PTAC: Friedrich | Heat Pump 15,000 BTU | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: PDH15K5SG
14,500 BTU/h actual≈ 225 to 330 sq ftHeat pump + 5 kW max
Talk to an HVAC technician · 514 316-2973
Heat pump and a heater of up to 5 kWStandard 42 × 16 in sleeve6-year compressor warranty
01 · Your room

Is it the right size for this room?

Friedrich doesn't publish a room size for this unit. From its 14,500 BTU/h of cooling, we estimate ≈ 225 to 330 sq ft. Choose your room's area.

It's the right size.

For a 225 to 280 sq ft room, this is the range we estimate for this unit: 14,500 BTU/h of cooling, 13,300 BTU/h of heat-pump heating and a heater of up to 5,000 W when the cold calls for it.

AirGreen estimate: Friedrich publishes no room size for its PTACs, so this range is a guide based on cooling capacity. Our estimator confirms the exact area on site.

02 · Performance

What it does, in numbers

14,500BTU/h
Cooling at 230 V14,200 at 208 V, the supply in many buildings.
13,300BTU/h
Heat-pump heatingRated at 8 °C (47 °F).
5,000W
Maximum electric heater4,089 W at 208 V. It heats when the heat pump can no longer keep up.
10.4EER
Cooling efficiencyThat's 1,394 W drawn at 230 V for 14,500 BTU/h.
What it costs per yearTypical 278 sq ft room · Rate D
Summer · cooling

$31.06

Cooling, all summer

Less than a 60 W light bulb

Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.

Winter · heating

≈$205

Heating, all winter

≈ $15 less than baseboard heaters

Heat pump8 °C and warmer outside · 10% of the heat≈ $7
Electric heaterBelow 8 °C · 90% of the heat≈ $198

Typical 278 sq ft room with one exterior wall, in Montréal: 1,982 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Friedrich rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.

≈ $236 for the year, before tax. Winter is 87% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $19.70.

$0.16/h
One hour of cooling
$0.14/h
One hour of heat-pump heating
$0.56/h
One hour on the 5 kW heater

Capacities and currents: Friedrich ZoneAire Premier product profile PP_PTACPRE_2023 (rev. 2-20-23) and installation manual 9830 1000_00. Power draw: 1,394 W in cooling (14,500 BTU/h ÷ EER 10.4), 1,255 W in heat-pump mode, 5,000 W on the 5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

14,500What it really delivers in cooling

The name says 15,000 BTU: that's the unit's size class. Friedrich publishes 14,500 BTU/h at 230 V, and 14,200 at 208 V, the supply in many buildings.

5,000 WThe heater that takes over

The "5" in PDH15K5SG sets the heater at 5.0 kW: 5,000 W and 17,000 BTU/h at 230 V, 4,089 W at 208 V, on a 6-30P plug and a 30 A circuit. It heats when the heat pump can no longer keep up.

3.1The COP published at 8 °C

Friedrich publishes a heat-pump COP of 3.1: 13,300 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.1 in heat, against 1 for the heater or a baseboard.

10,530What it still heats at 3 °C outside

At 37 °F (3 °C) outside, Friedrich still publishes 10,530 BTU/h of heat-pump heating for this model, against 13,300 at 47 °F (8 °C). Output drops with the cold, but the heat pump keeps working.

−1 °CWhen the heat pump steps aside

According to Friedrich's installation manual, the compressor stops when the outdoor coil stays below about 30 °F (−1 °C); the heater then works alone, and the heat pump restarts once the coil warms up.

3.1Pints of water it removes per hour

The dehumidification Friedrich publishes in cooling mode: 3.1 US pints per hour. It's what keeps a room comfortable in summer without it turning clammy.

75 cfmFresh air through the vent door

The vent door brings in up to 75 cfm of outside air, according to Friedrich. Close it to keep all the heat or the cool air in the room.

6-30PThe plug it needs

This model's NEMA 6-30P plug goes into a 6-30R outlet on a dedicated 30 A circuit. In a replacement, we first check the outlet and breaker already in place.

Replacement

It fits a standard PTAC sleeve, with no baffle kit

Friedrich designs this PTAC for the standard 42 × 16 in sleeve, without the added cost of a baffle kit. Our estimator checks the sleeve and the grille in place before ordering.

