Zoning Panel HONEYWELL TrueZONE HZ322/U | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: HZ322/U

Newer equipment increasingly operates in two stages: a furnace that starts at reduced output before moving to full output, a heat pump with two compressor stages, an air conditioner that modulates its effort.

Zoning panelproduct type
WiredRedLINK through the THM4000R adapter
5 yearsmanufacturer warranty
Get my installed price 514 316-2973

Quick facts

Model numberHZ322/U
ProgrammableNo
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty5 years

Newer equipment increasingly runs on two stages. Think of a furnace that starts at reduced output before moving to full output, a heat pump with two compressor stages, an air conditioner that modulates its effort. To zone this kind of system without losing its advantages, you need a panel that can manage these stages. The Honeywell TrueZONE HZ322/U controls up to three zones and up to two heating stages and two cooling stages, with conventional equipment or a heat pump.

It is the panel we choose most often for a mid-sized house equipped with a two-stage unit and zoned by floor.

A zoning panel for two-stage equipment

Like all TrueZONE panels, the HZ322 coordinates motorized dampers installed in the ducts and one thermostat per zone. It does, however, add features that set it apart from its simpler siblings, the HZ221 and the HZ311.

Plain-language installation display

The HZ322 has a digital installation display that shows the settings in plain language. Our technicians use it to configure the equipment type, the number of stages, damper management and temperature limits without going through a series of jumpers or DIP switches. LED indicators complement the display by showing the status of each zone and each output, which makes checks easier during maintenance.

Staging based on supply air temperature

With a supply air temperature sensor connected, the panel can provide staging based on supply air temperature. It monitors the air leaving the equipment and decides when to move to second stage or stay in first. This avoids starting the second stage for a small zone, and improves comfort through gentler cycles. The C7735A sensor comes with the HZ322K/U kit, which also adds a transformer; with the panel alone, we add it to the installation.

Adjustable high limit and emergency heat

The high limit is adjustable from 110 to 180°F, so the protection can be matched to the equipment. For heat pump systems, an emergency heat switch switches the system to backup heat only when necessary. The panel also handles automatic changeover, zoned fan control and variable-speed fan control. A resettable fuse protects the 24 V circuit.

Wired or wireless thermostats

The HZ322 works with wired 24 V thermostats. It can also accept RedLINK wireless thermostats when the THM4000R1000 wireless adapter (sold separately) is added. This option is useful in a finished house where running a new wire to a zone would be difficult: the thermostat for that zone then communicates wirelessly with the panel.

Installation and commissioning by AirGreen

A two-stage zoned system takes a little more thought than a single-stage one. We look at the airflow each zone can receive, the equipment's first-stage capacity and how the bypass damper should be set. Our approach:

  1. Analysis of the existing or planned equipment: furnace, air conditioner or heat pump, number of stages.
  2. Division of the house into two or three zones based on use and sun exposure.
  3. Installation of the zone dampers and the bypass damper in the ducts.
  4. Installation of the thermostats, wired or RedLINK with adapter.
  5. Panel setup on the installation display, then a complete test of each zone and each stage.

Comfort and savings in the Québec climate

A two-stage unit spends most of the winter in first stage, which is gentler and more economical. Zoning reinforces this advantage: when only one zone calls for heat, the panel can stay in first stage, and each zone stays at the temperature that suits it. Bedrooms can be cooler during the day, the basement can stay at a moderate setpoint, and the living areas stay comfortable in the evening.

With a heat pump, backup heat only comes on when the heat pump is no longer enough, which is particularly useful during long cold spells. In summer, cooling is concentrated upstairs without needlessly cooling the basement.

Comparison with the other TrueZONE panels

The HZ221 is limited to two zones and a single-stage heat pump with backup heat. The HZ311 offers three zones but only for single-stage conventional equipment. The HZ322 combines three zones, two stages, heat pump or conventional, and an installation display. Finally, the HZ432 accepts up to four expandable zones and advanced dual energy. For most multi-storey homes equipped with a modern two-stage unit, the HZ322 strikes a very good balance.

Maintenance

During annual maintenance, we check the dampers, the supply air sensor, the saved settings and the bypass. On your side, replace the filter at the recommended intervals and keep the supply and return grilles clear.

Technical specifications

  • Type: zoning panel for forced-air systems
  • Zones: up to 3
  • Stages: up to 2 heating / 2 cooling, conventional or heat pump
  • Power: 24 VAC
  • Display: plain-language digital installation display and status LEDs
  • Features: staging based on supply air temperature, automatic changeover, zoned fan control, variable-speed fan control, emergency heat switch, resettable fuse
  • High limit: adjustable, 110 to 180°F
  • Sensor input: supply air temperature sensor (C7735A, included in the HZ322K/U kit)
  • Wireless: RedLINK compatible with the THM4000R1000 adapter (optional)
  • Connections: pressure-type terminals
  • Compatibility: 24 V and RedLINK thermostats (with adapter), TrueZONE dampers
  • Contents: panel only

Why choose AirGreen

For more than 15 years, AirGreen has been designing and installing residential HVAC systems in the Montréal area. As a family business holding an RBQ licence, we install the furnaces, heat pumps and air conditioners that we then zone, which lets us set up the panel for the actual equipment. Our showroom in Boucherville welcomes you to see the thermostats and discuss your project.

For the sale and professional installation of the Honeywell TrueZONE HZ322/U panel, contact AirGreen. We serve Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · Key facts

Key facts: HONEYWELL TrueZONE HZ322/U

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

TypeZoning panelHONEYWELL TrueZONE HZ322/U
For24 V and RedLINK thermostatsCompatibility
Power24 VACPower supply
Capacityup to 2 heat / 2 cool, conventional or heat pumpStages
02 · Head to head

The HONEYWELL TrueZONE HZ322/U or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

03 · The system

Products that go with the HONEYWELL TrueZONE HZ322/U

Parts named in its spec sheet that we sell and install.

04 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01CompatibilityExisting system and thermostat checked before ordering.
  2. 02MountingInstalled in the most representative spot.
  3. 03ConnectionWiring or wireless pairing, depending on the model.
  4. 04SettingsSet-up in the thermostat or the app.
  5. 05TestOperation checked with you.
05 · Specifications

HONEYWELL TrueZONE HZ322/U specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralTypezoning panel for forced-air systems
GeneralZonesup to 3
GeneralStagesup to 2 heat / 2 cool, conventional or heat pump
ElectricalPower supply24 VAC
Format and contentsDisplayplain-language digital installation display and status LED indicators
GeneralFunctionssupply air temperature staging, automatic changeover, zone fan control, variable-speed fan control, emergency heat switch, resettable fuse
GeneralHigh limitadjustable, 110 to 180 °F
GeneralProbe inputsupply air temperature probe (C7735A, included in the HZ322K/U kit)
ElectricalWirelessRedLINK compatible with the THM4000R1000 adapter (optional)
ElectricalConnectionpush-in terminals
GeneralCompatibility24 V and RedLINK thermostats (with adapter), TrueZONE dampers
Format and contentsContentspanel only
06 · Questions

Frequently asked questions about the HONEYWELL TrueZONE HZ322/U

Short answers, no detours.

What does the HONEYWELL TrueZONE HZ322/U work with?

According to the manufacturer’s sheet: 24 V and RedLINK thermostats (with adapter), TrueZONE dampers.

What is the warranty?

5 years, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.