SAMSUNG HC48MBC021H1 Evaporator A-Coil | 4 Tons

In stock

The Samsung HC48MBC021H1 4-ton R-454B cased coil sits on your furnace and, matched with the Samsung AC036FCUPCG/AA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberHC48MBC021H1

4 tons48,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 218158141
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberHC48MBC021H1
ManufacturerSamsung
Size4 tons
Width21 in
RefrigerantR-454B
MeteringTXV
Outdoor unitAC036FCUPCG/AA

HC48MBC021H1: the 4-ton Samsung coil for two-storey homes and large bungalows

A two-storey house, a large bungalow with a finished basement, an enlarged cottage: in these buildings, the air has to travel long distances and pass through many rooms. The Samsung HC48MBC021H1 evaporator coil is designed for this kind of home. It offers 4 tons (48,000 BTU/h) in a 21 in cabinet, with R-454B refrigerant.

This is a cased A-coil from the Hylex line. It goes on the furnace and is paired with the Samsung AC036FCUPCG/AA outdoor unit. AirGreen installs it in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Airflow, the first criterion at this size

The more capacity goes up, the more air is needed for it to be really useful. At 4 tons, the coil and the blower are asked to do more than in a small house. If the blower does not deliver the required airflow, two things can happen: the coil freezes up, or the house lacks comfort despite a sturdy unit.

That is why we check the blower before even talking about price. We also look at the condition of the main ducts: a choked duct system does not let through the air the coil needs.

The 21 in width and the furnace

At this size, the coil’s width often increases, and it has to line up with that of the furnace. A narrower furnace can receive the coil with a transition; we build it and insulate it on site. The cabinet measures 21 × 27-1/2 × 21 in and weighs 53 lb: it takes two people to handle, but it goes in without special equipment.

The manufacturer lists multi-position installation: vertical, horizontal left or right. The metering device is a TXV.

The certified system and its published values

The pairing with the AC036FCUPCG/AA unit carries AHRI number 218158141. Here is what is published:

  • cooling: 34,000 BTU/h;
  • heating: 35,000 BTU/h at 47 °F;
  • system ratings, SEER2 / HSPF2: 16.0 / 8.5.

These values come from the complete system. The coil has no efficiency rating of its own, and it is the AHRI number that lets you compare two quotes honestly.

Where it stands among the other Samsung coils in the series

  • Same width, different capacity: the HC36MCC021H1 (3 tons) and the HC60MBC021H1 (5 tons) are also 21 in.
  • Less capacity: the 2-ton and 3-ton models (HC24MCB021H1, HC36MBB021H1) are 17-1/2 in wide.
  • More capacity and more width: the 5-ton HC60MAD021H1 and HC60MCD021H1 measure 24-1/2 in.
  • One common point: R-454B and a TXV metering device throughout.

If your home’s load calculation falls between two sizes, we would rather tell you so frankly than sell you the biggest unit.

Technical data

  • type: cased coil, model HC48MBC021H1;
  • nominal size: 4 tons (48,000 BTU/h);
  • connections: 3/8 in liquid and 7/8 in suction;
  • condensate drain: two 3/4 in female pipe thread (FPT) connections, at the front left and front right;
  • built-in R-454B leak detector, factory installed;
  • warranty: 10 years compressor, 10 years parts; registration required; conditions apply (Samsung quote).

The HA00A00203H1 mitigation controller is mandatory. It is sold separately and we include it in the quote.

What Samsung publishes for the 4-ton and 5-ton outdoor units

  • Hylex Premium: cooling from -20 to 50 °C, heating down to -25 °C;
  • 100% of nominal heating capacity at -10 °C for the 4-ton and 5-ton Premium models;
  • Hylex Standard: cooling from -20 to 50 °C, heating down to -25 °C; not ENERGY STAR certified;
  • inverter-driven twin rotary BLDC compressor, R-454B refrigerant;
  • piping: maximum length of 164 ft (50 m), maximum elevation difference of 98 ft (30 m).

A winter with a heat pump on a furnace

In a large house, the heating bill weighs heavily. An electric furnace turns each kilowatt-hour into an equal amount of heat; a heat pump moves heat from outdoors and delivers two to three times more than the electricity it consumes when the weather is mild. When the cold becomes intense, the furnace takes over, according to the threshold we set with you. The coil is the part that lets this heat pass into the duct air.

The homes where this size makes sense

Think of the two-storey cottage whose furnace blows upward through long ducts, the row townhouse with a finished basement, or the large bungalow built around a single central hallway. In each of these cases, a small capacity struggles to keep up; a 4-ton coil, well supplied with air, keeps a more even temperature from room to room.

Conversely, if the house is well insulated and of average size, a smaller size may be enough. We do the load calculation before recommending anything, because an oversized unit keeps shutting off and restarting and lets humidity settle in.

What we do with the piping

The 3/8 in liquid connection and the 7/8 in suction connection join the coil to the outdoor unit. The piping is brazed, insulated, then pressure-tested with nitrogen before the vacuum is pulled. This step may seem meticulous, but it is what keeps an R-454B circuit tight for years to come.

Our installation method

AirGreen is a family-run heating and cooling company in Montreal for more than fifteen years, holder of RBQ licence 5645-9605-01. On this system, we:

  • measure the furnace, test the blower and inspect the electrical panel;
  • install the cabinet on the plenum and seal the duct connections;
  • set the outdoor unit, braze the piping, test for leaks with nitrogen and pull a vacuum;
  • connect the condensate drain and the thermostat;
  • commission everything and adjust the airflow.

LogisVert rebate

The paired Samsung system appears on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list at the time of the quote and prepare the application with you.

After installation

We show you the filter, the drain and the thermostat, then leave a detailed quote that serves as a reference. If you have a doubt during the season, call us: it is better to check early than to wait for a breakdown.

Questions we are often asked

Can this coil provide heating? Yes, with a heat pump. With a central air conditioner, it only provides cooling.

Can I keep my current air conditioner? Generally no: R-454B requires the outdoor unit specified by the manufacturer. We install the complete system.

Is the furnace still useful? Yes, it keeps its blower and serves as backup in the coldest weather.

To confirm before ordering

  • The coil and the outdoor unit must share the same refrigerant.
  • The furnace width must be suitable, or a transition must be planned.
  • The blower must reach the system’s airflow.

A 4-ton Samsung coil, installed by AirGreen

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Samsung system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The HC48MBC021H1 sits in the plenum of a furnace or air handler. Connected to the Samsung AC036FCUPCG/AA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Samsung AC036FCUPCG/AA outdoor unit
Certified systemMatched with the AC036FCUPCG/AA, the system carries AHRI 218158141.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerSamsung
ModelHC48MBC021H1
TypeCased evaporator coil
LineHylex
Nominal size4 tons (48,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D21 × 27-1/2 × 21 in
Net weight53 lb
Matched outdoor unitAC036FCUPCG/AA
System AHRI number218158141
System SEER2 / HSPF216.0 / 8.5
Model numberHC48MBC021H1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
SAMSUNG
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton Samsung coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.