CANAIR CEB-36MX1421 Evaporator A-Coil | 3 Tons

In stock

The Canair CEB-36MX1421 3-ton R-454B cased coil sits on your furnace and, matched with the Canair 4CDH2030C21 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCEB-36MX1421

3 tons36,000 BTU/h nominal
14-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 216621489
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCEB-36MX1421
ManufacturerCanair
Size3 tons
Width14-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unit4CDH2030C21

Canair CEB-36MX1421: three tons in a narrow 14-1/2 in cabinet, with a single certified pairing

Here is a 3-ton (36,000 BTU/h) coil that does not take up much width. The CEB-36MX1421 is a cased evaporator A-coil from the Canair CEB range, using R-454B refrigerant. It measures 14-1/2 in wide, 24 in high and 21 in deep. It is meant for homes that need a mid-range capacity but have a narrow furnace.

Three measurements that decide everything

Before we talk about brand or price, we take three readings at your home.

  1. The width of the furnace cabinet, to compare with the coil's 14-1/2 in.
  2. The free space above the furnace, because the coil is 24 in high.
  3. The airflow the blower can actually deliver.

If the first two measurements match, installation is straightforward. If the width differs, we build an insulated transition at the visit. If there is not enough height, a duct sometimes has to be moved: better to know before you sign.

A large size on a compact cabinet: why it works

The A shape stretches the coil upward rather than sideways. Two sloped faces meet at the top and the furnace air passes through both. In exchange, the 24 in height is greater than that of the 2-ton coils in the series. If your plenum is low, we take that into account from the technical visit.

The insulated cabinet comes with the coil. It saves having to improvise an enclosure and limits air leaks around the heat exchanger.

A single outdoor unit for this model

Canair publishes a single certified system for the CEB-36MX1421:

  • outdoor unit 4CDH2030C21, AHRI 216621489;
  • cooling 30,000 BTU/h, heating 30,000 BTU/h at 47 °F;
  • SEER2 15.3, HSPF2 9.3.

The 4CDH20 heat pump uses R-454B and has a variable-speed compressor. There is therefore no trade-off between two outdoor units: the choice comes down to the coil width and the capacity of the house.

Reading the ratings without getting confused

A coil has no efficiency of its own. The ratings you see, SEER2 15.3 and HSPF2 9.3, describe the paired system, linked by its AHRI number. That number lets you compare two quotes from two contractors on equal terms.

Canair states that all CEB and 4CDH20 pairings are ENERGY STAR cold climate certified, in Canada and in the United States. Heating capacity at -8.3 °C ranges from 15,200 to 37,800 BTU/h depending on the pairing in the series.

3 tons in 14-1/2 in, 17-1/2 in or 21 in: how to decide

There are three 3-ton coils in the series, with the same R-454B refrigerant and the same TXV expansion valve. They differ only in width, and therefore in the furnace they fit.

  • CEB-36MX1421 (this model): 14-1/2 in, paired with the 4CDH2030C21;
  • CEB-36MX1721: 17-1/2 in, same 4CDH2030C21 outdoor unit family;
  • CEB-36MX2121: 21 in, also with the 4CDH2030C21.

If your furnace cabinet is narrow, stay with this one. Choosing a coil wider than necessary does not add capacity: the nominal size stays at 3 tons in all three cases.

And smaller or larger?

The 2-ton models (CEB-24MX1421 in 14-1/2 in and CEB-24MX1721 in 17-1/2 in) are paired with 4CDH2018C21 units, and the 5-ton models (CEB-60MX2121 in 21 in and CEB-60MX2421 in 24-1/2 in) with 4CDH2048C21 or 4CDH2060C21 units. Three tons suit bungalows and cottages across Greater Montreal, in Laval as in Longueuil. Our load calculation confirms or corrects this starting point.

What the heat pump brings to your heating

In an "add-on" configuration, the furnace keeps its blower, its filters and its role as backup. The heat pump does most of the work as long as it is not too cold; the furnace takes over below a threshold set with you. An electric furnace produces only one unit of heat per unit of electricity, whereas a heat pump delivers two to three times more in mild weather.

In summer, the chain runs the same way in reverse: the refrigerant picks up heat from the air, the condensed water is carried off by the drain, and rooms stay drier than with a window unit.

A word on noise, the filter and maintenance

The coil itself makes no noise: it has no moving parts. What you hear in the house is the furnace blower. A clean filter helps that blower push air freely through both faces of the coil. A clogged filter reduces airflow, which hurts comfort and system performance in summer and winter alike.

We recommend checking the filter at every change of season and calling us if water appears around the furnace: that usually points to a condensate drain that needs cleaning, nothing more.

Quick spec sheet

  • type: cased evaporator coil;
  • size: 3 tons (36,000 BTU/h);
  • refrigerant: R-454B;
  • expansion: TXV;
  • positions: multi-position;
  • dimensions (W × H × D): 14-1/2 × 24 × 21 in;
  • manufacturer warranty: residential, 10 years on the compressor and 10 years on parts; commercial, 5 years and 1 year; 10-year limited labour warranty available as an option.

How the visit and installation unfold

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work falls under RBQ licence 5645-9605-01. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore. The job goes like this:

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the coil in the plenum, sealing the connections and adding a transition if needed;
  • outdoor unit on a pad or bracket, brazed piping, nitrogen test, evacuation;
  • condensate drain and thermostat;
  • commissioning, airflow adjustment, explanations.

To confirm before ordering

  • R-454B is paired with an outdoor unit that uses the same refrigerant, installed at the same time.
  • The ratings apply to the certified pairing, not to the coil alone.
  • The furnace must offer the right width, free height and blower.

The Canair brand

Canair is a brand distributed in Quebec by Descair. Its 4CDH20 heat pump on R-454B is paired with CEB cased coils, while the MCPM and MAC coils, on R-410A, serve the previous generation of systems.

LogisVert incentive

The paired Canair system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation; we verify it on the official list when we prepare the quote and put the application together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Canair system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CEB-36MX1421 sits in the plenum of a furnace or air handler. Connected to the Canair 4CDH2030C21 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Canair 4CDH2030C21 outdoor unit
Certified systemMatched with the 4CDH2030C21, the system carries AHRI 216621489.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerCanair
ModelCEB-36MX1421
TypeCased evaporator coil
LineCEB
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Dimensions W × H × D14-1/2 × 24 × 21 in
Matched outdoor unit4CDH2030C21
System AHRI number216621489
System SEER2 / HSPF215.3 / 9.3
Model numberCEB-36MX1421
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 14-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
CANAIR
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Canair coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.