Air Exchanger VENMAR AVS® N SERIES A130E65RS Greater Montreal

In stock
SKU: A130E65RS
119 cfm net1,400 to 2,200 sq ft56% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 119 cfm net, enough to ventilate 1,400 to 2,200 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 119 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
56%
At −25 °CCode: 54% minimum
67%
At 0 °CMeasured at 66 cfm
Net airflowThe ducts cost it 12 cfm
0.2 in · test bench131 cfm
0.4 in · with ducts119 cfm

$29.28

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

30W
Running continuously
263kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code for Greater Montréal. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 56% at 66 cfm.

Airflow and efficiency: manufacturer's published data. Cost: 30 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

DampersMotorized dampers: no backdraft damper to add

The A130E65RT/RS spec sheet lists built-in motorized dampers, so no additional backdraft damper is required. The manual reminds installers not to screw the ducts to the side ports so as not to interfere with those dampers.

120/minVirtuo tunes the motors from 120 readings a minute

Both PMSM motors are controlled by an artificial intelligence taking 120 readings per minute to hold the requested airflow, regardless of weather, stack effect or filter clogging.

56%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 66 cfm.

DamperIt defrosts without depressurizing the house

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

−12 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 131 to 119 cfm. Most spec sheets show only the first number, precisely because it looks better.

30 WMeasured at the airflow it actually runs at

Its 67% at 0 °C is measured at 66 cfm, the continuous airflow of a typical home. At that setting it draws 30 W, or about 263 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years. We register the warranty in your name at commissioning.

5 inWhat it needs on site

5 in ducts, side connection. It needs enough clearance to slide the core out once a year.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
23.78 × 16.14 × 19.12 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
131 cfm
Net airflow at 0.4 in. w.g.
119 cfm
SRE at 0 °C (66 cfm)
67%
SRE at −25 °C (66 cfm)
56%
ASE at 0 °C
71%
Power draw
30 W
Efficacy
2.2 cfm/W
Type
ERV
Connection
Side ports
Duct collars
5 in
Defrost cycle
Recirculation (motorized damper)
Filters
Washable MERV 8 filter and washable exhaust filter included
Dimensions (L × D × H)
23.78 × 16.14 × 19.12 in
Power supply
120 V
Warranty — core
5 years
Warranty — motors
5 years
Warranty — parts
5 years

Airflow and efficiency: manufacturer's published data. Annual consumption calculated at 30 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Introducing the VENMAR AVS® N SERIES™ERV 130 CFM 65% SRE with Virtuo Air Technology™ Side Ports A130E65RS

Welcome to AirGreen, a leading HVAC company based in Montreal. With our vast services covering HVAC sales and installation across Greater Montreal, Laval, Longueuil, South Shore, and North Shore, we are committed to enhancing your indoor environments. On our website, we have a dedicated Air Exchanger section where we offer an extensive range of Venmar Air Exchangers. One such standout product is the VENMAR AVS® N SERIES™ERV 130 CFM 65% SRE with Virtuo Air Technology™ Side Ports A130E65RS.

At the forefront of the industry’s most advanced residential fresh air systems, the VENMAR AVS® N SERIES™ERV A130E65RS is explicitly engineered and refined to simplify contractor operations, increase profitability, and ensure constant superior air quality.

The Power of Virtuo Air Technology™

Thanks to the groundbreaking Virtuo Air Technology™, the unit achieves airflow calibration and auto-balancing swiftly and maintains it throughout the product's life.

  • Integrated LCD screen: Set your desired CFM (from 35 to 130 CFM) using the first-ever integrated LCD screen. Once set, the airflow is automatically configured.
  • Real-Time LCD: It features an integrated electronic airflow measurement device giving real-time LCD readings.
  • Diagnostic Tool: This air exchanger is equipped with an integrated diagnostic tool, simplifying the unit's maintenance and troubleshooting.

Energy-Efficiency

Fitted with PMSM ECM motors, this model guarantees minimal energy consumption. This attribute not only makes it environmentally friendly but also translates to significant cost savings for users over time.

Installation Flexibility

Flexibility is at the heart of the VENMAR AVS® N SERIES™ERV A130E65RS's design. It supports both suspended installation (chains included) and wall-mount installation. The universal brackets included in the package offer a choice of 2 or 4 brackets installation.

Unit Description and Performance

The VENMAR AVS® N SERIES™ERV A130E65RS packs impressive specifications that guarantee optimal performance.

  • SRE Performance: The unit achieves an impressive SRE of 67% at 0°C and 56% at -25°C (66 CFM, 31 L/s), ensuring optimal energy conservation.
  • Port Size: With a port size of 5", the unit accommodates standard installations.
  • Recirculation Defrost: This approach utilizes existing heat, reducing energy costs.
  • Durable Construction: The corrosion-resistant galvanized steel door and cabinet ensure the unit's longevity.
  • Air Leakage Prevention: The one-piece molded insulation shell (expanded polystyrene; UL 94 HF-1 certified) prevents air leakage.
  • Virtuo Constant Airflow and Auto-Balancing Device: Our advanced unit incorporates a patent-pending Virtuo constant airflow and auto-balancing device. Paired with motorized dampers, the unit ensures efficient and balanced ventilation at all times.
  • Maintenance: The unit operates without a drain, simplifying the installation process and reducing maintenance requirements. It can recirculate air within the dwelling with the recirculation mode using a main wall control.
  • Power Cord: The unit comes with a 6' power cord for your convenience.
  • Electrical Specifications: The unit's electrical specs include 120 volts, 60 Hz, 2.4 A, and 110 W.

Core, Filters, and Options

  • Core: The unit features a polypropylene crossflow core with a polymeric membrane and aluminum covers, which are impact-resistant and non-washable.
  • Filters: The unit comes with a standard washable MERV 8 grade filter. An optional MERV13 grade filter (part no. V24285) and an optional HEPA media type filter (part no. V25000) are available.
  • Options: The unit is compatible with the Tandem transition (part no. 14690) and is recommended for installations producing up to 110 CFM only.

Homeshield™ Defrosting System

Our unique Homeshield™ defrosting system ensures no negative pressure is created by air exhausted outdoors as the air is recirculated into the house, helping prevent any backdraft.

Fan Curves with Virtuo Air Technology™

Thanks to Virtuo Air Technology™, there is no need to manually balance the unit. Both PMSM motors are controlled by an artificial intelligence performing 120 readings per minute, then processing this information to maintain the requested airflow. For typical installation, Virtuo will ensure a balanced ventilation at every selected speed, regardless of weather conditions, type of connection, variable speed furnace/AHU, stack effect, filter clogging, and so on.

Compliance with Requirements and Standards

The VENMAR AVS® N SERIES™ERV 130 CFM 65% SRE with Virtuo Air Technology™ Side Ports A130E65RS is UL 1812 compliant (safety), CSA C22.2 No. 113 compliant (safety), can be installed in compliance with CSA F326, performance-tested in accordance with CSA C439 Standard, complies with ROHS 2015/863 directive, and is compliant with Prop 65.

At AirGreen, we are committed to offering a broad range of HVAC products designed for our customers' comfort and wellbeing. Choose AirGreen for an unparalleled HVAC experience.