YORK CTF24A5ABS1 Evaporator A-Coil | 2 Tons

In stock

The York CTF24A5ABS1 2-ton R-454B cased coil sits on your furnace and, matched with a matching York outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTF24A5ABS1

2 tons24,000 BTU/h nominal
14-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTF24A5ABS1
ManufacturerYork
Size2 tons
Width14-1/2 in
RefrigerantR-454B
MeteringTXV

York CTF24A5ABS1: the narrow 14-1/2 in cased coil for a small furnace

When the furnace sits in a condo closet, in the basement of a plex or in the laundry room of a bungalow, every inch counts. York’s CTF24A5ABS1 is the narrower of the two 2-ton coils in the CTF series that we offer: 14-1/2 in wide, in an insulated cabinet that sits directly on top of the furnace. It runs on R-454B and can both cool and heat, depending on the outdoor unit it is paired with.

AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

What this coil does, in a few words

An evaporator coil is the heat exchanger placed in the furnace’s airstream. Refrigerant arrives from the outdoor unit, evaporates inside it and absorbs heat from the air passing through. The result is that the air coming out of the vents is cooler and drier.

With a heat pump, the circuit can also run in reverse in winter. With a plain central air conditioner, it only does the cooling. It is the same part, but not the same use.

Why 14-1/2 in changes the technical visit

A cabinet has to fit the top of the furnace. If it is wider, it overhangs; if it is narrower, air goes around the coil and some of the heat is never exchanged. Here, the 14-1/2 in width matches small furnaces, the kind found in townhouses and compact apartments.

So we measure the furnace before ordering. If the gap is small, we build an insulated transition on site. The cabinet measures 14-1/2 × 21-5/8 in and weighs 33 lb, which is still easy to handle in a tight space.

What you have at home before and after

  • Before: an electric furnace or an old central air conditioner, sometimes only window units.
  • After: a matched York outdoor unit, a coil in the plenum, and the same air ductwork as before.
  • The existing blower, filters and ducts are kept.

There is nothing to drill through the walls to distribute the air: it all already travels through the home’s ducts. That is the main argument for an installation on an existing furnace.

A word on the A shape

The coil is an A-coil: two sloped faces that meet at the top. Air rises through the centre and passes through both faces. The positions published by the manufacturer are upflow or downflow, which gives some flexibility depending on the direction your furnace moves air.

The metering device is a TXV. It doses the refrigerant sent into the coil according to the actual load, instead of letting a fixed flow through.

CTF24A5ABS1 spec sheet

  • Series: York CTF, cased coil
  • Nominal size: 2 tons, or 24,000 BTU/h
  • Refrigerant: R-454B
  • Dimensions: 14-1/2 × 21-5/8 in (W × H)
  • Net weight: 33 lb
  • Connections: 3/8 in for the liquid line, 3/4 in for the suction line
  • Nominal airflow: 800 CFM
  • Warranty: 10-year limited parts warranty, as stated in the York brochure PUBL-8373-B-0324

Leak detection: the A2L sensor

R-454B is an A2L refrigerant, and the coil ships with what is needed to monitor it. A factory-installed sensor (code S) is fixed to the coil plate and connected to the RDS control board.

If the concentration exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan starts. York manual 6356510-UIM-C-0824 describes how this works. The CTF, CTM and CTU coils for R-454B include this sensor.

CTF24A5ABS1 or CTF24B5ABS1: how to choose

Both models have the same 2-ton size, the same refrigerant, the same TXV and the same warranty. The difference comes down to the size of the cabinet.

  • CTF24A5ABS1 (this page): 14-1/2 in wide.
  • CTF24B5ABS1: 17-1/2 in wide, for wider furnaces.

The right choice is the one that matches the width of your furnace. Choosing at random means building a larger transition. Our technician takes the measurement and makes the call on site.

Pairing with the outdoor unit

Technically speaking, the coil is not sold on its own: it forms a system with a York outdoor unit of the same capacity and the same refrigerant. Before ordering, we confirm the exact pairing and its AHRI number, so that the ratings we quote are the ones you will actually get.

Among other things, York publishes these reference points:

  • the YORK HH8 heat pump (LX series) on R-454B, with a variable-speed compressor, ENERGY STAR certified for Canada and the United States;
  • certified pairings with HH824E2S11, HH836E2S11, HH860E2S11 and HH860E2S12, depending on the coil;
  • airflow of about 350 to 450 CFM per ton of outdoor unit, with an external static pressure of 0.2 to 0.6 in w.c.;
  • a 3/8 in liquid line, with larger lines possibly required for long distances.

The coil has no efficiency rating on its own. The SEER2, EER2 and HSPF2 ratings belong to the matched system. The AHRI number is what lets you compare two quotes honestly.

Heat pump and furnace: who does what

In an add-on installation, the heat pump handles most of the heating season. The furnace stays on as backup and takes over when the outdoor temperature drops below the threshold that we set with you.

An electric furnace turns every kilowatt-hour into an equal amount of heat. A heat pump moves heat and delivers two to three times more than the electricity it uses in mild temperatures. The colder it gets, the lower that efficiency falls, which is why it makes sense to keep the furnace.

The right size for a small space

An oversized system runs in short cycles. It cools quickly but does not have time to dry the air, and the house stays damp in July. The 2-ton size suits townhouses, compact bungalows and plex units that have their own furnace.

We confirm the home’s load before proposing this size. If the calculation points to a different one, we tell you.

What to check before buying

  • R-454B requires an outdoor unit that uses the same refrigerant, installed at the same time. Keeping your old air conditioner is generally not possible.
  • The blower must deliver the system’s airflow.
  • The width of the furnace must be confirmed on site.
  • The published ratings apply to the certified pairing, not to the coil alone.

Hydro-Québec incentives

Eligibility depends on the complete system, never on the coil alone. We check Hydro-Québec’s official list according to the installation date and tell you what applies to your project.

Frequently asked questions

Can it heat? Yes, when it is paired with a heat pump. With a central air conditioner, it only does the cooling.

Is the furnace still useful? Yes, as backup heating for the coldest days.

Installation by AirGreen in Greater Montreal

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, operating under RBQ licence 5645-9605-01. For this coil and its outdoor unit, we take care of:

  • measuring the furnace and checking the blower and the electrical panel;
  • mounting the coil in the plenum, with a transition built on site if needed, and sealing the connections;
  • the outdoor unit on a pad or bracket, the brazed piping, the nitrogen pressure test and the evacuation;
  • the condensate drain and the thermostat;
  • commissioning, airflow adjustment and an explanation of how the system works.

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTF24A5ABS1 sits in the plenum of a furnace or air handler. Connected to a matching York outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching York outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTF24A5ABS1
TypeCased evaporator coil
LineCTF
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Airflow800 CFM
Dimensions W × H × D14-1/2 × 21-5/8 in
Net weight33 lb
Model numberCTF24A5ABS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 14-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.