YORK CTF30B5ACS1 Evaporator A-Coil | 2.5 Tons

In stock

The York CTF30B5ACS1 2.5-ton R-454B cased coil sits on your furnace and, matched with the York HH824E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTF30B5ACS1

2.5 tons30,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 214606477
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTF30B5ACS1
ManufacturerYork
Size2.5 tons
Width17-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unitHH824E2S11

AHRI 214606477: York's CTF30B5ACS1, a 17-1/2 in coil paired with the HH824E2S11

Among the York 2.5-ton coils, only one shows a published pairing with a specific outdoor unit in our listing: the CTF30B5ACS1. Matched with the HH824E2S11, it forms a system carrying AHRI number 214606477, with a SEER2 / HSPF2 of 15.2 / 8.5. These figures make the decision simpler for anyone who wants to compare quotes on equal terms.

AirGreen installs this system in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

What is an AHRI number for?

A coil is never rated on its own. The efficiency of a central system depends on the exact combination of the indoor coil and the outdoor unit, and AHRI assigns a number to each tested combination. When a contractor promises you ratings, ask for this number: it lets you find the official record in the directory and check that the figures are those of your equipment.

The same number is also useful for incentive programs, which rely on lists of systems, never on individual parts.

What the HH824E2S11 pairing says

Here is the published pairing for the CTF30B5ACS1:

  • outdoor unit HH824E2S11;
  • AHRI number 214606477;
  • cooling: 23,000 BTU/h;
  • heating: 23,000 BTU/h at 47 °F;
  • SEER2 / HSPF2: 15.2 / 8.5.

Note that the coil's nominal capacity is 2.5 tons (30,000 BTU/h), while the certified system shows 23,000 BTU/h at test conditions. These are two different ways of naming the size; the second is the one that counts for the real performance of the matched system.

Where this model sits in the series

The three 2.5-ton CTF coils share the same R-454B refrigerant and the same TXV. Only their width differs.

  • CTF30A5ADS1: 14-1/2 in, for the narrowest furnaces;
  • CTF30B5ACS1 (this one): 17-1/2 in, the middle width, with the published HH824E2S11 pairing;
  • CTF30C5ACS1: 21 in, for wide furnaces.

If your furnace has an outlet of about 17-1/2 in, this model fits without a transition. Otherwise, we prepare an insulated connecting piece on site; the decision is made after taking measurements, not before.

Dimensions and weight

The cabinet measures 17-1/2 in wide and 25-5/8 in high, and the net weight is 41 lb. The shape is that of an A, with two sloped faces that meet at the top, and the coil is installed in an upflow or downflow position.

The connections are 3/8 in for the liquid line and 3/4 in for the suction line. The nominal airflow is 1,000 CFM.

The coil in practice, season by season

In summer, the refrigerant vaporizes in the tubes, absorbs heat from the air passing through and dries it along the way. The condensate is carried off by the drain. In winter, if the outdoor unit is a heat pump, the direction of the cycle changes: the heat collected outside is released into the indoor air.

The furnace keeps its blower, its filters and its ductwork. It takes over only below an outdoor temperature that we set with you.

Protection against R-454B leaks

R-454B is an A2L class refrigerant. York therefore installs a sensor at the factory, mounted on the coil plate and connected to the RDS control board. Above 15% of the LFL, the compressor no longer receives a call and the indoor fan starts. The manufacturer's reference is manual 6356510-UIM-C-0824.

Warranty and summary sheet

  • model: York CTF30B5ACS1, cased coil, CTF line;
  • size: 2.5 tons, 30,000 BTU/h;
  • 10-year limited warranty on parts, per York brochure PUBL-8373-B-0324;
  • TXV, R-454B refrigerant.

LogisVert incentive

The matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it against the official list when we prepare your quote, then put the application together with you. We promise no amount before validating these two items.

Which furnace suits this coil?

The 17-1/2 in cabinet suits mid-width furnaces, the kind found in many homes on the South Shore and North Shore where the unit is a few decades old. We assume nothing: during the visit, we measure the outlet, the available height above it and the location of the drain.

The blower matters as much as the width. It must deliver the system's airflow, otherwise the coil freezes up or comfort suffers. When the blower is borderline, we tell you and propose the possible corrections.

Questions our customers often ask

Can this coil provide heat? Yes, with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.

Can I keep my current air conditioner? Generally not. The coil uses R-454B and must be paired with the outdoor unit specified by the manufacturer; we install the complete system.

Is it eligible for incentives? Eligibility depends on the matched system, not on the coil alone.

Why add a heat pump as backup for the furnace

Conventional electric heating turns each kilowatt-hour into one kilowatt-hour of heat, nothing more. A heat pump moves heat from outdoors: in mild weather, it delivers two to three times more than it consumes. The colder it gets, the less efficient it is, and the furnace then takes over.

The result: a single system for summer and winter, controlled by one thermostat.

Our work at your home

AirGreen is a family-run heating and cooling company in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01. For this system, we plan the following:

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the coil in the plenum and sealing the joints;
  • mounting the outdoor unit, brazing the piping, pressure testing with nitrogen and pulling a vacuum;
  • connecting the drain and the thermostat;
  • commissioning, airflow adjustment and a demonstration.

Points to confirm before signing

  • The outdoor unit must use R-454B, like the coil.
  • The SEER2 and HSPF2 ratings apply to the matched system, not to the coil itself.
  • The furnace must offer the necessary width and airflow.

Maintenance and follow-up after installation

Once the system is running, a few simple habits extend its service life: change the filter at regular intervals, keep the condensate drain clear and clear the area around the outdoor unit. We can also schedule a visit to check the coil, the connections and the leak sensor.

Keep your system's AHRI number with your papers. It will help if you sell the house, if you submit an incentive application or if another technician needs to identify exactly which parts were installed.

Our team remains available after commissioning to answer questions about the thermostat and the furnace takeover threshold.

Request your estimate

Request a free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTF30B5ACS1 sits in the plenum of a furnace or air handler. Connected to the York HH824E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the York HH824E2S11 outdoor unit
Certified systemMatched with the HH824E2S11, the system carries AHRI 214606477.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTF30B5ACS1
TypeCased evaporator coil
LineCTF
Nominal size2.5 tons (30,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Airflow1,000 CFM
Dimensions W × H × D17-1/2 × 25-5/8 in
Net weight41 lb
Matched outdoor unitHH824E2S11
System AHRI number214606477
System SEER2 / HSPF215.2 / 8.5
Model numberCTF30B5ACS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.