Floor Heating Thermostat HONEYWELL TH115-AF-GA/U | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: TH115-AF-GA/U

Renovating a bathroom with floor heating is a project that needs careful planning, and choosing the thermostat is part of it.

3,600 Wmax. at 240 V
Programmablebuilt-in schedule
3 yearsmanufacturer warranty
Programmable
Get my installed price 514 316-2973

Quick facts

Model numberTH115-AF-GA/U
ProgrammableYes
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty3 years

Renovating a bathroom with floor heating is a project that needs careful planning, and choosing the thermostat is part of it. The Honeywell TH115-AF-GA/U combines 7-day programming and a Class A 5 mA ground fault circuit interrupter (GFCI) with a test light in a single housing. This combination makes it one of the most complete thermostats in our selection for electric floor heating. You enjoy a warm floor when you need it, controlled energy use the rest of the time and built-in protection that watches over the installation, at 120 V as well as 240 V.

Programming and protection in one

The TH115-AF-GA controls electric floor heating at 120 V or 240 V, with a maximum load of 15 A resistive: 3600 W at 240 V or 1800 W at 120 V. Its switching is double-pole (DPST relay). The GFCI test light lets you check the protection, and it also signals current leaks. The thermostat is compatible with the Aube CT240/CT241 telephone controller and carries CSA approval (CAN/CSA-C828-06).

The floor sensor

For the control modes that take the floor into account, a 15 ft (4.6 m) AC112-01 floor sensor is required. We confirm it is included in your order, or in your floor if the floor is already installed, before planning the start-up. In a new installation, the sensor is placed between the heating elements before the floor covering goes down.

Control and operating modes

Three control modes are available: ambient, floor, or ambient with floor limits. The floor setpoint ranges from 5 to 40 °C and the room setpoint from 5 to 30 °C. For operation, the thermostat offers automatic (programmed), manual and vacation modes. It works in 15-minute heating cycles, suited to the thermal inertia of a floor. Early Start, temporary override and the end-of-season ON/OFF switch round out the package.

Technical specifications

  • Stage: 1 heating, electric floor heating
  • Voltage: 120/240 VAC, 60 Hz
  • Maximum load: 15 A resistive (3600 W at 240 V, 1800 W at 120 V); DPST double-pole relay
  • Protection: built-in Class A 5 mA GFCI with test light, which also signals leaks
  • 7-day programmable, 4 periods per day; automatic, manual and vacation modes
  • 3 control modes: ambient, floor or ambient with floor limits
  • Floor setpoint: 5 to 40 °C (40 to 104 °F); room setpoint: 5 to 30 °C (40 to 86 °F)
  • 15-minute heating cycles
  • Early Start; temporary override; end-of-season ON/OFF switch
  • Display: large backlit LCD
  • 15 ft (4.6 m) AC112-01 floor sensor required for floor modes
  • Compatible with the Aube CT240/CT241 telephone controller
  • Hardwired; CSA approval (CAN/CSA-C828-06); connectivity: none
  • Dimensions: 124 x 70 x 23 mm (4.9 x 2.8 x 0.9 in.)
  • Colour: white

How we proceed

In a bathroom or kitchen renovation, the thermostat is the last step of a floor heating system, but it is prepared from the start. The floor sensor has to be placed in the right spot, between the heating elements, before the ceramic tile or floor covering is laid. When we work on an existing floor, we check that the existing sensor is there and in good condition. The thermostat is then wired with the breaker off, after confirming there is no voltage and checking the load of the heating element. Start-up includes setting the mode and limits and an operating test.

A schedule designed for the floor

Floor heating takes time to reach its temperature, and Early Start takes that into account: heating begins early enough for the tile to be warm at the scheduled time. A typical schedule includes a comfort period when you wake up, a reduced temperature during the day, a return to comfort in the evening and a setback at night. Vacation mode holds an away temperature while you travel, and manual mode lets you suspend the program when needed. Our technicians set up the schedule with you and show you how to test the built-in protection.

Programming that works for you

During the long cold months, every hour spent heating an empty house at the full setpoint is energy spent for nothing. Programming corrects this habit effortlessly: you set day, away, return and night periods, and the thermostat takes care of the rest. The key is to choose reasonable differences. A moderate setback at night or during working hours is usually enough, and the house is comfortable again in time when the program is well thought out. Our technicians can set up a first schedule with you during installation.

GA, GB or non-programmable model

The TH115-AF-GA/U shares its housing, programming and 3600 W capacity with the TH115-AF-GB/U. The difference lies in the protection: a Class A 5 mA GFCI on the GA, 15 mA EGFPD protection on the GB. The choice between the two depends on the requirements of the heating element manufacturer and of the installation; our technicians tell you which one is right. For a non-programmable version with the same 5 mA protection, the TH114-AF-GA/U is available. For a 120 V circuit that is already protected, the TH115-AF-120S/U is an alternative.

