ZEPHYR CB22 R-32 and ZEPHYR CB25 R-454B, 12,000 BTU

Home / Comparisons / ZEPHYR

Comparison · ZEPHYR · 12,000 BTU wall units

ZEPHYR CB22 R‑32 and CB25 R‑454B: what changed, number by number

Two 12,000 BTU ZEPHYR wall units, at 208/230 V. The CB22 uses R-32, the CB25 R-454B. According to the ZEPHYR brochures, the indoor unit has the same dimensions and the same speeds; the outdoor unit, the expansion device, the heating range and the certified ratings change.

HSPF2 Region V: 7.5 and 9.0 À −15 °C : 7,500 and 11,000 BTU/h Heating range: −25 °C and −30 °C
Season cost

What the electricity costs, in dollars, winter and summer

Estimate for a 12,000 BTU/h zone in Montréal, with the same formula as on all our comparison pages. The AHRI certificates give an HSPF2 Region V of 7.5 for the CB22 and 9.0 for the CB25, and a SEER2 of 20 and 23.

How this amount is calculated
  1. Heat to supply in winter : 12,000 BTU/h (3.52 kW) × 24 h × 4,167 degree-days (base 18 °C) ÷ (18 − (−23.1 °C)), prorated to the heating hours you choose. Degree-days and design temperature: Natural Resources Canada, HOT2000 climate map, Montréal International station. At 24 h a day: 8,558 kWh of heat.
  2. Heat pump electricity : heat × 3.412 ÷ HSPF2 Region V from the AHRI certificate (7.5 for the CB22, 9.0 for the CB25). Region V includes the electric backup set by the standard.
  3. Electric baseboards : 1 kWh of electricity per kWh of heat.
  4. Cooling : 12,000 BTU/h ÷ SEER2 (20 and 23) × hours per day × 60 days ÷ 1,000, the method of Hydro-Québec’s air-conditioning calculator.
  5. Price : Hydro-Québec Rate D in effect on April 1, 2026, taxes (GST and QST) included; system access charge excluded.

Two simplifications: fewer heating hours reduce the heat pro rata, without counting the recovery after a temperature setback; 24 h of cooling assumes rated capacity all day, which is a maximum, since a variable-speed unit slows down. The result is an estimate, not a bill.

What changed

From the CB22 to the CB25, step by step

Each step compares a value from the ZEPHYR brochure or the AHRI certificate. Click a step: the photo shows the part concerned. For the choice between R-32 and R-454B in general, see our guide on the two refrigerants.

    ZEPHYR outdoor unit (photo from the AirGreen product page) ZEPHYR indoor unit (photo from the AirGreen product page)

    ZEPHYR indoor unitIndoor unit: same published dimensions33 7/16 × 11 9/16 × 8 1/16 in in both brochures; 5 fan speeds, from 28 to 46 dB(A).
    ZEPHYR remoteSame features listedNight, quiet, iFeel and 4D modes, 8 °C maintenance heating, self-cleaning, heated base pan, LED remote: the list is identical in both brochures.
    Same lines and same height difference1/4 and 3/8 in lines, precharged for 25 ft, 50 ft height difference, GMCC rotary compressor, 15 A maximum protection at 208/230 V.
    Extreme cold

    Below −15 °C: every published point

    In Montréal, the January mean is −9.2 °C and the building design temperature is −23 °C. NEEP certifies both units at −15 °C; the coldest certified point is −20.6 °C for the CB22 and −25 °C for the CB25. The CB25 brochure adds a value at −20 °C (−5 °F), outside the certificate.

    At −15 °C, same temperature7,500 BTU/h for the CB22, 11,000 BTU/h for the CB25, according to NEEP.
    Below −20.6 °C for the CB22ZEPHYR states heating down to −25 °C, with no capacity figure below −20 °C.
    Below −25 °C for the CB25ZEPHYR states heating down to −30 °C, with no capacity figure below −25 °C.
    Sound

    Five speeds, almost the same numbers

    Both brochures publish the indoor unit’s sound pressure at each of the five speeds, and 53 dB(A) for the outdoor unit. Only the high speed differs, by half a decibel.

    In the room, the indoor unit

    By fan speed, according to the ZEPHYR brochures

    Frequently asked questions

    What people ask us about the CB22 and the CB25

    Which indoor unit comes with the 12,000 BTU CB22?

    The current AHRI certificate, 218325270, covers the ZE-12CB22AI indoor unit with the ZE-12CB22O outdoor unit. The ZEPHYR brochure names the model ZE-12CB22, without a suffix. The exact number appears on the quote.