42 × 16
inches, standard size
04 · Installation

What it needs on site

42 × 16 in sleeveIndustry-standard size
13 ¾ in sleeve21 ½ in with the front
Dedicated 30 A circuitFor the 5.0 kW heater (NEMA 6-30P plug)
124 lbUnit weight

In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.

Complete spec sheetData and cited sources
Model
PDH15K5SG
Cooling capacity (208/230 V)
14,200 / 14,500 BTU/h
Heating capacity, heat pump (208/230 V)
13,000 / 13,300 BTU/h
Electric heater
5.0 kW (4,089 / 5,000 W at 208/230 V)
EER
10.4
COP (heat pump, 47 °F / 8.3 °C)
3.1
Current — cooling (208/230 V)
6.7 / 6.2 A
Current — heat-pump heating (208/230 V)
6.7 / 6.2 A
Power — cooling (230 V)
1,390 W
Power — heat pump (230 V)
1,255 W
Airflow (low/high)
325 / 400 cfm
Dehumidification
3.1 US pints/h
Application range
AirGreen guide ≈ 225 to 330 sq ft (based on capacity); room size confirmed on site
Dimensions
42 × 21 ½ × 16 in (W × D × H, with front)
Sleeve
42 × 16 × 13 ¾ in
Net weight
124 lb
Refrigerant
R-410A · 39 oz
Heat pump → heater
outdoor coil below about 30 °F (−1 °C), per the installation manual
Power supply
208/230 V · 1 ph · 60 Hz

All values: Friedrich ZoneAire Premier product profile PP_PTACPRE_2023 (rev. 2-20-23) and installation manual 9830 1000_00. Operating cost: cooling at 1,394 W for 200 h per summer; heating estimated for a typical 278 sq ft room (1,982 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The neighbouring models

Talk to an HVAC technician before you choose

We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.

Friedrich PTAC PDH15K5SG: 15,000 BTU heat pump with a 5.0 kW backup heater

The PDH15K5SG is a packaged terminal unit (PTAC) from the ZoneAire Premier series: it slides into a 42 × 16 in wall sleeve in the outside wall, and the whole system sits inside the unit. No outdoor unit, no refrigerant piping on site, and every room keeps its own thermostat.

Its edge: it is the most powerful of our PTAC heat pumps, and the only one in that series with a 5.0 kW heater, or 17,000 BTU/h at 230 V for the coldest days. It needs a 30 A circuit.

What sets it apart

  • 14,500 BTU/h of cooling at 230 V (14,200 at 208 V), 15,000 BTU class, with an EER of 10.4.
  • 13,300 BTU/h of heat-pump heat at 230 V (13,000 at 208 V), rated by Friedrich at 47 °F outside, with a COP of 3.1.
  • 5.0 kW heater (5,000 W at 230 V, 4,089 W at 208 V) that takes over when it is too cold for the heat pump.
  • 400 CFM of airflow on high (325 on low), and 3.1 US pints of water removed per hour in cooling.
  • Room freeze protection (factory setting): if the room drops to 40 °F (about 4 °C), even with the unit switched off, it runs the fan and the heater up to 46 °F (about 8 °C).
  • Digital temperature readout and one-touch operation.

Which room it suits

Friedrich publishes no room size for its PTACs: the tool on this page gives an AirGreen guide based on capacity, and AirGreen confirms the size with an on-site assessment of your heating and cooling needs. Smaller room: PDH12K3SG. Same size, cooling with electric heat: PDE15K5SG.

Installed by AirGreen

Our refrigeration technicians and electricians, under AirGreen’s RBQ licence 5645-9605-01 (subclasses 15.10 and 16), set the unit in a standard 42 × 16 in sleeve, with no baffle kit, and plug it in (cord PXPC23030, NEMA 6-30P plug) to a 6-30R outlet on a dedicated 30 A circuit. For a replacement, we check the sleeve and grille in place before ordering.

Warranty: 6 years on the compressor, 6 years on parts and 6 years on labour. Friedrich’s published limited warranty for units sold after September 30, 2026 is 2 years on parts and labour, and 5 years on the sealed system, parts and labour.

Sold and installed by AirGreen. Free on-site estimate anywhere in Montreal, Laval, Longueuil, the South Shore and the North Shore: 514 316-2973.