Floor Heating Secondary Module HONEYWELL CT230-GA/U | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: CT230-GA/U

A floor heating thermostat controls a maximum of 15 A.

Thermostat accessoryproduct type
Simpleno app
3 yearsmanufacturer warranty
Get my installed price 514 316-2973

Quick facts

Model numberCT230-GA/U
ProgrammableNo
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty3 years

A floor heating thermostat controls a maximum of 15 A. For a large kitchen, a finished basement or an open-concept area, the heating element may need more. The Honeywell CT230-GA/U, from the Aube line, handles this situation. It's not a thermostat but a secondary module that works under the direction of a TH114-AF or TH115-AF main thermostat in the 12 VDC version. The floor is divided into linked zones: the main thermostat controls its own zone and passes its setpoints to the modules, which each control their own. The occupant sees only one control, and the whole floor heats in a coordinated way.

Extending floor heating beyond 15 A

The CT230-GA/U controls one electric floor heating zone at 120 V or 240 V, with a maximum load of 15 A resistive, or 3,600 W at 240 V or 1,800 W at 120 V. Up to 10 modules can be linked in a single installation, each one able to control 15 A. The main thermostat keeps the settings and programming for the entire floor.

No dial, installable anywhere

The module has no adjustment dial, since all the setpoints come from the main thermostat. It can therefore be installed wherever is most practical for the wiring, without worrying about access for the occupants. An ON/STANDBY switch still lets you put its zone to rest independently, for example during work in part of the room.

Built-in protection

Each CT230-GA/U has its own built-in ground fault protection (GFCI/EGFPD) with a test light. No separate safety cutoff is therefore required for its zone. It carries CSA approval.

Technical specifications

  • Function: secondary module (linked zone) for electric floor heating over 15 A
  • Voltage: 120 VAC or 240 VAC, 60 Hz
  • Maximum load per module: 15 A resistive (3,600 W at 240 V, 1,800 W at 120 V)
  • Up to 10 CT230 modules per installation
  • Compatible with Aube TH114-AF / TH115-AF main thermostats operating at 12 VDC
  • No adjustment dial; test light
  • ON/STANDBY switch to put the zone to rest independently
  • Built-in ground fault protection (GFCI/EGFPD) with test light
  • 6 in. tinned copper connection leads
  • CSA approval
  • Dimensions: 122 x 70 x 23 mm (4.9 x 2.8 x 0.9 in.)
  • Colour: white

Installation and wiring

Each CT230-GA/U module connects to line voltage and to its own portion of the heating element, using 6 in. tinned copper leads. It is linked to the main thermostat, which operates at 12 VDC. Our technicians first plan how the load is split: each zone must not exceed 15 A, or 3,600 W at 240 V or 1,800 W at 120 V. They then shut off the power, verify that no voltage is present, connect the module and the main thermostat, and test each zone individually, including the built-in protection using the TEST button.

What projects it's for

The CT230-GA/U is the answer as soon as the total power of a floor heating system exceeds what one thermostat can control on its own. Typical cases are large kitchens, open-concept areas, finished basements and some commercial spaces. Our advisors calculate the power of the planned heating element and determine how many modules are needed. They also check the compatibility of the chosen main thermostat; in our selection, the TH115-AF-GB/U is listed as compatible with the CT230-GA/U.

Secondary module or second thermostat

You could split a large floor into two circuits controlled by two independent thermostats. The result would be less practical, though: two setpoints to adjust, two schedules to manage and zones that don't always heat at the same pace. With the CT230-GA/U, a single control manages the entire floor, and the main thermostat's programming applies to every zone. It's simpler for the occupant, and the floor heats evenly.

Maintenance and checks

The module needs no routine maintenance. The built-in protection of each module should still be checked periodically using the TEST button. If one zone stays cold while the others heat, first check the position of the ON/STANDBY switch on the corresponding module. If the protection trips, don't keep resetting it: shut off the circuit and contact us to have the heating element checked.

An installation designed for your home

We don't sell a thermostat the way you'd sell a box off a shelf. Every AirGreen recommendation starts from your actual installation: type of equipment, voltage, number of conductors, location of the wall box and your family's habits. As a Montréal family HVAC business active for more than 15 years and holding an RBQ licence, we serve Montréal, Laval, Longueuil, the North Shore and the South Shore. Our technicians arrive with the tools needed to check the circuit, mount the control level, run operating tests and show you the settings that matter. You're left with a clean installation and a thermostat you know how to use. To see the products up close, our Boucherville showroom is open to you.

Call on AirGreen for the sale and professional installation of this model in Montréal, Laval, Longueuil, the North Shore and the South Shore. Tell us what type of equipment needs to be controlled and how many rooms are involved, and we'll suggest a clear solution, installed by our own technicians.

01 · Key facts

Key facts: HONEYWELL CT230-GA/U

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

TypeThermostat accessoryHONEYWELL CT230-GA/U
Power120 VAC or 240 VAC, 60 HzVoltage
Capacity15 A resistiveMaximum load per module
Wi-FiNoconnection
02 · Head to head

The HONEYWELL CT230-GA/U or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

03 · The system

Products that go with the HONEYWELL CT230-GA/U

Parts named in its spec sheet that we sell and install.

04 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01CompatibilityExisting system and thermostat checked before ordering.
  2. 02MountingInstalled in the most representative spot.
  3. 03ConnectionWiring or wireless pairing, depending on the model.
  4. 04SettingsSet-up in the thermostat or the app.
  5. 05TestOperation checked with you.
05 · Specifications

HONEYWELL CT230-GA/U specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralFunctionsecondary module (linked zone) for electric floor heating over 15 A
ElectricalVoltage120 VAC or 240 VAC, 60 Hz
ElectricalMaximum load per module15 A resistive (3600 W at 240 V, 1800 W at 120 V)
GeneralOtherUp to 10 CT230 modules per installation
GeneralOtherCompatible with Aube TH114-AF / TH115-AF main thermostats operating on 12 V DC
GeneralOtherNo adjustment dial; test light
GeneralOtherON/STANDBY switch to put the zone at rest independently
GeneralOtherBuilt-in ground fault protection (GFCI/EGFPD) with test light
GeneralOther6 in. tinned copper lead wires
GeneralOtherCSA certification
Format and contentsDimensions122 x 70 x 23 mm (4.9 x 2.8 x 0.9 in.)
Format and contentsColourwhite
06 · Questions

Frequently asked questions about the HONEYWELL CT230-GA/U

Short answers, no detours.

What is the warranty?

3 years, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)