Model numberYC442E2S11

3.5 tons42,000 BTU/h nominal size
73 dBAsound power
R-454BCooling only208/230 V · single phase30 A max. breaker
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberYC442E2S11
ManufacturerYork
SeriesYC4 LX
Size3.5 tons (42,000 BTU/h)
RefrigerantR-454B
Minimum circuit ampacity18.9 A

The 3.5-ton YC4, when the upper floor needs more cooling

At 42,000 BTU/h, the YC442E2S11 is the 3.5-ton size of the York YC4 (LX) series, between the 3-ton and 4-ton sizes of the same series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.

The YC4 moves York's R-454B LX range one step up in efficiency, up to 16 SEER2 depending on size and match. It comes from 2 to 5 tons, with a single-stage scroll compressor and the range's G90-equivalent steel cabinet. The limited warranty is 10 years on the compressor.

The right size for your home

This size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. We always check the furnace airflow and the size of the return ducts before recommending this size.

Technical data worth knowing

For efficiency, the spec sheet gives 14.3 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 73 dBA. Electrical: 208/230 V single-phase circuit, 18.9 A minimum ampacity, 30 A maximum time-delay fuse or breaker.

The unit ships with a factory charge of 3.38 lb (1.53 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1/4 in at the base and 36 1/4 in high, with an operating weight of 230 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).

R-454B has a much lower global warming potential than the R-410A it replaces. Like any A2L refrigerant, it requires a compatible indoor section and an installation that follows the manufacturer's instructions.

This condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.

Same size, other series: York YC3 LX, York YCG LX, York YC2D LX.

What our installation includes

A Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.

  1. Free visit: we measure and check the panel and the ducts;
  2. Written quote, with the planned indoor section and electrical circuit;
  3. Installing the condensing unit on a level base, and the indoor section;
  4. Connecting the piping with a 7/8 in vapor valve, evacuation and charge adjusted to the actual length;
  5. Electrical hookup, full test run and a walk-through of how it works.

The manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Get a quote

Send us a free estimate request for the YC442E2S11: we validate the size on site and give you a written price, installation included. Financing is available.

01 · What it is for

The outdoor half of a 3.5-ton central air system

The YC442E2S11 sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.

  • Large multi-storey houses cooled through a single duct system
  • Open-plan and heavily glazed houses
  • Replacing a central air conditioner of the same size
  • Large-capacity electric furnace or fan coil
R-454B refrigerantThe new-generation refrigerant required for new air conditioners, with a lower global warming potential than R-410A.
18.9 A circuitPublished minimum circuit ampacity, with a 30 A maximum time-delay fuse or breaker.
Up to 80 ft of pipingMaximum equivalent length allowed by the manufacturer, so the unit can go where it bothers least.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
SeriesYC4 (LX)
TypeSplit central air conditioner outdoor unit, cooling only
Nominal size3.5 tons (42,000 BTU/h)
RefrigerantR-454B
CompressorScroll, single stage
Sound power73 dBA
Power supply208/230 V, single phase, 60 Hz (187 to 252 V operating)
Minimum circuit ampacity18.9 A
Max. time-delay fuse or breaker30 A
Compressor (RLA / LRA)14.3 A / 95.0 A
Fan motor (FLA)1.05 A
Liquid valve3/8 in
Vapor valve7/8 in
Factory charge3.38 lb (1.53 kg) of R-454B for 15 ft of piping
Piping lengthUp to 80 ft (24.4 m) equivalent
Low-ambient cooling55°F (12.8°C) without accessories; down to 20°F (-7°C) with the approved low-ambient kits
Dimensions (W x D x H)38 x 34 1/4 x 36 1/4 in
Operating weight230 lb (104.3 kg)
CabinetG90-equivalent steel, powder-coat paint rated for at least 500 h of salt spray (ASTM B117); top discharge
Model numberYC442E2S11
03 · Before installing

What to know before installing

  • Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
  • The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
  • 208/230 V single-phase, 60 Hz circuit: 18.9 A minimum ampacity, 30 A maximum time-delay fuse or breaker.
  • Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
  • R-454B is an A2L-class refrigerant: installation follows the manufacturer's requirements for it, with an indoor section approved for R-454B.
04 · See also

Explore the range

Same category
Central air conditioners
See all
Same brand
YORK
See all
05 · Questions

Frequently asked questions

Are my ducts big enough for 3.5 tons?

We always check this at this size. Undersized ducts make the air noisy at the grilles and reduce performance; we assess them during the free estimate.

Does this air conditioner heat the house?

No. The YC442E2S11 is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.

What indoor equipment does it work with?

A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.

What electrical circuit is needed?

A 208/230 V single-phase circuit with a 18.9 A minimum ampacity and a 30 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.

What warranty does the manufacturer offer?

According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3.5-ton central air conditioner, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.