MIDEA MAAHE-H24B-BA Evaporator A-Coil | 2 Tons

In stock

The Midea MAAHE-H24B-BA 2-ton R-454B cased coil sits on your furnace and, matched with the Midea MO1HE-H18B-2A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberMAAHE-H24B-BA

2 tons24,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 216623520
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberMAAHE-H24B-BA
ManufacturerMidea
Size2 tons
Width17-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unitMO1HE-H18B-2A

Midea MAAHE-H24B-BA, a cased 2-ton coil, 17-1/2 in wide: the right size for a wider furnace

When a small-capacity furnace has a plenum wider than average, a coil that is too narrow forces you to improvise the connections. That is exactly where the Midea MAAHE-H24B-BA makes the most sense: 2 tons of nominal capacity, but a cabinet 17-1/2 in wide.

Here, in question-and-answer form, is what a homeowner in Montreal, Laval, Longueuil, the North Shore or the South Shore usually wants to know before signing.

What exactly am I buying?

An evaporator coil housed in an insulated cabinet, from the EVOX G3 line. It mounts on an existing furnace or blower cabinet. In summer, the R-454B refrigerant flowing through its tubes absorbs heat from the house air. In winter, if the outdoor unit is a heat pump, the cycle reverses and the coil delivers the heat.

Which outdoor unit does it work with?

Midea publishes two matches:

  • MO1HE-H18B-2A, AHRI number 216623520: cooling 18,000 BTU/h, heating 19,000 BTU/h at 47 °F, SEER2 16.1, HSPF2 9.5;
  • MO1HE-H24B-2A, AHRI number 216623521: cooling 24,000 BTU/h, heating 25,000 BTU/h at 47 °F, SEER2 16.0, HSPF2 9.5.

Keep in mind that the ratings belong to the pairing of coil and outdoor unit. The coil alone has none. That AHRI number is also what rebate programs use.

Why 17-1/2 in rather than 14-1/2 in?

The twin model, the MAAHE-H24B-AA, offers the same capacity, the same refrigerant, the same TXV and the same outdoor units. It differs only in its 14-1/2 in width. The BA, for its part, covers furnaces with a wider plenum.

The rule is simple: choose the width closest to that of the furnace. If the gap is small, an insulated transition built on site settles the matter. If the gap is large, it is better to change models than to stretch a connection. We measure before ordering, never after.

The cabinet measurements

The MAAHE-H24B-BA measures 17-1/2 in wide by 18 in high and 21 in deep, or 445 × 533 × 457 mm. It weighs 42 lb net. The refrigerant connections are 3/8 in for the liquid line and 3/4 in for the suction line. The cabinet provides a primary drain and an auxiliary drain; the manufacturer does not publish their size.

Note that this 2-ton model weighs no more than its narrower twin: the difference lies in the width of the cabinet, not in its mass.

For which kind of home?

Think of a bungalow, a row house or one floor of a plex where the cooling load stays modest. A unit that is too large starts and stops in bursts: the air cools but stays humid, and you end up with a discomfort that no thermostat can fix. We assess the home's load first, then choose the equipment. If the result calls for three tons, the series offers models that are just as wide, such as the MAAHE-H36B-BA, also 17-1/2 in.

Can it heat?

Yes, provided it is matched with a heat pump. With a simple central air conditioner, it only cools. The "add-on" label means the furnace keeps its role: blower, filters and ductwork stay in place, and the furnace takes over below the outdoor temperature threshold that we set together.

The matched outdoor units are published to operate from -30 to 50 °C in cooling and from -30 to 24 °C in heating. Below -30 °C (-22 °F), the gas furnace takes over.

And what about safety with R-454B?

The coil contains a built-in leak detector with a 15-year service life. According to the service manual, it reacts at 10% of the LFL by starting the indoor fan. You have nothing to configure.

Can it be installed in a position other than upright?

Yes. Midea lists it as multi-position: upflow, downflow, horizontal left or right. A TXV metering device regulates the refrigerant flow according to the thermal load.

Can I keep my old air conditioner?

Generally, no. The old outdoor unit uses a different refrigerant, and the coil must be matched with the unit specified by the manufacturer. We install the complete system, which also lets you benefit from a consistent warranty.

What does this change on the bill and for comfort?

An electric furnace converts each kilowatt-hour into an equal amount of heat. A heat pump, on the other hand, carries heat that is already present outdoors, even in cool weather. In mild temperatures, it delivers two to three times more heat than the electricity it consumes. The colder it gets, the smaller that ratio becomes: that is why the furnace remains as backup.

In summer, a single system replaces window air conditioners. Cool air circulates to every room through the existing ducts, and the house dries out, which makes humid July days much easier to live with. One thermostat manages both seasons.

Where does the condensation water go?

When warm, humid air touches the cold fins, the moisture turns into water. It drops into the pan under the coil and flows out through the drain connection. The MAAHE-H24B-BA cabinet provides a primary drain and an auxiliary drain: the second protects you if the first becomes clogged. We run the drain to a compliant outlet and check the flow before we leave.

What does the warranty cover?

According to the 2025 Midea price list, the residential warranty includes 12 years on the compressor, 12 years on parts and 10 years of labour included, honoured by Descair. For commercial use, it is 5 years and 1 year.

How does installation with AirGreen work?

AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Our technician:

  • measures the furnace and reviews the blower and the electrical panel;
  • installs the coil in the plenum and seals the duct connections, with a custom transition if the width gap requires it;
  • mounts the outdoor unit on a pad or bracket, then brazes the piping;
  • pressure-tests with nitrogen and pulls the vacuum;
  • connects the condensate drain and the thermostat;
  • sets the airflow at commissioning and shows you how to use the system.

What to check before signing

  • The same refrigerant, R-454B, for the coil and the outdoor unit.
  • Plenum width compared with the 17-1/2 in of the cabinet.
  • The blower's ability to deliver the expected airflow.

Does the LogisVert rebate apply?

The matched Midea system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation. We validate it against the official list when we prepare your quote and put the application together with you.

And now?

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Midea system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The MAAHE-H24B-BA sits in the plenum of a furnace or air handler. Connected to the Midea MO1HE-H18B-2A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Midea MO1HE-H18B-2A outdoor unit
Certified systemMatched with the MO1HE-H18B-2A, the system carries AHRI 216623520.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerMidea
ModelMAAHE-H24B-BA
TypeCased evaporator coil
LineEVOX G3
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 × 18 × 21 in
Net weight42 lb
Matched outdoor unitMO1HE-H18B-2A, MO1HE-H24B-2A
System AHRI number216623520, 216623521
System SEER2 / HSPF216.1 / 9.5
Model numberMAAHE-H24B-BA
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
MIDEA
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Midea coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.