YORK YCE LX Central Air Conditioner | 4 Tons - 48000 BTU - R410A
The 4-ton York YCE condensing unit: the outdoor half of an R-410A central air conditioner, matched with a coil or a fan coil.
Model numberYCE48B21S
514 316-2973 · sales@airgreen.ca
Quick facts
A 4-ton York for a large house on a single duct system
A 4-ton size, or 48,000 BTU/h: the YCE48B21S belongs to the York YCE (LX) series, the smallest of the 2 sizes we offer in this series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.
The YCE is a York LX R-410A condensing unit with a single-stage scroll compressor, which we offer in 4 and 5 tons only, on clearance. It suits replacing a large R-410A condensing unit on a compatible coil, with a G90-equivalent steel cabinet tested in salt spray.
The right size for your home
This size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. We always check the furnace airflow and the size of the return ducts before recommending this size.
The numbers for this size
The spec sheet lists a sound power of 75 dBA. Electrical: 208/230 V single-phase circuit, 25.7 A minimum ampacity, 45 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 4.94 lb (2.24 kg) of R-410A, which our technicians adjust to the actual piping length.
The cabinet measures 35 1/4 x 31 3/4 in at the base and 33 1/4 in high, with an operating weight of 200 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).
Running on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.
It cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.
Same size, other series: York YXV Affinity, York YC2E LX, York YCG LX.
Installation by AirGreen
A Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.
- Free visit: we measure and check the panel and the ducts;
- Written quote, with the planned indoor section and electrical circuit;
- Installing the condensing unit on a level base, and the indoor section;
- Connecting the piping with a 7/8 in vapor valve, evacuation and charge adjusted to the actual length;
- Electrical hookup, full test run and a walk-through of how it works.
The manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: Montreal, Laval, Longueuil, the North Shore and the South Shore.
Let's talk about your home
Ask for a free estimate: we confirm whether 4 tons is the right size, check the panel and the ducts, then give you a written quote. Financing is available.
The outdoor half of a 4-ton central air system
The YCE48B21S sits outside and rejects the heat removed from the house. Indoors it needs a matched section: a coil on top of an electric furnace, or a fan coil.
- Large multi-storey houses cooled through a single duct system
- Open-plan and heavily glazed houses
- Replacing a central air conditioner of the same size
- Large-capacity electric furnace or fan coil
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Cooling only: the unit does not heat. Sold alone: not eligible for the LogisVert grant.
- The indoor section (coil or fan coil) is not included: we choose it from the matches the manufacturer publishes.
- 208/230 V single-phase, 60 Hz circuit: 25.7 A minimum ampacity, 45 A maximum time-delay fuse or breaker.
- Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient control kit extends it to 20°F (-7°C).
- R-410A model: its manufacture and import ended in Canada in 2025; offered while our suppliers' stock lasts.
Explore the range
Central air conditionersSee allSame brand
YORKSee all
Frequently asked questions
Are my ducts big enough for 4 tons?
We always check this at this size. Undersized ducts make the air noisy at the grilles and reduce performance; we assess them during the free estimate.
Does this air conditioner heat the house?
No. The YCE48B21S is cooling only; heating stays with your electric furnace or current system. Sold alone, it is not eligible for the LogisVert grant.
What indoor equipment does it work with?
A cooling coil on top of an electric furnace, or a fan coil. We confirm the match before ordering.
What electrical circuit is needed?
A 208/230 V single-phase circuit with a 25.7 A minimum ampacity and a 45 A maximum time-delay fuse or breaker, according to the manufacturer's spec sheet. We check your panel's capacity before the quote.
What warranty does the manufacturer offer?
According to the manufacturer's spec sheet: 5-year limited parts warranty and 10-year limited compressor warranty. The parts warranty extends to 10 years if the unit is registered online within 90 days of purchase (replacement) or closing (new construction). It does not apply to Internet sales.
A 4-ton central air conditioner, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.