Zoning Panel HONEYWELL TrueZONE HZ221/U | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: HZ221/U

A multi-storey home heated and cooled by a single central heat pump often has two climates: the ground floor stays cool while the upper floor overheats in summer, and the reverse sometimes happens in winter.

Zoning panelproduct type
Simpleno app
5 yearsmanufacturer warranty
Get my installed price 514 316-2973

Quick facts

Model numberHZ221/U
ProgrammableNo
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty5 years

A multi-storey home heated and cooled by a single central heat pump often has two climates: the ground floor stays cool while the upper floor overheats in summer, and the reverse sometimes happens in winter. The Honeywell TrueZONE HZ221/U zoning panel addresses this by dividing a forced-air system into two independent zones, each controlled by its own thermostat. It's the solution we suggest when a home needs two separate settings without adding a second unit.

Two zones for a heat pump with backup heat

The HZ221 is designed for single-stage heat pump systems with backup heat, meaning one compressor stage in heating and cooling, plus electric or fuel-fired backup heat. That makes it a very good fit for Québec homes where a central heat pump has been added to a forced-air heating unit. For a conventional installation without a heat pump, we generally steer our customers toward the TrueZONE HZ311 or HZ322, and we always verify the exact configuration of your equipment before choosing a panel.

Zoning works like this: motorized dampers are installed in the ducts that supply each zone. Each zone has its own thermostat. When a zone calls for heating or cooling, the panel opens its damper, closes the damper of the satisfied zone and starts the equipment. You get two different temperatures with a single system.

What the panel does day to day

The HZ221 coordinates the calls from both thermostats and handles automatic changeover between heating and cooling. It offers fan control by zone, so air circulation can be requested in just one zone, as well as variable-speed fan control for equipment that has it. An emergency heat switch lets you switch to backup heat only if the compressor has to be taken out of service.

The panel accepts a discharge air temperature sensor. Installed in the supply duct, it monitors the temperature of the air leaving the equipment, which helps protect the system when few dampers are open. The C7735A sensor is not included with the panel alone: it comes in the HZ221K/U kit, which also adds a transformer.

A panel designed for a clean installation

Heavy-duty pressure terminals make it easier to connect the thermostats, dampers and equipment. LED indicators clearly show the status of each zone and each output, which speeds up diagnosis during a service visit. The panel is compact and allows a tidy installation near the unit. A resettable fuse protects the 24 V circuit, so no fuse has to be replaced in the event of a short circuit.

Compatibility

The HZ221 runs on 24 VAC and accepts any 24 V zone thermostat. It pairs with 8 to 14 in. TrueZONE bypass dampers, which relieve excess air when only one zone is calling. The panel is powered by a transformer, for example the AT140A1042/U or the AT175A1008/U. Our technicians choose the transformer based on the number of dampers and the other loads on the circuit.

Our approach to a zoning project

Zoning isn't just about installing a panel. For a two-zone system to work well, the ducts must be able to deliver the airflow each zone needs, the dampers must be properly sized and the bypass must be set correctly. During our visit, we:

  1. examine the duct system and identify which branches supply the upper floor and the ground floor;
  2. check the configuration of the heat pump and its backup heat;
  3. determine where the dampers and the bypass damper go;
  4. choose the two zone thermostats and the location of each one;
  5. install, connect and test each zone in heating and cooling.

You're free to choose the thermostats as long as they're 24 V models compatible with a heat pump and its backup heat. We often recommend two identical models, so the programming is the same from one zone to the other.

Savings and comfort in the cold season

With two zones, you heat the bedroom floor to a lower temperature during the day and the ground floor to a lower temperature at night. The heat pump no longer works to keep the whole house at the same setpoint. In summer, cooling focuses on the upper floor, often the warmest zone. In winter, backup heat is only called on when the heat pump is no longer enough, and the panel manages that transition with the thermostats.

Zoning also improves the balance of the house: less difference between floors, fewer rooms where you add a portable space heater or a portable fan.

Maintaining a zoned system

The panel needs no special maintenance. During the heat pump's annual service, our technicians check the operation of each damper, the LED indicators, the bypass setting and the discharge air sensor reading. Remember to replace the filter regularly: a clogged filter reduces airflow, which matters even more in a zoned system.

Technical specifications

  • Type: zoning panel for forced-air systems
  • Zones: 2
  • Stages: 1-stage heat pump with backup heat (1H/1C compressor + backup)
  • Power: 24 VAC
  • Display: status and diagnostic LED indicators
  • Functions: automatic changeover, fan control by zone, variable-speed fan control, emergency heat switch, resettable fuse
  • Sensor input: discharge air temperature sensor (C7735A, included in the HZ221K/U kit)
  • Connections: pressure terminals
  • Compatible thermostats: any 24 V zone thermostat
  • Compatible accessories: 8 to 14 in. TrueZONE bypass dampers; AT140A1042/U or AT175A1008/U transformers
  • Contents: panel only

Why AirGreen

AirGreen is a family HVAC business that has been designing, installing and servicing heating and cooling systems in the Montréal area for more than 15 years. With an RBQ licence, we know the multi-storey homes and duct systems typical of Québec well. Our Boucherville showroom lets you see the thermostats and equipment before deciding.

For the sale and professional installation of the Honeywell TrueZONE HZ221/U panel and your two-zone system, contact AirGreen. We serve Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · Key facts

Key facts: HONEYWELL TrueZONE HZ221/U

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

TypeZoning panelHONEYWELL TrueZONE HZ221/U
Power24 VACPower supply
Capacitysingle-stage heat pump with backup heatStages
Displaystatus and diagnostic LED indicatorsDisplay
02 · Head to head

The HONEYWELL TrueZONE HZ221/U or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

03 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01CompatibilityExisting system and thermostat checked before ordering.
  2. 02MountingInstalled in the most representative spot.
  3. 03ConnectionWiring or wireless pairing, depending on the model.
  4. 04SettingsSet-up in the thermostat or the app.
  5. 05TestOperation checked with you.
04 · Specifications

HONEYWELL TrueZONE HZ221/U specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralTypezoning panel for forced-air systems
GeneralZones2
GeneralStagessingle-stage heat pump with backup heat (1H/1C compressor + backup)
ElectricalPower supply24 VAC
Format and contentsDisplaystatus and diagnostic LED indicators
GeneralFunctionsautomatic changeover, zone fan control, variable-speed fan control, emergency heat switch, resettable fuse
GeneralProbe inputsupply air temperature probe (C7735A, included in the HZ221K/U kit)
ElectricalConnectionpush-in terminals
GeneralCompatible thermostatsany 24 V zone thermostat
GeneralCompatible accessoriesTrueZONE bypass dampers 8 to 14 in.; AT140A1042/U or AT175A1008/U transformers
Format and contentsContentspanel only
05 · Questions

Frequently asked questions about the HONEYWELL TrueZONE HZ221/U

Short answers, no detours.

What is the warranty?

5 years, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.