HITACHI sheet | Optional: 120N(X6), 120N(X6W), 120LMIDEA sheet |
| Indoor fan | 4 named speeds: high, medium, low, super lowHITACHI sheet | 5 named speeds, setting from 1 to 100%MIDEA sheet |
| Air outlets | Not published by the manufacturer in the submittalHITACHI sheet | Two air outletsMIDEA sheet |
| Refrigerant leak detection | Not published by the manufacturer in the indoor unit sheetHITACHI sheet | Yes, built-in sensor, plus a humidity sensorMIDEA sheet |
| Dry contacts and alarm signals | Optional: SPX-WDC3, SPX-WDC8HITACHI sheet | Third-party 24 V thermostat with 24 V interfaceMIDEA sheet |
What each manufacturer publishes for the indoor unit
How to read these figures. dB(A) measures sound pressure; the lower the figure, the quieter the unit. Each dot is a published fan speed, in cooling.
Why this is not a ranking. HITACHI publishes three speeds, the MIDEA five, and neither sheet states the measuring distance.
Indoor unit
Published sound pressure by speed
Measurements taken by each manufacturer with its own method: they place each unit, they do not decide between them.
In heating, HITACHI publishes 41, 31 and 23 dB(A). The MIDEA MO1HS-H12B-2A outdoor unit: 55.5 dB(A); HITACHI’s depends on the chosen multi-zone unit.
What to know before installation
The MIDEA is wider and taller, the HITACHI deeper. Both connect with 1/4 and 3/8 in lines. For the HITACHI, piping lengths follow the multi-zone outdoor unit.
Both indoor units, front view, to the same scale
Front diagrams to the same scale: 100% of the area = 1,000 mm. Sizes converted from the published inches. The real photos are at the top of the page.
| Installation | HITACHI RAF-FJ12QHAA | MIDEA MFAHU-H12B-2A |
|---|---|---|
| Maximum piping length | Depends on the chosen multi-zone outdoor unit | 82 ft (25 m) |
| Pre-charged length | Depends on the chosen multi-zone outdoor unit | 25 ft (7.5 m)then 0.16 oz per foot |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Indoor unit W × H × D, weight | 29.5 × 23.2 × 8.6 in, 32.4 lb | 31-1/4 × 24-1/2 × 7-7/8 in, 33 lb |
| Power supply | From the outdoor unit; 14 to 18 AWG 4-conductor cable | From the outdoor unit, 208/230 V; 14/4 AWG cable |
| Dehumidification | Not published by the manufacturer in the submittal | 1.48 L/h |
| Condensate drain | 0.63 in (16 mm) | Not published by the manufacturer in the submittal |
What people ask us about these two consoles
Which one can hang on the wall?
Midea presents its console standing on the floor or hung low on the wall, under a window. The HITACHI submittal shows floor mounting, fixed to the floor and anchored at the back, and a recessed variant; it does not describe hanging the unit.
Which one can be recessed?
The drawings in the HITACHI sheet show a “built-in installation”, meaning recessed. The MIDEA documents consulted do not describe recessing this console.
Why no electricity cost on this page?
The HITACHI console only exists in multi-zone, with no single-zone certificate. Without SEER2 and HSPF2 measured under the same conditions as the MIDEA, we do not publish a compared estimate.
Can a HITACHI console be installed alone in a room?
It connects to an airHome Multi multi-zone outdoor unit, which can supply other heads. The number and mix of heads are chosen at quote time, and the certificate of that combination gives the efficiency.
Does the MIDEA heat at −30 °C?
Yes, according to its certificate: 4,800 BTU/h maximum at −30 °C (−22 °F), and 11,300 BTU/h at −15 °C. Its published operating range goes down to −22 °F.
The two indoor units, side by side
| Measure | HITACHI RAF-FJ12QHAA | MIDEA MFAHU-H12B-2A |
|---|---|---|
| System | ||
| AHRI certificate · NEEP record | No single-zone certificate; certificate of the multi-zone combination | 215471433 · NEEP 387306 |
| Refrigerant | R-32 (GWP 675, IPCC AR4; class A2L, ASHRAE 34)airHome Multi series | R-454B (GWP 466, IPCC AR4; class A2L, ASHRAE 34) |
| Rated capacity at 35 °C, cooling | 12,000 BTU/hnominal capacity of the indoor unit | 12,000 BTU/hcertified, with MO1HS-H12B-2A |
| Indoor unit | ||
| Indoor unit W × H × D, weight | 749 × 589 × 218 mm, 32.4 lb | 794 × 621 × 200 mm, 33 lb |
| Fan, published speeds | 4 speeds | 5 speeds |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
MIDEA certified values (NEEP, AHRI 215471433): SEER2 25, EER2 12.5, HSPF2 Region IV 10.5 and Region V 8.3; heating at 8.3 °C 4,400 / 12,000 / 16,100 BTU/h (min. / rated / max.); at −15 °C 11,300 BTU/h; ENERGY STAR and Cold Climate.
Both are on AirGreen’s website.
A question about mounting a console, or about a multi-zone system? Call us or request a quote.
Documents consulted
Data verified November 10, 2026. Performance: AHRI certificate and the NEEP database. Dimensions, sound, connections, mounting and features: according to the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. HITACHI, airHome and MIDEA are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer for both brands; this page is not produced, sponsored or endorsed by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong to you? Write to us: every reported figure is checked again.