    Can a CB22 be switched to R-454B?

    Each unit is certified with its refrigerant: the CB22 certificate covers R-32, the CB25 certificate R-454B. The two brochures publish different charges, expansion devices and outdoor units.

    Are R-454B and R-32 in the same safety class?

    Yes, both are classed A2L under the ASHRAE 34 standard: lower toxicity, low flammability. Their GWP differs: 675 for R-32 and 466 for R-454B, according to the IPCC Fourth Assessment Report. Our R-32 or R-454B guide covers both in detail.

    Why does the CB25 show 11,000 BTU/h at −15 °C, and its brochure 10,600?

    The AHRI certificate, published by NEEP, gives 11,000 BTU/h; the ZEPHYR brochure, 10,600 BTU/h maximum. When a source contradicts the AHRI certificate, the certificate prevails: the page uses 11,000 and mentions the other value.

    Which one to choose?

    This page does not rank the units. It shows what the certificates and brochures publish; the choice depends on the room, the heat needed in extreme cold and the location of the outdoor unit.

    Are they eligible for grants?

    Eligibility depends on the program, its official list on the purchase date and the exact unit. This page promises no amount. The warranty documents come with the quote.

    Specs

    The published values, unit by unit

    Certified values: AHRI certificates published by NEEP. Electrical, installation and sound: ZEPHYR brochures (BRO_2606). “Higher” only appears under the same conditions.

    Published valueZEPHYR CB22 R-32ZEPHYR CB25 R-454B
    AHRI certificate (NEEP)
    SEER22023
    EER2The CB22 brochure states 10.51012.25
    HSPF2 Region IV / V9.0 / 7.510.0 / 9.0
    Capacity at 8.3 °C (min. / rated / max.)BTU/h4,000 / 12,000 / 12,6003,000 / 12,000 / 13,000
    Capacity at −8.3 °C (min. / rated / max.)BTU/h3,400 / 9,000 / 9,5502,550 / 10,800 / 12,000
    Capacity at −15 °C (min. / rated / max.)BTU/h2,900 / 7,500 / 7,5002,000 / 11,000 / 11,000
    COP at −15 °C, at maximum output1.832.00
    Coldest certified point (different temperatures)
    Capacity min. / max. at the coldest pointBTU/h1,500 / 6,000 to −20.6 °C1,000 / 6,100 to −25 °C
    COP at the coldest point, at maximum output1.53 to −20.6 °C1.38 to −25 °C
    Certifications and refrigerant
    ENERGY STAR / cold climate (NEEP)No / NoYes / Yes
    AHRI certificate · NEEP record218325270 · 418044215414830 · 418302
    RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-454B · GWP 466 · A2L
    Refrigerant charge21.87 oz38.10 oz
    Electrical, ZEPHYR brochures
    Power supply208/230 V, 1 phase, 60 Hz208/230 V, 1 phase, 60 Hz
    MCA / MOPMinimum circuit ampacity / maximum overcurrent protection9.5 A / 15 A10.5 A / 15 A
    Rated current, cooling / heating5.2 / 4.8 A4.4 / 4.2 A
    Cable between units4/14, stranded copper, 600 V4/14, stranded copper, 600 V
    Installation, ZEPHYR brochures
    Liquid / gas diameters1/4 – 3/8 in1/4 – 3/8 in
    Line-set length (min. – max.)10 – 65 ft10 – 98 ft
    Precharged for25 ft25 ft
    Maximum height differenceIndoor unit higher50 ft50 ft
    Expansion deviceCapillary tubeElectronic (EEV)
    Heating operating range−25 to 24 °C−30 to 24 °C
    Cooling operating range−15 to 48 °C−15 to 48 °C
    Outdoor unit (W × H × D)28 1/8 × 21 1/4 × 9 1/2 in31 7/8 × 23 × 11 in
    Indoor unit dimensions (W × H × D)33 7/16 × 11 9/16 × 8 1/16 in33 7/16 × 11 9/16 × 8 1/16 in
    Indoor airflow (min. – max.)253 – 400 CFM253 – 394 CFM
    Sound, indoor unit (min. – max.)28 – 46 dB(A)28 – 46 dB(A)
    Sound, outdoor unit53 dB(A)53 dB(A)
    CompressorRotary, GMCCRotary, GMCC

    “Higher” (highlighted) marks the higher value of the same measurement, under the same conditions; it is never a recommendation. The coldest points are at different temperatures: nothing is highlighted there.