GOODMAN CAUTA3626C3 Evaporator A-Coil | 2 to 3 Tons
The Goodman CAUTA3626C3 2 to 3-ton R-32 uncased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAUTA3626C3
514 316-2973 · sales@airgreen.ca
Quick facts
CAUTA3626C3: choosing the right tonnage, 2 to 3 tons, for a 20 in furnace
People often assume bigger means better. In central air conditioning, the opposite happens all too often: an oversized system shuts off before it has dried the air, and the house stays clammy. The Goodman CAUTA3626C3 evaporator coil serves a specific need: a nominal capacity of 2 to 3 tons (36,000 BTU/h), 20 in wide, using R-32. This page helps you judge whether it is the right size for you.
First, the logic of tonnage
A system's capacity should follow the needs of the house, not the salesperson's whim. A well-insulated home with few south-facing windows needs less than a home with a poorly insulated roof. That is why we do a load calculation before proposing a model.
The 2 to 3 ton size sits in the middle of the series. It suits many bungalows and cottages, especially those where the insulation has been redone and the basement is partly finished.
What an oversized system really costs
- Cycles that are too short: the air cools quickly but stays humid.
- Faster wear on the components that start and stop constantly.
- A higher purchase price, with no gain in comfort.
An undersized system has its own drawbacks, of course: it struggles during heat waves. The load calculation looks for the balance between the two.
Why the C3: the 20 in width
In this series, the C suffix in the model number corresponds to a 20 in width. That is a common dimension for residential furnaces. The coil goes into the plenum, or into a cabinet built on site since it is supplied uncased. If your furnace is a different width, we build an insulated transition when needed.
The A shape provides two sloped faces that meet at the top, and the TXV metering device adjusts the refrigerant flow to demand. The published installation positions are upflow or downflow.
Placing the CAUTA3626C3 on the series scale
Here is how to get your bearings:
- CAUTA3026C3: also 20 in, but 1.5 to 2.5 tons. One step smaller.
- CAUTA3626B3: the same 2 to 3 ton capacity, in 16-1/2 in for a slim furnace.
- CAUTA4230C3: also 20 in, but 2.5 to 3.5 tons. One step larger.
- CAUTA6030C3: 20 in, 3.5 to 5 tons.
- CAUTA3026B3, CAUTA4230D3 and CAUTA6030D3 round out the series in 16-1/2 in or 23-1/2 in.
At home, width and tonnage are settled separately. Once the width is known, you still have to choose the capacity: that is where the load calculation comes in.
The coil, the outdoor unit and the AHRI number
The coil has no efficiency rating on its own. The SEER2, EER2 and HSPF2 ratings belong to the certified set. It is the AHRI number that links a specific coil to a specific outdoor unit. We confirm that match before buying, so that the ratings promised are the ones you get.
A useful point: at our last check, no R-32 match with this coil was listed with ENERGY STAR. We tell you what the AHRI directory says for the outdoor unit selected.
CAUTA3626C3 specifications
- Manufacturer: Goodman;
- Type: uncased evaporator coil;
- Nominal size: 2 to 3 tons (36,000 BTU/h);
- Refrigerant: R-32;
- Width: 20 in;
- Liquid connection: 3/8 in; suction connection: 7/8 in;
- Metering device: TXV;
- Leak detection: R-32 refrigerant sensor designed to last the life of the coil;
- Warranty: 10-year limited parts warranty, online registration within 60 days (not required in Quebec).
The furnace is still useful
With a heat pump as the outdoor unit, the furnace keeps its blower, its filters and its role as backup heat. It takes over below the temperature threshold we set with you. It does not disappear from the picture; it simply moves from the lead role to a supporting one.
How a project with AirGreen unfolds
A family-run heating and cooling company based in Montreal for more than fifteen years, AirGreen carries out its refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01. We work in Montreal, Laval, Longueuil, the North Shore and the South Shore, with the following steps:
- measuring the furnace, checking the blower and the electrical panel;
- fitting the coil and sealing the duct connections;
- installing the outdoor unit, brazed piping, nitrogen pressure test and vacuum;
- connecting the drain and the thermostat;
- commissioning, airflow adjustment and explanations.
Can you keep your current air conditioner?
Generally, no: the R-32 coil has to connect to the outdoor unit the manufacturer intends. We install the complete system.
To check before choosing
- Do the coil and the outdoor unit share the same refrigerant?
- Does the certified match correspond to what you are being offered?
- Does the furnace blower deliver the system's airflow?
Incentives
Hydro-Québec programs apply to the complete system, depending on the installation date, and not to the coil alone. We check the official list at the time of the quote.
When a heat pump takes over the heating
The Quebec winter sets its own rules. A heat pump moves heat from the outdoor air to the inside, and its output drops as the temperature falls. That is why we don't remove the furnace: it becomes the complement that takes over on the coldest days. We set the switchover threshold with you, based on your comfort and your electricity bill.
This division of labour has a concrete advantage: you don't need to oversize the heat pump to cover the cold peak. The system stays a reasonable size, and the furnace handles the few extreme days.
What we can't promise
We won't announce a precise dollar saving before we have seen your house, your ducts and your habits. Those figures depend on too many factors: insulation, the thermostat, the way you use the rooms. What we can give you is a clear quote, a certified match and an installation done by the book.
A simple step to extend the life of the system
Regularly clear the area around the outdoor unit of snow, leaves and branches. Air has to flow freely around it, and it is maintenance you can do yourself without tools. For the rest, the filter, the drain and the connections are part of an annual visit from us.
How to compare two quotes
Place the two documents side by side. Look for the exact name of the coil, the name of the outdoor unit, the AHRI number of the match and the list of work. If even one of these items is missing on one side, you are not comparing two equivalent offers.
We are comfortable with that comparison: our written quote is designed to be read, line by line, by someone who is not in the trade.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CAUTA3626C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 20 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2 to 3-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.