LENNOX CK40HT-24B-71 Evaporator A-Coil | 2 Tons
The Lennox CK40HT-24B-71 2-ton R-454B cased coil sits on your furnace and, matched with the Lennox EL18KSLV-024-230A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCK40HT-24B-71
514 316-2973 · sales@airgreen.ca
Quick facts
Lennox CK40HT-24B-71: the 2-ton coil for wider furnaces, in a 17-1/2 in cabinet
Not every 2-ton coil fits every furnace. The CK40HT-24B-71 was designed for furnaces whose plenum is wider than average: its cabinet measures 17-1/2 in, against 14-1/2 in for the CK40HT-24A-71. For everything else, you get the same nominal capacity of 24,000 BTU/h, the R-454B refrigerant and the TXV.
If you live in Montreal, Laval, Longueuil, the North Shore or the South Shore, we can come and measure your furnace and tell you which of the two widths fits.
Why width matters so much
A cabinet too narrow for the plenum forces us to build a connecting piece. A cabinet too wide simply will not fit. Between the two, a perfect alignment gives a neater installation: fewer joints to seal, fewer air leaks around the coil, and air that passes through the whole exchange surface.
That is the reason for the B version. It changes neither the cooling capacity nor the piping, only the footprint of the cabinet: 17-1/2 in wide, or 444 × 673 mm according to the published dimensions.
Placing the 24B next to its siblings
- CK40HT-24A-71: same 2-ton capacity, same EL18KSLV-024-230A outdoor unit, 14-1/2 in cabinet;
- CK40HT-30B-71: 2.5 tons in the same 17-1/2 in size, with the EL18KSLV-036-230A outdoor unit;
- CK40HT-36B-71: 3 tons, same width, same outdoor unit as the 30B;
- CK40HT-18A-71: 1.5 tons, only offered in 14-1/2 in.
Remember the logic: in this series, you first choose the capacity from the house, then the letter from the furnace. The 24B is the "2 tons, wide furnace" combination.
The coil's role in your system
The coil is the part that exchanges heat with the air in the house. Installed in the plenum, it receives the refrigerant expanded by the TXV. In summer, this fluid absorbs heat from the passing air. The moisture condenses and leaves through the drain. With a heat pump, the direction is reversed during winter, and the heat drawn from outdoors is given up to the air in your home.
Pairing with the EL18KSLV-024-230A
The listing pairs this coil with the Lennox EL18KSLV-024-230A outdoor unit. Together, they form a system with AHRI number 216618928. That is the number to quote, not the one for the A version, when you compare quotes.
The coil shows no efficiency rating of its own. The published figures correspond to the coil plus outdoor unit pair.
Spec sheet to keep handy
- Model: Lennox CK40HT-24B-71, cased, CK40HT series;
- Nominal size: 2 tons, 24,000 BTU/h;
- Refrigerant and metering: R-454B, TXV;
- Footprint: 17-1/2 in wide;
- Liquid 3/8 in, suction 7/8 in;
- Condensate: 2 × 3/4 in FPT;
- Orientation: horizontal, with optional right-hand airflow using a 6 in spacer fabricated on site;
- Lennox basic limited warranty: 5 years on covered components in residential use, 1 year in non-residential use.
Leak detection: what R-454B changes at installation
An RDS sensor is factory-mounted on every coil in this series. If A2L refrigerant is detected, the compressor and the heating are locked out and the fan runs. It is a safety measure required with R-454B.
If the furnace has no RDS mitigation control, a board has to be ordered: the 27A03 (universal) or the 27A02 (24 V non-communicating). We spot this in advance by reading your unit's data plate.
How we work
The AirGreen team, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. On a project like this one:
- we measure the furnace, validate the blower and look at the electrical supply;
- we place the coil in the plenum and carefully seal all the connections;
- we install the outdoor unit, braze the lines, check for leaks with nitrogen and then pull a vacuum;
- we connect the drain and the thermostat;
- we start up the system, adjust the airflow and explain the settings to you.
Points to validate before ordering
- The outdoor unit must use the same refrigerant, R-454B.
- The furnace must offer the right space and blower; we confirm the 17-1/2 in cabinet at your place.
- The complete system sets the ratings and the eligibility for incentives.
Adding heating to cooling
The same equipment can work all year. In moderate weather, the heat pump supplies two to three times more heat than the electricity it uses, which no heating element alone can do. Efficiency decreases with the cold; the furnace then steps in, starting from a threshold that we set together.
Three situations where the B version is the one to pick
First case: replacing an old central air conditioner whose former coil sat in a wide plenum. The new cabinet has to follow its outline, otherwise we end up filling gaps with pieces of sheet metal.
Second case: converting an electric furnace to an "add-on" heat pump. These furnaces sometimes have a roomier cabinet than gas furnaces, and the 17-1/2 in width then makes perfect sense.
Third case: a project where you want to avoid a transition fabricated on site. It works well, but it adds sheet-metal work and joints to seal. If a cabinet of the right width exists, you might as well choose it.
What we measure during the visit
We do not rely on a photo of the data plate. We open up access, measure the plenum width, look at where the piping and the drain will run, then check the space available around the cabinet. We also note the condition of the blower and the thermostat settings.
These readings are used to write a quote that names the coil, the outdoor unit, the RDS board if any, and the electrical work needed. That way you know exactly what is included.
The TXV, in two sentences
The TXV is a thermostatic expansion valve: it regulates the amount of refrigerant entering the coil according to the load of the moment. This helps the exchanger use its whole surface, whether the day is mild or truly hot.
Two furnaces, two installations: an example
Take two neighbours on the same street with similar houses, both needing 2 tons. One has a furnace with a narrow plenum: his project is done with the CK40HT-24A-71, with no other fabrication. The other has a wider furnace: the CK40HT-24B-71 fits. The capacity, the piping and the outdoor unit are identical; only the box differs.
That is why we never sell a coil "from the catalogue" without having seen the furnace.
LogisVert incentive
The paired Lennox system is on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your personal situation; we check it against the official list at the time of the quote, then prepare the file with you.
Next step
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Lennox system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CK40HT-24B-71 sits in the plenum of a furnace or air handler. Connected to the Lennox EL18KSLV-024-230A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Lennox EL18KSLV-024-230A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
LENNOXSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Lennox coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.