KINGHOME KCAC24FI Evaporator A-Coil | 2 Tons

In stock

The Kinghome KCAC24FI 2-ton R-32 cased coil sits on your furnace and, matched with the Kinghome KU36UXO outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberKCAC24FI

2 tons24,000 BTU/h nominal
17-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedAHRI 218046860
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberKCAC24FI
ManufacturerKinghome
Size2 tons
Width17-1/2 in
RefrigerantR-32
MeteringEEV
Outdoor unitKU36UXO

KCAC24FI: the 2-ton Kinghome evaporator coil for a small home's furnace

Do you have a compact bungalow, a townhouse or a plex unit with its own furnace, and are you thinking about a central heat pump? The Kinghome KCAC24FI is made for that kind of building. It is a cased evaporator coil with a nominal size of 2 tons (24,000 BTU/h), it runs on R-32, and it pairs with the Kinghome KU36UXO outdoor unit.

AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. This page explains what this coil does, which homes it suits and what we check before ordering anything.

Who a 2-ton coil is for

The smallest size in the series serves homes with little air volume to treat: a brick semi-detached house, a bungalow from the seventies with an unfinished basement, or a plex unit heated by its own furnace.

In these homes, the temptation is to go big "just to be safe." That is often a mistake. An oversized unit reaches the requested temperature in a few minutes, shuts off, then starts again. During those short cycles, the air does not stay on the coil long enough to leave its moisture behind, and the house feels damp even though the thermostat reads the right temperature.

That is why our first job is to calculate the real load before proposing this model. If the calculation points to a larger size, we will tell you plainly.

What the coil does in your plenum

The coil slides into the plenum, at the outlet of the furnace. Household air, pushed by the existing blower, passes through it. In summer, the refrigerant evaporates inside the tubes and absorbs heat from that air. The water that condenses is collected in a pan, then drained away through the 3/4 in SCH 40 drain.

In winter, if the outdoor unit is a heat pump, the cycle reverses. The refrigerant, warmed outdoors, gives up its heat to the air passing through the coil, and that same warm air travels through the same ducts as before. Nothing to cut into your walls.

The KCAC24FI in numbers

Here is what to keep in mind when comparing against a competing quote:

  • cabinet of 17-1/2 × 23 × 21-1/4 in, at 75 lb net, so it is easy to handle in a tight basement;
  • nominal airflow of 600 CFM, the lowest in the series;
  • 3/8 in liquid-side and 3/4 in suction-side connections;
  • EEV electronic expansion valve, which meters the refrigerant according to demand;
  • built-in R-32 leak sensor, with a service life of 15 years stated in the manual;
  • multipoise installation: upflow, downflow or horizontal, according to section 4.9 of the Kinghome manual.

The certified match with the KU36UXO

A coil on its own has no efficiency rating. The ratings belong to the coil and outdoor unit together. For the KCAC24FI with the KU36UXO, the AHRI number is 218046860. The published values for this system are:

  • cooling of 23,000 BTU/h;
  • heating of 24,000 BTU/h at 47 °F;
  • SEER2 16.0, HSPF2 8.5.

Always ask for this AHRI number on a quote: it is what lets you compare two offers on an honest basis and confirm eligibility for incentive programs.

Choosing between the KCAC24FI and its three neighbours

The KCAC series has four models, all on R-32, all with an EEV and a cabinet. They differ by size and width.

  • KCAC24FI: 2 tons, 17-1/2 in, paired with the KU36UXO. This is the model on this page.
  • KCAC36FI: 3 tons, the same 17-1/2 in width, the same KU36UXO unit. It fits when the load goes beyond that of a small home, without the furnace needing a different size.
  • KCAC48HI: 4 tons, 24-1/2 in, KU60UXO unit. Wider, for a wider furnace.
  • KCAC60HI: 5 tons, 24-1/2 in, KU60UXO unit, for very large homes.

The 2-ton and the 3-ton therefore share the same 17-1/2 in cabinet and the same outdoor unit. The difference lies in the airflow and in the capacity of the system, not in the space required.

The furnace stays, but its role changes

With a heat pump, the furnace keeps its blower, its filters and its heating elements. It becomes backup heat: we set up with you the outdoor temperature below which it takes over, for example during the deep cold of January.

An electric furnace turns every kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outside to inside; in mild temperatures, it delivers two to three times more heat than the electricity it uses. That efficiency drops as the cold deepens, which is why keeping the furnace as backup is useful.

A real-life home example

Take a suburban bungalow in Longueuil or Laval, with an electric furnace in the basement, double-pane windows replaced a few years ago and a window air conditioner in each bedroom. The owner wants to be done with the noise of window units, sleep better in July and cut the heating bill.

For this home, the 2-ton replaces the window units with a single outdoor unit and cool air from vents in every room. In winter, the heat pump handles most of the heating and the furnace starts only in the deepest cold. A single thermostat replaces everything else.

If the furnace is not the right width

The coil is 17-1/2 in wide. Most residential furnaces match that, but not all of them. When there is a gap, we measure on site and build an insulated transition between the furnace and the cabinet, then seal the joints to prevent air leaks.

We also check that the blower can deliver the airflow required. A blower that is too weak makes the coil freeze up or leaves some rooms poorly served.

How the installation goes

AirGreen is a family-run heating and cooling company that has been based in Montreal for more than fifteen years; our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this system, the sequence is as follows:

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the coil in the plenum, with a custom transition if needed, and sealing the connections;
  • setting the outdoor unit on a pad or bracket, brazed piping, nitrogen test and vacuum;
  • connecting the condensate drain and the thermostat;
  • commissioning, airflow adjustment and an explanation of how everything works, at your home.

Four checks before you buy

  • R-32 requires an outdoor unit using the same refrigerant, installed at the same time as the coil. An old air conditioner from a different generation does not connect to this coil.
  • The published ratings apply to the match with the KU36UXO, not to any other unit.
  • The 17-1/2 in width and the 600 CFM airflow must suit your furnace.
  • The manufacturer's warranty covers parts and the compressor: 7 years as standard, 12 years on a registered product, for residential use according to the Kinghome data sheets.

LogisVert incentive

The matched Kinghome system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation: we confirm it on the official list when we prepare your quote and we put the application together with you.

Request your estimate

Request your free on-site estimate. We measure the furnace, look at the electrical service and give you a written quote for the complete Kinghome system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The KCAC24FI sits in the plenum of a furnace or air handler. Connected to the Kinghome KU36UXO outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Kinghome KU36UXO outdoor unit
Certified systemMatched with the KU36UXO, the system carries AHRI 218046860.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerKinghome
ModelKCAC24FI
TypeCased evaporator coil
LineKCAC
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-32
Metering deviceEEV
Liquid connection3/8 in
Suction connection3/4 in
Airflow600 CFM
Dimensions W × H × D17-1/2 × 23 × 21-1/4 in
Net weight75 lb
Matched outdoor unitKU36UXO
System AHRI number218046860
System SEER2 / HSPF216.0 / 8.5
Model numberKCAC24FI
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
KINGHOME
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Kinghome coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom