Durastar 24 V Thermostat Interface – DR24VINT2

In stock

The Durastar interface that lets a standard 24 V thermostat, Nest, Ecobee or Honeywell, run a Durastar mini-split heat pump without giving up inverter operation.

AirGreen codeAG-AC-142

24 Voff-the-shelf thermostat
Inverteroperation preserved
Transformernot included
24 V thermostatGenuine part
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-142
BrandDurastar
Part no.DR24VINT2
ForDurastar DRAW, DRAC, DRAL, DRAF, DRAS and DRAD (F2A series) units
ConnectionSupplied 4-wire cable or 2-wire HA/HB
Dimensions4 × 6-1/8 × 1-1/2 in

The Durastar DR24VINT2 24 V thermostat interface lets a standard 24 V thermostat, such as a Nest, an Ecobee or a Honeywell, run a Durastar mini-split heat pump. Per Durastar, the compressor keeps its variable-speed inverter operation.

The thermostat you already know

When a furnace or an old system is replaced, many customers want to keep their wall thermostat or install a 24 V smart thermostat. The DR24VINT2 makes this possible on a Durastar heat pump, with or without Wi-Fi, without giving up the variable speed that makes an inverter compressor efficient.

Compatibility

Per the Durastar compatibility chart, the interface fits R-454B DRAW, DRAC, DRAL, DRAF, DRAS and DRAD units in the F2A series. In R-410A, it fits the DRAC_F1A, DRAC24F1B, DRAL_F1A, DRAF_F1A and DRAD_F1A, and DRAW_F1B wall units with the DRPDRAWMFB1 adapter; the DRAW_F1A, DRAS12F1A and DRAS12F1B are not compatible. You need one interface per indoor unit.

Connection and power

The interface connects to the indoor unit with the supplied 20 in 4-wire cable or two non-polar HA/HB wires, up to 65 ft. It is powered by the indoor unit; the 24 VAC transformer that powers the thermostat is not included. The white box measures 4 × 6-1/8 × 1-1/2 in and is for indoor installation.

Installed by AirGreen in Greater Montréal

We install it in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with your unit’s model number.

01 · What it is for

Your 24 V thermostat in charge of the Durastar unit

It connects to the indoor unit with the supplied 4-wire cable or two non-polar HA/HB wires, and passes on the thermostat’s calls: heating, cooling, fan and dehumidification.

  • Keeping an existing wall thermostat during a replacement
  • Installing the 24 V smart thermostat chosen by the customer
  • Ducted units run like a central system
  • The same thermostat model in every zone of a building
Nest, Ecobee, HoneywellDurastar lists it for standard 24 VAC thermostats, with or without Wi-Fi.
Inverter preservedThe compressor keeps its variable speed, per Durastar.
One per indoor unitEach unit run by a thermostat gets its own interface.
Compatible with
DRAW_F2ADRAC_F2ADRAL_F2ADRAF_F2ADRAS_F2ADRAD_F2ADRAC_F1ADRAC24F1BDRAL_F1ADRAF_F1ADRAD_F1ADRAW_F1B
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandDurastar
Part no.DR24VINT2
Type24 V thermostat interface
ThermostatsStandard 24 VAC (Nest, Ecobee, Honeywell, etc.), with or without Wi-Fi
R-454B compatibleDRAW, DRAC, DRAL, DRAF, DRAS and DRAD (F2A series)
R-410A compatibleDRAC_F1A, DRAC24F1B, DRAL_F1A, DRAF_F1A, DRAD_F1A; DRAW_F1B with DRPDRAWMFB1
Not compatibleDRAW_F1A, DRAS12F1A, DRAS12F1B
Units per interfaceOne
Inverter operationPreserved
ConnectionSupplied 20 in 4-wire cable, or 2 non-polar HA/HB wires (16 to 20 AWG)
Maximum length65 ft (20 m)
Interface power5 to 12 V, from the indoor unit
Transformer24 VAC for the thermostat, not included
TerminalsR, C, G, Y1, Y/Y2, B, W, W1, E/AUX, DH, L
Ambient temperature32 to 110 °F (0 to 43 °C), indoor use
Dimensions4 × 6-1/8 × 1-1/2 in (100 × 155 × 36 mm)
ColorWhite
Manufacturer sheetDurastar, form V1.0_0625
AirGreen codeAG-AC-142
03 · Before installing

What to know before installing

  • Per the Durastar compatibility chart: R-454B DRAW, DRAC, DRAL, DRAF, DRAS and DRAD (F2A series) units; in R-410A, DRAC_F1A, DRAC24F1B, DRAL_F1A, DRAF_F1A, DRAD_F1A and DRAW_F1B wall units with the DRPDRAWMFB1 adapter. DRAW_F1A, DRAS12F1A and DRAS12F1B are not compatible.
  • One interface per indoor unit: two heads, two interfaces.
  • The interface is powered by the indoor unit (5 to 12 V). The 24 VAC transformer that powers the thermostat is not included.
  • Connection: supplied 20 in 4-wire cable (DRPDRSTATEXT1 extender optional) or two non-polar 16 to 20 AWG wires, up to 65 ft; Durastar recommends 16 AWG stranded shielded wire on new installations.
  • Indoor use only. The Durastar central system with a DRUM air handler already takes a 24 V thermostat per its sheet.
04 · Goes with

You may also need

Same category
Original parts
See all
05 · Questions

Frequently asked questions

Is my unit compatible?

If it is a Durastar R-454B DRAW, DRAC, DRAL, DRAF, DRAS or DRAD unit (F2A series), yes per the Durastar chart. In R-410A, several F1A series are too, but not the DRAW_F1A or the DRAS12F1A and F1B. Send us your model number and we confirm before ordering.

Will my smart thermostat work?

Durastar lists it for standard 24 VAC thermostats such as Nest, Ecobee or Honeywell, with or without Wi-Fi. We check the wiring your model needs before installing.

Do I need a transformer?

Yes, for the thermostat: a 24 VAC transformer, which Durastar does not include. The interface itself is powered by the indoor unit.

I have two heads: how many interfaces?

Two. Durastar plans one interface per indoor unit.

Can you install it?

Yes. We fit the interface and the thermostat, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 24 V thermostat for your Durastar unit

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.