Long-term tips

Respect the recommended temperature limits for your floor covering; wood floors and some laminates tolerate less heat than ceramic tile. Never drill into a heated floor without knowing where the heating elements are. Periodically test the built-in protection when your thermostat has it. Otherwise, wiping the housing with a dry cloth is enough. If you are planning a renovation, let our technicians know there is floor heating so they can take it into account.

Why go with AirGreen

A thermostat cannot be judged on its own: it depends on the unit it controls, the existing wiring and the way you live in the house. That is why our advisors start by asking simple questions about your heating system, the rooms that are hard to keep comfortable and your schedule. AirGreen Inc. is a family HVAC business founded in Montréal more than 15 years ago, holding an RBQ licence, that works in Montréal, Laval, Longueuil, the North Shore and the South Shore. Our technicians work cleanly, explain what they are doing and leave the installation labelled to make any future service easier. Our showroom in Boucherville is open to anyone who prefers to see and handle the products before deciding.

To replace your current control, contact AirGreen today for the sale of this model and its installation by our technicians, anywhere in Montréal, Laval, Longueuil, the North Shore and the South Shore. We check your installation, set an appointment and leave the thermostat programmed to your schedule.

01 · Key facts

Key facts: HONEYWELL TH115-AF-GA/U

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

TypeFloor heating thermostatHONEYWELL TH115-AF-GA/U
Power120/240 VAC, 60 HzVoltage
Capacity15 A resistiveMaximum load
Displaylarge backlit LCDDisplay
02 · Compatible?

Is the HONEYWELL TH115-AF-GA/U compatible with your heating?

Two steps, thirty seconds. The verdict takes your system and your wiring into account.

Full compatibility table

Heating systemVerdictWhy
Central heat pumpNoA central system is controlled in 24 V.
Dual energy (heat pump + furnace)NoDual energy is controlled in 24 V.
Electric furnaceNoA furnace is controlled in 24 V.
Gas or oil furnaceNoA furnace is controlled in 24 V.
Steam, gravity or hot waterNoA hydronic floor needs a hydronic control.
Baseboards, convectors, radiant ceilingDepends on the modelDepends on the model: some also control a resistive load. See the spec sheet.
Fan-forced heaterNoA fan-forced heater needs a thermostat rated for fans.
Electric floor heatingYesDesigned for electric floor heating, with a floor probe.
Wall or ducted mini-split heat pumpNoA wall heat pump is controlled by its own brand’s controller.
03 · Wiring

How a floor heating thermostat connects

Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.

04 · Try it

Try the HONEYWELL TH115-AF-GA/U before you buy

Raise the setpoint, change the mode: see how it responds.

05 · Your savings

How much good programming can save you

Set up your typical week. The math follows the rule published by Natural Resources Canada.

06 · Winter and rebates

Winter, Rate Flex D and rebates: what this thermostat changes

With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. A programmable thermostat does the work for you.

07 · Head to head

The HONEYWELL TH115-AF-GA/U or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

08 · The right choice

The right thermostat in three questions

If this model is not the right one for you, the page says so and shows you which one is.

09 · The system

Products that go with the HONEYWELL TH115-AF-GA/U

Parts named in its spec sheet that we sell and install.

10 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01CheckHeating cable, probe and circuit load.
  2. 02Shut-offBreaker shut off at the panel.
  3. 03MountingHeating cable and probe wiring, mounting.
  4. 04TestPower back on and floor check.
  5. 05SettingsFloor temperature limits, schedule, connection.
11 · Specifications

HONEYWELL TH115-AF-GA/U specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralStage1 heat, electric floor heating
ElectricalVoltage120/240 VAC, 60 Hz
ElectricalMaximum load15 A resistive (3600 W at 240 V, 1800 W at 120 V); DPST double-pole relay
ElectricalProtectionBuilt-in 5 mA Class A GFCI with test light, which also signals leaks
GeneralOther7-day programmable, 4 periods per day; automatic, manual and vacation modes
General3 control modesambient, floor or ambient with floor limits
GeneralFloor setpoint5 to 40 °C (40 to 104 °F); room setpoint: 5 to 30 °C (40 to 86 °F)
GeneralOther15-minute heating cycles
GeneralOtherEarly start; temporary override; end-of-season ON/OFF switch
Format and contentsDisplaylarge backlit LCD
GeneralOther15 ft (4.6 m) AC112-01 floor probe required for floor modes
GeneralOtherCompatible with the Aube CT240/CT241 telephone controller
GeneralOtherHardwired connection; CSA certification (CAN/CSA-C828-06); connectivity: none
Format and contentsDimensions124 x 70 x 23 mm (4.9 x 2.8 x 0.9 in.)
Format and contentsColourwhite
12 · Questions

Frequently asked questions about the HONEYWELL TH115-AF-GA/U

Short answers, no detours.

What load can it control?

Up to 3,600 W at 240 V (1,800 W at 120 V), per the manufacturer’s sheet.

Who installs it?

Our technicians: the circuit is shut off at the panel, the heater load is checked, then the thermostat is wired and tested.

Can it be controlled remotely?

Not directly: it has no built-in Wi-Fi.

What is the warranty?

3 years, per the manufacturer’s information.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.