Temperature Controller HONEYWELL Remote Bulb T678A1353 | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: T678A1353

Not every temperature controller goes on a living room wall.

Thermostat accessoryproduct type
Simpleno app
1 yearmanufacturer warranty
Get my installed price 514 316-2973

Quick facts

Model numberT678A1353
ProgrammableNo
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty1 year

Not every temperature controller goes on a living room wall. In a mechanical room, on a return air duct, near a tank or a boiler, you often need to measure the temperature of a fluid in one place and put the control in another. The Honeywell T678A1353 is a rugged mechanical remote bulb temperature controller, designed for exactly that role. It is not a room thermostat: it is a control device for commercial and institutional HVAC systems.

How the remote bulb works

A 1/2 x 4-3/16 in. copper bulb is placed in the medium to be monitored: the air in a duct, the water in a pipe or a tank. It is connected to the controller housing by a 5 ft capillary tube. The housing itself can be installed in an accessible spot, away from the heat or humidity of the medium being measured. That is what lets you adjust and check the device without working directly on the duct or the piping.

The controller covers a range of 55 to 175 °F (13 to 79 °C), with a maximum bulb temperature of 200 °F. Its 1 °F differential provides tight control. The housing mounts in any position and is ambient temperature compensated, so the temperature of the mechanical room has little effect on the reading.

Two switching stages

The T678A1353 has two SPDT switches, giving two control stages. Each switch can open or close a circuit depending on the temperature: first heating stage, then the second; opening a damper, then starting a piece of equipment; or any other sequence suited to the installation. It operates at 120, 240 or 277 VAC, 50/60 Hz, with a maximum connected load of 2000 VA.

Typical applications

This controller operates dampers and valves in heating, cooling and heating-cooling systems. It is used to regulate the temperature of air or liquid in ducts, pipes, tanks and boilers. Its fast response in return air ducts makes it a popular choice for monitoring the return temperature of an air system. In a commercial building, it can, for example, control an outdoor air damper based on the return air temperature, or operate a valve on a hot water loop.

Installation and adjustment by AirGreen

Installing a bulb controller means positioning the bulb correctly, protecting the capillary and wiring both stages properly. Our technicians:

  1. analyze the application: medium measured, temperature range, equipment to be controlled;
  2. position the bulb in the duct, the well or the tank, where the reading is representative;
  3. route the 5 ft capillary with no tight bends and no contact with sharp edges;
  4. mount the housing in an accessible spot, in the position that works best;
  5. connect the SPDT switches to the dampers, valves or equipment, respecting the voltage and the maximum load;
  6. adjust the setpoints and check that each stage operates correctly.

Choosing the setpoints

A two-stage controller is adjusted according to the desired sequence. For a heating application, the first stage is often set to the target temperature and the second slightly lower, so it only comes in if the first is not enough. For a cooling or ventilation application, the logic is reversed. Our technicians work out with you the sequence that suits your equipment, then record the settings to make future checks easier. The 1 °F differential allows precise control, but the equipment's capacity has to be taken into account to avoid short cycling.

Who it is for

The T678A1353 is meant for managers of commercial, institutional and industrial buildings, owners of buildings with a boiler room and businesses that operate air or water systems. It is found in mechanical rooms, on duct networks and near boilers. To control the temperature of an occupied room, we recommend a room thermostat instead, electronic or smart, which we can also offer and install.

Reliability and savings

A properly adjusted mechanical controller is highly reliable: no software, no batteries, direct and simple control. By keeping the air or water temperature at the right level, it prevents a damper from staying open needlessly or a hot water loop from being kept too hot. During a Québec winter, these adjustments add up to better control of the energy the building uses.

Maintenance

During the annual service, we check the condition of the capillary, how the bulb is secured, the operation of each switch and the accuracy of the setpoints. Avoid bending or crushing the capillary, which is the most delicate part of the device. If the bulb is installed in a tank or a well, make sure it stays in good contact with the medium being measured.

Technical specifications

  • Type: remote bulb temperature controller (mechanical)
  • Stages: 2 (2 SPDT switches)
  • Setting range: 55 to 175 °F (13 to 79 °C); maximum bulb temperature 200 °F
  • Differential: 1 °F
  • Power supply: 120 / 240 / 277 VAC, 50/60 Hz
  • Maximum connected load: 2000 VA
  • Sensing element: 1/2 x 4-3/16 in. copper bulb, 5 ft capillary
  • Mounting: any position; ambient temperature compensated
  • Applications: air or liquid in ducts, pipes, tanks and boilers; dampers and valves in heating, cooling and heating-cooling; fast response in return ducts

Why AirGreen

AirGreen is a family HVAC business holding an RBQ licence that has been installing and servicing residential and commercial systems in the Montréal area for more than 15 years. Our technicians know mechanical controls as well as smart thermostats. Our showroom is in Boucherville.

To buy the Honeywell T678A1353 controller and have it professionally installed, contact AirGreen. We serve Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · Key facts

Key facts: HONEYWELL Remote Bulb T678A1353

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

TypeThermostat accessoryHONEYWELL Remote Bulb T678A1353
Power120 / 240 / 277 VAC, 50/60 HzPower supply
Connectionair or liquid in ducts, pipes, tanks and boilersApps
Capacity2Stages
02 · Head to head

The HONEYWELL Remote Bulb T678A1353 or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

03 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01CompatibilityExisting system and thermostat checked before ordering.
  2. 02MountingInstalled in the most representative spot.
  3. 03ConnectionWiring or wireless pairing, depending on the model.
  4. 04SettingsSet-up in the thermostat or the app.
  5. 05TestOperation checked with you.
04 · Specifications

HONEYWELL Remote Bulb T678A1353 specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralTyperemote bulb temperature controller (mechanical)
GeneralStages2 (2 SPDT switches)
GeneralAdjustment range55 to 175 °F (13 to 79 °C); maximum bulb temperature 200 °F
GeneralDifferential1 °F
ElectricalPower supply120 / 240 / 277 VAC, 50/60 Hz
ElectricalMaximum connected load2000 VA
GeneralSensing element1/2 x 4-3/16 in. copper bulb, 5 ft capillary
Format and contentsMountingany position; compensated for ambient temperature
ConnectivityAppsair or liquid in ducts, pipes, tanks and boilers; dampers and valves in heating, cooling and heating-cooling; fast response in return ducts
05 · Questions

Frequently asked questions about the HONEYWELL Remote Bulb T678A1353

Short answers, no detours.

What is the warranty?

1 year, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.